Single step modification of copper electrode for the highly sensitive and selective non-enzymatic determination of glucose

被引:62
作者
Babu, T. G. Satheesh [1 ]
Ramachandran, T. [1 ]
Nair, Bipin [2 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Sci, Coimbatore 641105, Tamil Nadu, India
[2] Amrita Vishwa Vidyapeetham, Amrita Sch Biotechnol, Clappana, Kollam, India
关键词
Non-enzymatic glucose sensor; Copper oxide; Anodisation; Sodium potassium tartrate; ASCORBIC-ACID; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL OXIDATION; CARBOHYDRATE OXIDATION; POROUS GOLD; NANOPARTICLES; SENSOR; BIOSENSORS; SYSTEMS;
D O I
10.1007/s00604-010-0306-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-enzymatic sensor was developed for the determination of glucose in alkaline medium by anodisation of copper in sodium potassium tartrate solution. The morphology of the modified copper electrode was studied by scanning electron microscopy, and its electrochemical behavior by cyclic voltammetry and electrochemical impedance spectroscopy. The electrode enables direct electrocatalytic oxidation of glucose on a CuO/Cu electrode at 0.7 V in 0.1 M sodium hydroxide. At this potential, the sensor is highly selective to glucose even in the presence of ascorbic acid, uric acid, or dopamine which are common interfering species. The sensor displays a sensitivity of 761.9 mu A mM(-1) cm(-2), a linear detection range from 2 mu M to 20 mM, a response time of < 1 s, and a detection limit of 1 mu M (S/N = 3). It was tested for determination of glucose level in blood serum.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 44 条
[1]   Electrocatalytic oxidation of sugars on silver-UPD single crystal gold electrodes in alkaline solutions [J].
Aoun, SB ;
Bang, GS ;
Koga, T ;
Nonaka, Y ;
Sotomura, T ;
Taniguchi, I .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (04) :317-320
[2]   Nonenzymatic glucose detection with good selectivity against ascorbic acid on a highly porous gold electrode subjected to amalgamation treatment [J].
Cho, Sangeun ;
Kang, Chan .
ELECTROANALYSIS, 2007, 19 (22) :2315-2320
[3]   A nonenzymatic glucose sensor using nanoporous platinum electrodes prepared by electrochemical alloying/dealloying in a water-insensitive zinc chloride-1-ethyl-3-methylimidazolium chloride ionic liquid [J].
Chou, Chih-Hung ;
Chen, Jyh-Cheng ;
Tai, Chia-Cheng ;
Sun, I-Wen ;
Zen, Jyh-Myng .
ELECTROANALYSIS, 2008, 20 (07) :771-775
[4]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[5]   A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster/multiwall carbon nano tube-modified glassy carbon electrode [J].
Kang, Xinhuang ;
Mai, Zhibin ;
Zou, Xiaoyong ;
Cai, Peixiang ;
Mo, Jinyuan .
ANALYTICAL BIOCHEMISTRY, 2007, 363 (01) :143-150
[6]   ELECTROCATALYTIC OXIDATION OF CARBOHYDRATES AT COPPER(II)-MODIFIED ELECTRODES AND ITS APPLICATION TO FLOW-THROUGH DETECTION [J].
KANO, K ;
TORIMURA, M ;
ESAKA, Y ;
GOTO, M ;
UEDA, T .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 372 (1-2) :137-143
[7]   Electroanalytical and bioelectroanalytical systems based on metal and semiconductor nanoparticles [J].
Katz, E ;
Willner, I ;
Wang, J .
ELECTROANALYSIS, 2004, 16 (1-2) :19-44
[8]   Biosensors - a perspective [J].
Kissinger, PT .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2512-2516
[9]   Gold nanoparticles in nonenzymatic electrochemical detection of sugars [J].
Kurniawan, Fredy ;
Tsakova, Vessela ;
Mirsky, Vladimir M. .
ELECTROANALYSIS, 2006, 18 (19-20) :1937-1942
[10]   Preparation of carbon nanotubes supported platinum nanoparticles by an organic colloidal process for nonenzymatic glucose sensing [J].
Li, Li-Hua ;
Zhang, Wei-De .
MICROCHIMICA ACTA, 2008, 163 (3-4) :305-311