The Formation and Utility of Sub-Angstrom to Nanometer-Sized Electron Probes in the Aberration-Corrected Transmission Electron Microscope at the University of Illinois

被引:28
作者
Wen, Jianguo [1 ]
Mabon, James [1 ]
Lei, Changhui [1 ]
Burdin, Steve [1 ]
Sammann, Ernie [1 ]
Petrov, Ivan [1 ]
Shah, Arnish B. [1 ,2 ]
Chobpattana, Varistha [1 ,2 ]
Zhang, Jiong [2 ]
Ran, Ke [2 ,3 ,4 ]
Zuo, Jian-Min [1 ,2 ]
Mishina, Satoshi [5 ]
Aoki, Toshihiro [5 ]
机构
[1] Univ Illinois, Frederick Seitz Mat Res Lab, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[3] Peking Univ, Key Lab Phys & Chem Nanodevices, Beijing 100871, Peoples R China
[4] Peking Univ, Dept Elect, Beijing 100871, Peoples R China
[5] JEOL USA Inc, Penbody, MA 01960 USA
关键词
aberration-corrected scanning transmission electron microscopy; high-angle annular dark-field imaging; electron energy loss spectroscopy; nanobeam diffraction; aperture nanobeam diffraction; PERFORMANCE;
D O I
10.1017/S1431927610000085
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We evaluate the probe forming capability of a JEOL 2200FS transmission electron microscope equipped with a spherical aberration (C-s) probe corrector. The achievement of a real space sub-Angstrom (0.1 nm) probe for scanning transmission electron microscopy (STEM) imaging is demonstrated by acquisition and modeling of high-angle annular dark-field STEM images. We show that by optimizing the illumination system, large probe currents and large collection angles for electron energy loss spectroscopy (EELS) can be combined to yield EELS fine structure data spatially resolved to the atomic scale. We demonstrate the probe forming flexibility provided by the additional lenses in the probe corrector in several ways, including the formation of nanometer-sized parallel beams for nanoarea electron diffraction, and the formation of focused probes for convergent beam electron diffraction with a range of convergence angles. The different probes that can be formed using the probe corrected STEM opens up new applications for electron microscopy and diffraction.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 25 条
[1]  
Allard L.F., 2005, MICROSC MICROANAL, V11, P2136
[2]   Sub-angstrom resolution using aberration corrected electron optics [J].
Batson, PE ;
Dellby, N ;
Krivanek, OL .
NATURE, 2002, 418 (6898) :617-620
[3]   Early results from an aberration-corrected JEOL 2200FS STEM/TEM at Oak Ridge National Laboratory [J].
Blom, Douglas A. ;
Allard, Lawrence F. ;
Mishina, Satoshi ;
O'Keefe, Michael A. .
MICROSCOPY AND MICROANALYSIS, 2006, 12 (06) :483-491
[4]   The Canadian Centre for Electron Microscopy: a national facility for ultrahigh resolution electron microscopy [J].
Botton, Gianluigi A. .
INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2008, 5 (9-12) :1082-1093
[5]   Electron nanodiffraction using sharply focused parallel probes [J].
Dwyer, Christian ;
Kirkland, Angus I. ;
Hartel, Peter ;
Mueller, Heiko ;
Haider, Maximilian .
APPLIED PHYSICS LETTERS, 2007, 90 (15)
[6]   Breaking the spherical and chromatic aberration barrier in transmission electron microscopy [J].
Freitag, B ;
Kujawa, S ;
Mul, PM ;
Ringnalda, J ;
Tiemeijer, PC .
ULTRAMICROSCOPY, 2005, 102 (03) :209-214
[7]   Upper limits for the residual aberrations of a high-resolution aberration-corrected STEM [J].
Haider, M ;
Uhlemann, S ;
Zach, J .
ULTRAMICROSCOPY, 2000, 81 (3-4) :163-175
[8]   Present and Future Hexapole Aberration Correctors for High-Resolution Electron Microscopy [J].
Haider, Maximilian ;
Mueller, Heiko ;
Uhlemann, Stephan .
ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 153, 2008, 153 :43-+
[9]  
Holmestad R., 2006, 16th International Microscopy Congress Sapporo, Japan, V2, P608
[10]   Coordination-dependent surface atomic contraction in nanocrystals revealed by coherent diffraction [J].
Huang, W. J. ;
Sun, R. ;
Tao, J. ;
Menard, L. D. ;
Nuzzo, R. G. ;
Zuo, J. M. .
NATURE MATERIALS, 2008, 7 (04) :308-313