A computationally efficient algorithm for online spectral analysis of beat-to-beat signals

被引:2
作者
Castiglioni, P [1 ]
Di Rienzo, M [1 ]
Yosh, H [1 ]
机构
[1] Ctr Bioingn Fond, Milan, Italy
来源
COMPUTERS IN CARDIOLOGY 2002, VOL 29 | 2002年 / 29卷
关键词
D O I
10.1109/CIC.2002.1166798
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new algorithm is proposed for the online Fourier analysis of unevenly sampled data. The method is based on the theoretical evaluation of the Fourier Transform of a function linearly interpolating the data, and does not require actual interpolation and re-sampling. The method is particularly suitable for the running evaluation of power spectra. In fact, when a new sample is available, the spectrum can be updated simply by performing calculations on the last sample, without the need to calculate the Fourier Transform again over the whole data record. Applications with simulated and real data show the capability of the algorithm to efficiently estimate the Fourier transform of unevenly sampled cardiovascular data, beat after beat.
引用
收藏
页码:417 / 420
页数:4
相关论文
共 50 条
  • [41] Beat-to-beat analysis of P waves in patient with atrial fibrillation history
    Corino, Valentina D. A.
    Censi, Federica
    Tesoro, Marianna
    Corazza, Ivan
    Reggiani, Elisa
    Boriani, Giuseppe
    Mainardi, Luca T.
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 685 - 688
  • [42] Beat-to-beat analysis in ischemic preconditioning during angioplasty; effect of hypercholesterolemia
    Ungi, T
    Nagy, E
    Ruzsa, Z
    Zimmermann, Z
    Bencsik, P
    Csont, T
    Ungi, I
    Ferdinandy, P
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2004, 36 (05) : 765 - 765
  • [43] Beat-to-Beat Spatial and Temporal Analysis for QRS-T Morphology
    Hasan, Muhammad A.
    Abbott, Derek
    Baumert, Mathias
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4193 - 4195
  • [44] METHOD FOR ONLINE AUTOMATIC BEAT-TO-BEAT DIGITAL DISPLAY OF CARDIAC ACTION POTENTIAL DURATION
    WAXMAN, MB
    BERMAN, ND
    DOWNAR, E
    MENDLER, P
    MEDICAL & BIOLOGICAL ENGINEERING, 1976, 14 (02): : 136 - 140
  • [45] The acute effects of inhaled salbutamol on the beat-to-beat variability of heart rate and blood pressure assessed by spectral analysis
    Jartti, T
    Kaila, T
    Tahvanainen, K
    Kuusela, T
    Vanto, T
    Valimaki, I
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1997, 43 (04) : 421 - 428
  • [46] Beat-to-beat Analysis of the Relation between RT and RR Intervals in Newborns
    Patrick Pladys
    Lotfi Senhadji
    Pierre Maison Blanche
    Alain Beuchée
    Pierre Bétrémieux
    François Carré
    Journal of Perinatology, 2003, 23 (3) : 212 - 217
  • [47] HEART:: an automated beat-to-beat cardiovascular analysis package using Matlab®
    Schroeder, MJ
    Perreault, B
    Ewert, DL
    Koenig, SC
    COMPUTERS IN BIOLOGY AND MEDICINE, 2004, 34 (05) : 371 - 388
  • [48] Feasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis
    Matera, Lukas
    Sajgalik, Pavol
    Fabian, Vratislav
    Mikhailov, Yegor
    Zemanek, David
    Johnson, Bruce D.
    SENSORS, 2022, 22 (19)
  • [49] Continuous wavelet transform modulus maxima analysis of the electrocardiogram: Beat characterisation and beat-to-beat measurement
    Legarreta, IR
    Addison, PS
    Reed, MJ
    Grubb, N
    Clegg, GR
    Robertson, CE
    Watson, JN
    INTERNATIONAL JOURNAL OF WAVELETS MULTIRESOLUTION AND INFORMATION PROCESSING, 2005, 3 (01) : 19 - 42
  • [50] Quantitative beat-to-beat analysis of heart rate dynamics during exercise
    Tulppo, MP
    Makikallio, TH
    Takala, TES
    Seppanen, T
    Huikuri, HV
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 271 (01): : H244 - H252