Measuring Heart Rate Variability Using Facial Video

被引:9
|
作者
Martinez-Delgado, Gerardo H. [1 ]
Correa-Balan, Alfredo J. [1 ]
May-Chan, Jose A. [1 ]
Parra-Elizondo, Carlos E. [1 ]
Guzman-Rangel, Luis A. [2 ]
Martinez-Torteya, Antonio [3 ]
机构
[1] Univ Monterrey, Programa Ingn Mecatron, San Pedro Garza Garcia 66238, Mexico
[2] Univ Monterrey, Programa Maestria Ingn Producto, San Pedro Garza Garcia 66238, Mexico
[3] Univ Monterrey, Escuela Ingn & Tecnol, San Pedro Garza Garcia 66238, Mexico
关键词
Photoplethysmography (PPG); heart rate measurement; Heart Rate Variability (HRV); non-contact; face imaging; SPECTRAL-ANALYSIS; NONCONTACT; MODELS; PPG;
D O I
10.3390/s22134690
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart Rate Variability (HRV) has become an important risk assessment tool when diagnosing illnesses related to heart health. HRV is typically measured with an electrocardiogram; however, there are multiple studies that use Photoplethysmography (PPG) instead. Measuring HRV with video is beneficial as a non-invasive, hands-free alternative and represents a more accessible approach. We developed a methodology to extract HRV from video based on face detection algorithms and color augmentation. We applied this methodology to 45 samples. Signals obtained from PPG and video recorded an average mean error of less than 1 bpm when measuring the heart rate of all subjects. Furthermore, utilizing PPG and video, we computed 61 variables related to HRV. We compared each of them with three correlation metrics (i.e., Kendall, Pearson, and Spearman), adjusting them for multiple comparisons with the Benjamini-Hochberg method to control the false discovery rate and to retrieve the q-value when considering statistical significance lower than 0.5. Using these methods, we found significant correlations for 38 variables (e.g., Heart Rate, 0.991; Mean NN Interval, 0.990; and NN Interval Count, 0.955) using time-domain, frequency-domain, and non-linear methods.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Video Based Measurement of Heart Rate and Heart Rate Variability Spectrogram from Estimated Hemoglobin Information
    Fukunishi, Munenori
    Kurita, Kouki
    Yamamoto, Shoji
    Tsumura, Norimichi
    PROCEEDINGS 2018 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS (CVPRW), 2018, : 1405 - 1412
  • [42] Relationships between heart-rate variability and pulse-rate variability obtained from video-PPG signal using ZCA
    Iozzia, Luca
    Cerina, Luca
    Mainardi, Luca
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (11) : 1934 - 1944
  • [43] Analysis on Human Heart Signal during Sad Video Stimuli using Heart Rate Variability Triangular Index (HRVi)
    Rumpa, Lantana Dioren
    Wibawa, Adhi Dharma
    Attamimi, Muhammad
    Sampelawang, Petrus
    Purnomo, Mauridhi Hery
    Palelleng, Srivan
    2018 INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING, NETWORK AND INTELLIGENT MULTIMEDIA (CENIM), 2018, : 25 - 28
  • [44] Validation of a Polar® human heart rate monitor for measuring heart rate and heart rate variability in adult dogs under stationary conditions
    Jonckheer-Sheehy, Valerie S. M.
    Vinke, Claudia M.
    Ortolani, Alessia
    JOURNAL OF VETERINARY BEHAVIOR-CLINICAL APPLICATIONS AND RESEARCH, 2012, 7 (04) : 205 - 212
  • [45] PROBLEMS IN MEASURING HEART-RATE-VARIABILITY OF PATIENTS WITH CONGESTIVE-HEART-FAILURE
    MYERS, G
    WORKMAN, M
    BIRKETT, C
    FERGUSON, D
    KIENZLE, M
    JOURNAL OF ELECTROCARDIOLOGY, 1993, 25 : 214 - 219
  • [46] Spectral Features of Heart Rate Variability Obtained from a Video Camera
    Caglayan, Ece
    Ozkurt, Tolga Esat
    2015 23RD SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2015, : 955 - 957
  • [47] Detection of asphyxia using heart rate variability
    Boardman, A
    Schlindwein, FS
    Thakor, NV
    Kimura, T
    Geocadin, RG
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (06) : 618 - 624
  • [48] Drowsiness detection using heart rate variability
    Vicente, Jose
    Laguna, Pablo
    Bartra, Ariadna
    Bailon, Raquel
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (06) : 927 - 937
  • [49] Drowsiness detection using heart rate variability
    José Vicente
    Pablo Laguna
    Ariadna Bartra
    Raquel Bailón
    Medical & Biological Engineering & Computing, 2016, 54 : 927 - 937
  • [50] Detection of asphyxia using heart rate variability
    A. Boardman
    F. S. Schlindwein
    N. V. Thakor
    T. Kimura
    R. G. Geocadin
    Medical and Biological Engineering and Computing, 2002, 40 : 618 - 624