Method development for the analysis of total bacterial count in raw milk using near-infrared spectroscopy

被引:13
作者
Numthuam, Sonthaya [1 ]
Hongpathong, Jutaporn [1 ]
Charoensook, Rangsun [1 ,2 ]
Rungchang, Saowaluk [1 ]
机构
[1] Naresuan Univ, Fac Agr Nat Resources & Environm, Mueang 65000, Phitsanulok, Thailand
[2] Naresuan Univ, Ctr Agr Biotechnol, Mueang 65000, Phitsanulok, Thailand
关键词
raw milk; total bacteria; near-infrared; rapid method; dairy safety; SOMATIC-CELL COUNT; RAPID-DETERMINATION; CONTAMINATION; PREDICTION; FAT; QUALITY; PROTEIN; CHEESE;
D O I
10.1111/jfs.12335
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The possibility use of near-infrared (NIR) spectroscopy in the region of 9000-4000 cm(-1) to determine total bacterial count (TBC) in raw milk and the influence of bacterial cultivation on TBC prediction accuracy were studied. Raw milk samples were diluted 10-fold with tryptic soy broth and then cultivated at 32 degrees C for 2 hr. NIR measurements were performed after cultivation times of 30, 60, 90, and 120 min. Partial least squares regression was used to develop calibration models for TBC. The best calibration result was obtained from the 90 min-cultivation samples, with the correlation coefficient (R) of .90 and root mean square error of prediction of .32 log(10) CFU/ml. The analysis of the calibration structure indicated that important information for TBC prediction was from chemical compositional changes and bacterial metabolites. The NIR method combined with bacterial cultivation was satisfactory for the rapid analysis of TBC in raw milk. Practical applicationsThe number of bacteria in raw milk is an important indicator for hygienic quality and milk grading system which consequently reflects a milk price. The proposed method allows satisfied performance for TBC determination in raw milk in 90 min as compared to the 48 hr required using the plate count method. The NIR method developed in this study seems to be an effective tool for a rapid evaluation of bacterial contamination in raw milk. An integration between determination of milk hygienic quality and chemical compositional quality using NIR spectroscopy will facilitate a rapid and multicomponents analysis and become a powerful tool for a practical use in the competitive dairy industry.
引用
收藏
页数:7
相关论文
共 34 条
[1]   Monitoring quality loss of pasteurized skim milk using visible and short wavelength near-infrared spectroscopy and multivariate analysis [J].
Al-Qadiri, H. M. ;
Lin, M. ;
Al-Holy, M. A. ;
Cavinato, A. G. ;
Rasco, B. A. .
JOURNAL OF DAIRY SCIENCE, 2008, 91 (03) :950-958
[2]  
Albanell E, 2003, J AOAC INT, V86, P746
[3]  
American Public Health Association, 1993, STANDARD METHODS EXA
[4]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[5]   Effect of cleaning procedure and hygienic condition of milking equipment on bacterial count of bulk tank milk [J].
Bava, Luciana ;
Zucali, Maddalena ;
Sandrucci, Anna ;
Brasca, Milena ;
Vanoni, Laura ;
Zanini, Lucio ;
Tamburini, Alberto .
JOURNAL OF DAIRY RESEARCH, 2011, 78 (02) :211-219
[6]   Prediction of moisture, fat and inorganic salts in processed cheese by near infrared reflectance spectroscopy and multivariate data analysis [J].
Blazquez, C ;
Downey, G ;
O'Donnell, C ;
O'Callaghan, D ;
Howard, V .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2004, 12 (03) :149-157
[7]   Development of a flow cytometric method to analyze subpopulations of bacteria in probiotic products and dairy starters [J].
Bunthof, CJ ;
Abee, T .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2002, 68 (06) :2934-2942
[8]   Comparison of near and medium infrared spectroscopy to predict fatty acid composition on fresh and thawed milk [J].
Coppa, Mauro ;
Revello-Chion, Andrea ;
Giaccone, Daniele ;
Ferlay, Anne ;
Tabacco, Ernesto ;
Borreani, Giorgio .
FOOD CHEMISTRY, 2014, 150 :49-57
[9]  
De Reu K, 2004, J FOOD SAFETY, V24, P17
[10]  
Dhuol K. R. R., 2014, INT J CURRENT RES AC, V2, P1