Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study

被引:26
|
作者
Gumrukcu, Zeynep [1 ]
Korkmaz, Yavuz Tolga [1 ]
Korkmaz, Fatih Mehmet [2 ]
机构
[1] Fac Dent, Dept Oral & Maxillofacial Surg, Trabzon, Turkey
[2] Fac Dent, Dept Prosthodont, Trabzon, Turkey
关键词
Sinus augmentation; Tilted implant; Stress analysis; Bone type; Von Mises stress; SHORT DENTAL IMPLANTS; RETAINED OVERDENTURES; STRESS-DISTRIBUTION; CORTICAL BONE; LENGTH; STABILITY; QUALITY; THICKNESS; DIAMETER; SURVIVAL;
D O I
10.1016/j.compbiomed.2017.04.015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and Objective: The purpose of this study is to evaluate and compare bone stress that occurs as a result of using vertical implants with simultaneous sinus augmentation with bone stress generated from oblique implants without sinus augmentation in atrophic maxilla. Methods: Six, three-dimensional (3D) finite element (FE) models of atrophic maxilla were generated with SolidWorks software. The maxilla models were varied for two different bone types. Models 2a, 2b and 2c represent maxilla models with D2 bone type. Models 3a, 3b and 3c represent maxilla models with D3 bone type. Five implants were embedded in each model with different configurations for vertical implant insertion with sinus augmentation: Model 2a/Model 3a, 30 degrees tilted insertion; Model 2b/Model 3b and 45 degrees tilted insertion; Model 2c/Model 3c. A 150 N load was applied obliquely on the hybrid prosthesis. The maximum von Mises stress values were comparatively evaluated using color scales. Results: The von Mises stress values predicted by the FE models were higher for all D3 bone models in both cortical and cancellous bone. For the vertical implant models, lower stress values were found in cortical bone. Tilting of the distal implants by 30 degrees increased the stress in the cortical layer compared to vertical implant models. Tilting of the distal implant by 45 degrees decreased the stress in the cortical bone compared to the 30 degrees models, but higher stress values were detected in the 45 degrees models compared to the vertical implant models. Conclusions: Augmentation should be the first treatment option in atrophic maxilla in terms of biomechanics. Tilted posterior implants can create higher stress values than vertical posterior implants. During tilting implant planning, the use of a 45 degrees tilted implant results in better biomechanical performance in peri-implant bone than 30 degrees tilted implant due to the decrease in cantilever length.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [21] Biomechanical analysis of the effects of implant diameter and bone quality in short implants placed in the atrophic posterior maxilla
    Chang, Shih-Hao
    Lin, Chun-Li
    Hsue, Shue-Sang
    Lin, Yang-Sung
    Huang, Shiang-Rung
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (02) : 153 - 160
  • [22] Rehabilitation of Atrophied Low-Density Posterior Maxilla by Implant-Supported Prosthesis
    Anitua, Eduardo
    Pinas, Laura
    Murias-Freijo, Alia
    Alkhraisat, Mohammad Hamdan
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (01) : E1 - E2
  • [23] Prognosis of implant longevity in terms of annual bone loss: a methodological finite element study
    Demenko, Vladyslav
    Linetskiy, Igor
    Linetska, Larysa
    Nesvit, Vitalij
    Shevchenko, Andrii
    Yefremov, Oleg
    Weisskircher, Hans-Werner
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (02) : 180 - 187
  • [24] Implant-supported overdenture with horizontal insertion for treating the edentulous atrophic maxilla: A case series
    Agustin-Panadero, Ruben
    Manes-Ferrer, Jose Felix
    Bustamante-Hernandez, Naia
    Sola-Ruiz, Maria Fernanda
    Fons-Badal, Carla
    Fernandez-Estevan, Lucia
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 942 - 948
  • [25] BIOMECHANICAL EVALUATION OF SCREW- AND CEMENT-RETAINED IMPLANT-SUPPORTED PROSTHESES: A NONLINEAR FINITE ELEMENT ANALYSIS
    Silva, Guilherme Carvalho
    Cornacchia, Tulimar Machado
    de Magalhaes, Claudia Silami
    Bueno, Audrey Cristina
    Moreira, Allyson Nogueira
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06): : 1479 - 1488
  • [26] The Influence of Various Superstructure Materials on Stress Distribution for Implant-Supported Prosthesis: Three-Dimensional Finite Element Analysis
    Jameel, Rawan Mufeed
    Al-Khafaji, Aseel Mohammed
    PROSTHESIS, 2024, 6 (05): : 1133 - 1148
  • [27] Effect of implant placement depth on bone remodeling on implant-supported single zirconia abutment crown: A 3D finite element study
    Poovarodom, Pongsakorn
    Rungsiyakull, Chaiy
    Suriyawanakul, Jarupol
    Li, Qing
    Sasaki, Keiichi
    Yoda, Nobuhiro
    Rungsiyakull, Pimduen
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (02) : 278 - 287
  • [28] Comparison of the Crestal Bone Loss Between Implant-Supported Prosthesis With Sinus Augmentation and Distal Cantilevered Implant-Supported Prosthesis Without Sinus Augmentation
    Dereci, Omur
    Mumcu, Emre
    Kosar, Yasin Caglar
    Fadhil, Sadeq Mohammed Taqi
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (05) : 401 - 406
  • [29] Biomechanical behavior of titanium, cobalt-chromium, zirconia, and PEEK frameworks in implant-supported prostheses: a dynamic finite element analysis
    Hazir, Dilara Sahin
    Yanik, Irem Sozen
    Guncu, M. Baris
    Canay, R. Senay
    BMC ORAL HEALTH, 2025, 25 (01):
  • [30] Biomechanical behavior of cantilevered 3-unit implant-supported prostheses made of PEKK and monolithic zirconia: A finite element study
    Sadek, Hatem S.
    Anany, Noha M.
    El-Anwar, Mohamed I.
    Alhotan, Abdulaziz
    Diab, Al-Hassan
    Aldesoki, Mostafa
    Elshazly, Tarek M.
    Bourauel, Christoph
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2025, 163