Ion chromatography for rapid and sensitive determination of fluoride in milk after headspace single-drop microextraction with in situ generation of volatile hydrogen fluoride

被引:85
作者
Hang Yiping [1 ]
Wu Caiyun [1 ]
机构
[1] S China Univ Technol, Sch Chem & Chem Engn, Guangzhou 510640, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Headspace; Single-drop microextraction; Ion chromatography; Fluoride; Milk; LIQUID-PHASE MICROEXTRACTION; AQUEOUS SAMPLES; DRINKING-WATER; FLUOROMETRIC-DETERMINATION; SPECTROMETRY; SOLVENT; EXTRACTION; FUSION; FLAME;
D O I
10.1016/j.aca.2009.12.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, we report a new method that involves headspace single-drop microextraction and ion chromatography for the preconcentration and determination of fluoride. The method lies in the in situ hydrogen fluoride generation and subsequent sequestration into an alkaline microdrop, (15 mu L) exposed to the headspace above the stirred aqueous sample. The NaF formed in the drop was then determined by ion chromatography. The influences of some crucial single-drop microextraction parameters such as the extraction temperature, extraction time, sample stirring speed, sulphuric acid concentration and ionic strength of the sample, on extraction efficiency were investigated. In the optimal condition, an enrichment factor of 97 was achieved in 15 min. The calibration working range was from 10 mu g L-1 to 2000 mu g L-1 (R-2 = 0.998), and the limit of detection (signal to noise ratio of 3) was 3.8 mu g L-1 of fluoride. Finally, the proposed method was successfully applied to the determination of fluoride in different milk samples. The recoveries of fluoride (at spiked concentrations of 200 mu g L-1 and 600 mu g L-1 into milk) in real samples ranged from 96.9% to 107.7%. Intra-day precision (N = 3) in terms of peak area, expressed as relative standard deviation, was found to be within the range of 0.24-1.02%. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 35 条
[21]   Colorimetric determination of sulfur dioxide in air using a droplet collector of malachite green solution [J].
Milani, MR ;
Neto, JAC ;
Cardoso, AA .
MICROCHEMICAL JOURNAL, 1999, 62 (02) :273-281
[22]   Indicator tubes and indicator powders for determining fluoride and chloride ions [J].
Morosanova, EI ;
Velikorodnyi, AA ;
Myshlyakova, OV ;
Zolotov, YA .
JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (03) :284-289
[23]   Solvent extraction and fluorometric determination of fluoride ion at ppb level in the presence of large excess of aluminum(III) and iron(III) by using an expanded porphyrin, sapphyrin [J].
Nishimoto, J ;
Yamada, T ;
Tabata, M .
ANALYTICA CHIMICA ACTA, 2001, 428 (02) :201-208
[24]   Determination of fluorine in aqueous samples by electrothermal vaporisation inductively coupled plasma mass spectrometry (ETV-ICP-MS) [J].
Okamoto, Y .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) :539-541
[25]   Simultaneous determination of potassium and total fluoride in toothpastes using a SIA system with two potentiometric detectors [J].
Perez-Olmos, R. ;
Soto, J. C. ;
Zarate, N. ;
Diez, I. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (01) :170-176
[26]   Colorimetric determination of formaldehyde in air using a hanging drop of chromotropic acid [J].
Pretto, A ;
Milani, MR ;
Cardoso, AA .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (06) :566-570
[27]  
Psillakis E, 2002, TRAC-TREND ANAL CHEM, V21, P53
[28]   High concentrations of fluoride and boron in drinking water wells in the Muenster region - Results of a preliminary investigation [J].
Queste, A ;
Lacombe, M ;
Hellmeier, W ;
Hillermann, F ;
Bortulussi, B ;
Kaup, M ;
Ott, K ;
Mathys, W .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2001, 203 (03) :221-224
[30]  
STEFAN RI, 1999, ACTA HELV, V73, P307