Application of diamond microelectrodes for end-column electrochemical detection in capillary electrophoresis

被引:77
作者
Shin, DC [1 ]
Sarada, BV [1 ]
Tryk, DA [1 ]
Fujishima, A [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
关键词
D O I
10.1021/ac020513j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly boron-doped diamond microelectrodes were employed in an end-column electrochemical detector for capillary electrophoresis (CE). The diamond microline electrodes were fabricated from conducting diamond thin films (exposed surface area, 300 x 50 mum), and their analytical performance as CE detectors was evaluated in a laboratory-made CE installation. The CE-ED system exhibited high separation efficiency for the detection of several catecholamines, including dopamine (DA), norepinephrine (NE), and epinephrine (E), with excellent analytical performance, for example, 155 000 theoretical plates for DA. the diamond-based electrochemical detection system also displayed low detection limits (similar to20 nM for E at S/N = 3) and a highly reproducible current response with 10 repetitive injections of mixed analytes containing DA, NE, and E (each 50 muM), with relative standard deviations (RSD) of similar to5%. The performance of the diamond detector in CE was also evaluated in the detection of chlorinated phenols (CP). When compared to the carbon fiber microelectrode, the diamond electrode exhibited lower detection limits in an end-column CE detection resulting from very low noise levels and highly reproducible analyses without electrode polishing due to analyte fouling, which makes it possible to perform easier and more stable CE analysis.
引用
收藏
页码:530 / 534
页数:5
相关论文
共 39 条
[1]   CHARACTERIZATION OF FILAMENT-ASSISTED CHEMICAL VAPOR-DEPOSITION DIAMOND FILMS USING RAMAN-SPECTROSCOPY [J].
BUCKLEY, RG ;
MOUSTAKAS, TD ;
LING, Y ;
VARON, J .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (08) :3595-3599
[2]   Capillary electrophoresis and electrochemical detection with a conventional detector cell [J].
Durgbanshi, A ;
Kok, WT .
JOURNAL OF CHROMATOGRAPHY A, 1998, 798 (1-2) :289-296
[3]  
Ewing Andrew G., 1994, Analytical Chemistry, V66, P527
[4]   Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection [J].
Fermier, AM ;
Gostkowski, ML ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1661-1664
[5]  
FORSTER RJ, 1994, CHEM SOC REV, P289
[6]   Electroanalysis of dopamine and NADH at conductive diamond electrodes [J].
Fujishima, A ;
Rao, TN ;
Popa, E ;
Sarada, BV ;
Yagi, I ;
Tryk, DA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 473 (1-2) :179-185
[7]   Continuous separations with microfabricated electrophoresis-electrochemical array detection [J].
Gavin, PF ;
Ewing, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (37) :8932-8936
[8]   Capillary electrophoresis with an integrated on-capillary tubular detector based on a carbon sol-gel-derived platform [J].
Hua, L ;
Tan, SN .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4821-4825
[9]   Determination of monoamine transmitters and their metabolites by capillary electrophoresis with electrochemical detection [J].
Jin, W ;
Jin, LT ;
Shi, GY ;
Ye, JN .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :33-37
[10]  
Landers JP, 1997, HDB CAPILLARY ELECTR