Motion compensated reconstructions of calcified coronary plaques in cardiac CT

被引:0
作者
King, Martin [1 ]
Pan, Xiaochuan [1 ]
Giger, Maryellen [1 ]
Suzuki, Kenji [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
来源
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2007年 / 6510卷
基金
美国国家卫生研究院;
关键词
computed tomography (CT); cardiac imaging; motion compensation;
D O I
10.1117/12.713798
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to obtain motion-compensated reconstructions of calcified coronary plaques in cardiac CT, the dynamic trajectory of the plaque must be known rather accurately. The purpose of this study is to evaluate whether the dynamic trajectories of a plaque extracted from reconstructions provided by a previously developed tracking algorithm can be used for obtaining motion-compensated reconstructions of this plaque. A single projection dataset of the modified FORBILD phantom containing a calcified plaque undergoing continuous periodic motion was acquired with a gantry rotation time of 0.4 s and a heart rate of 90 bpm. Three sets of phase-correlated 4D ROI images centered on the calcified plaque (labeled G1, G2, and G3) were obtained from this dataset by varying the numbers of data segments used for cardiac gating (N = 1, 2, 3) during the reconstruction steps of the tracking algorithm. Dynamic trajectories from each of these datasets were calculated from edge-based segmentations of these datasets. When compared to the true trajectory (labeled T), root-mean-square (RMS) values of position for trajectories G1, G2, and G3 were 1.473 mm, 1.166 mm, and 0.736 mm, respectively. Trajectories G1, G2, G3, and T then were used to obtain motion-compensated reconstructions MC1, MC2, MC3, and MCT, respectively, at 6.25 ms time intervals over 2 cardiac cycles. The areas (number of pixels) of the plaque then were measured at all time intervals for each set of reconstructions. When compared against areas obtained for MCT, RMS values of areas for reconstructions MC1, MC2, and MC3 were 26.888, 12.384, and 4.837, respectively. On visual inspection, MC3 also exhibited the least motion artifacts at most time intervals.
引用
收藏
页数:6
相关论文
共 17 条
  • [1] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [2] Respiratory compensation in projection imaging using a magnification and displacement model
    Crawford, CR
    King, KF
    Ritchie, CJ
    Godwin, JD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) : 327 - 332
  • [3] Present status and future potential of multislice computed tomography
    Flohr T.
    Ohnesorge B.
    Schaller S.
    [J]. Der Radiologe, 2004, 44 (2): : 113 - 120
  • [4] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [5] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [6] Technical advances in multi-slice spiral CT
    Fuchs, T
    Kachelriess, M
    Kalender, WA
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 69 - 73
  • [7] Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model
    Grangeat, P
    Koenig, A
    Rodet, T
    Bonnet, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15) : 2611 - 2625
  • [8] Kachelriess M, 2000, IEEE T MED IMAGING, V19, P888, DOI 10.1109/42.887837
  • [9] ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    Kachelriess, M
    Ulzheimer, S
    Kalender, WA
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1881 - 1902
  • [10] KING M, 2006, C REC 2006 IEEE NUCL