摘要
Currently MRI is extensively used for the evaluation of cardiovascular and thoracic disorders because of the well-established advantages that include use of non-ionizing radiation, good contrast and high spatial resolution. Despite the advantages of this technique, numerous categories of artefacts are frequently encountered. They may be related to the scanner hardware or software functionalities, environmental factors or the human body itself. In particular, some artefacts may be exacerbated with high-field-strength MR machines (e.g. 3T). Cardiac imaging poses specific challenges with respect to breath-holding and cardiac motion. In addition, new cardiac MR-conditional devices may also be responsible for peculiar artefacts. The image quality may thus be impaired and give rise to a misdiagnosis. Knowledge of acquisition and reconstruction techniques is required to understand and recognize the nature of these artefacts. This article will focus on the origin and appearance of the most common artefacts encountered in cardiac and chest MRI along with possible correcting methods to avoid or reduce them.
引用
收藏
页数:8
相关论文
共 10 条
[1]   European cardiovascular magnetic resonance (EuroCMR) registry - multi national results from 57 centers in 15 countries [J].
Bruder, Oliver ;
Wagner, Anja ;
Lombardi, Massimo ;
Schwitter, Juerg ;
van Rossum, Albert ;
Pilz, Guenter ;
Nothnagel, Detlev ;
Steen, Henning ;
Petersen, Steffen ;
Nagel, Eike ;
Prasad, Sanjay ;
Schumm, Julia ;
Greulich, Simon ;
Cagnolo, Alessandro ;
Monney, Pierre ;
Deluigi, Christina C. ;
Dill, Thorsten ;
Frank, Herbert ;
Sabin, Georg ;
Schneider, Steffen ;
Mahrholdt, Heiko .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
[2]   Chemical Shift Encoding-Based Water-Fat Separation Methods [J].
Eggers, Holger ;
Boernert, Peter .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (02) :251-268
[3]  
Erasmus L., 2004, S AFR J RADIOL, V8, P13, DOI 10.4102/sajr.v8i2.127
[4]   Cardiovascular magnetic resonance artefacts [J].
Ferreira, Pedro F. ;
Gatehouse, Peter D. ;
Mohiaddin, Raad H. ;
Firmin, David N. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
[5]   Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteria [J].
Klinke, Vincenzo ;
Muzzarelli, Stefano ;
Lauriers, Nathalie ;
Locca, Didier ;
Vincenti, Gabriella ;
Monney, Pierre ;
Lu, Christian ;
Nothnagel, Detlev ;
Pilz, Guenter ;
Lombardi, Massimo ;
van Rossum, Albert C. ;
Wagner, Anja ;
Bruder, Oliver ;
Mahrholdt, Heiko ;
Schwitter, Juerg .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
[6]  
Schiebler M L, 1992, Top Magn Reson Imaging, V4, P1
[7]  
Schwitter J, 2012, CMR UPDATE
[8]   Impact of the Advisa MRI pacing system on the diagnostic quality of cardiac MR images and contraction patterns of cardiac muscle during scans: Advisa MRI randomized clinical multicenter study results [J].
Schwitter, Juerg ;
Kanal, Emanuel ;
Schmitt, Matthias ;
Anselme, Frederic ;
Albert, Timothy ;
Hayes, David L. ;
Bello, David ;
Toth, Attila ;
Chang, Yanping ;
van Osch, Dirk ;
Sommer, Torsten .
HEART RHYTHM, 2013, 10 (06) :864-872
[9]   Artifacts in body MR imaging: their appearance and how to eliminate them [J].
Stadler, Alfred ;
Schima, Wolfgang ;
Ba-Ssalamah, Ahmed ;
Kettenbach, Joachim ;
Eisenhuber, Edith .
EUROPEAN RADIOLOGY, 2007, 17 (05) :1242-1255
[10]   Compressed Sensing Single-Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass [J].
Vincenti, Gabriella ;
Monney, Pierre ;
Chaptinel, Jerome ;
Rutz, Tobias ;
Coppo, Simone ;
Zenge, Michael O. ;
Schmidt, Michaela ;
Nadar, Mariappan S. ;
Piccini, Davide ;
Chevre, Pascal ;
Stuber, Matthias ;
Schwitter, Juerg .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (09) :882-892