Defining segments and phases of a time capnogram

被引:32
作者
Bhavani-Shankar, K [1 ]
Philip, JH [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Anesthesiol Perioperat & Pain Med, Boston, MA USA
关键词
D O I
10.1097/00000539-200010000-00038
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The division of a time capnogram into inspiratory and expiratory segments is arbitrary and results in the inability of a time capnogram to detect rebreathing instantaneously. Demarcation of a time capnogram into inspiratory and expiratory components using gas flow signals will not only facilitate prompt detection of rebreathing, but will also allow application of standardized and physiologically appropriate nomenclature for better understanding and interpretation of time capnograms. A Novametrix(R) CO2-SMO plus respiratory profile monitor (Novametrix Medical Systems, Wallingford, CT) was used to obtain a simultaneous display of CO2 and respiratory flow waveforms on a computer screen during spontaneous and controlled ventilation using a circle system with the inspiratory valve competent (no rebreathing) and with the valve displaced (rebreathing). Because the response time of the CO2 analyzer was similar to the response time of the flow sensor, a comparison was made between the two waveforms to determine the inspiratory segment (Phase 0) and the expiratory segment of the time capnogram and its subdivisions (Phases I, II, and III). The end of expiration almost coincides with the downslope of the CO2 waveform in the capnograms when there is no rebreathing. However, in the presence of rebreathing, the alveolar plateau is prolonged and includes a part of inspiration (Phase 0), in addition to the expiratory alveolar plateau (Phase III).
引用
收藏
页码:973 / 977
页数:5
相关论文
共 14 条
[1]  
Adams AP, 1989, RECENT ADV ANAESTHES, P155
[2]   TERMINOLOGY AND THE CURRENT LIMITATIONS OF TIME CAPNOGRAPHY - A BRIEF REVIEW [J].
BHAVANISHANKAR, K ;
KUMAR, AY ;
MOSELEY, HSL ;
AHYEEHALLSWORTH, R .
JOURNAL OF CLINICAL MONITORING, 1995, 11 (03) :175-182
[3]   CAPNOMETRY AND ANESTHESIA [J].
BHAVANISHANKAR, K ;
MOSELEY, H ;
KUMAR, AY ;
DELPH, Y .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (06) :617-632
[4]  
Breen PH, 1997, ANESTH ANALG, V85, P1372
[5]  
Curley M A, 1990, Pediatr Nurs, V16, P397
[6]   DEADSPACE AND THE SINGLE BREATH TEST FOR CARBON-DIOXIDE DURING ANESTHESIA AND ARTIFICIAL-VENTILATION [J].
FLETCHER, R ;
JONSON, B .
BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (02) :109-119
[7]  
GOOD ML, 1993, ANESTHESIA EQUIPMENT, P237
[8]  
HARDWICK M, 1990, CURR ANAESTH CRIT CA, V3, P176
[9]  
KALENDA Z, 1989, MASTERING INFRARED C, P101
[10]   INSPIRATORY VALVE MALFUNCTION IN A CIRCLE SYSTEM - PITFALLS IN CAPNOGRAPHY [J].
KUMAR, AY ;
BHAVANISHANKAR, K ;
MOSELEY, HSL ;
DELPH, Y .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (09) :997-999