Validation of a finite element model of the human metacarpal

被引:32
作者
Barker, DS
Netherway, DJ
Krishnan, J
Hearn, TC
机构
[1] Flinders Univ S Australia, Adelaide, SA 5001, Australia
[2] Univ Adelaide, Adelaide, SA, Australia
基金
英国医学研究理事会; 澳大利亚研究理事会;
关键词
finite element; human; metacarpal; validation; strain gauge; in vitro; anisotropic;
D O I
10.1016/j.medengphy.2004.10.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Implant loosening and mechanical failure of components are frequently reported following metacarpophalangeal (MCP) joint replacement. Studies of the mechanical environment of the MCP implant-bone construct are rare. The objective of this study was to evaluate the predictive ability of a finite element model of the intact second human metacarpal to provide a validated baseline for further mechanical studies. A right index human metacarpal was subjected to torsion and combined axial/bending loading using strain gauge (SG) and 3D finite element (FE) analysis. Four different representations of bone material properties were considered. Regression analyses were performed comparing maximum and minimum principal surface strains taken from the SG and FE models. Regression slopes close to unity and high correlation coefficients were found when the diaphyseal cortical shell was modelled as anisotropic and cancellous bone properties were derived from quantitative computed tomography. The inclusion of anisotropy for cortical bone was strongly influential in producing high model validity whereas variation in methods of assigning stiffness to cancellous bone had only a minor influence. The validated FE model provides a tool for future investigations of current and novel MCP joint prostheses. (C) 2004 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 43 条
[1]  
AHNFELT L, 1990, ACTA ORTHOP SCAND, V61, P1
[2]  
Akay M, 1996, J BIOMED MATER RES, V31, P167
[3]   FORCES IN THE NORMAL AND ABNORMAL HAND [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (02) :202-211
[4]   The skeletal response to matt and polished cemented femoral stems [J].
Barker, DS ;
Wang, AW ;
Yeo, MF ;
Nawana, NS ;
Brumby, SA ;
Pearcy, MJ ;
Howie, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1182-1188
[5]   METACARPOPHALANGEAL JOINT PROSTHESES - A REVIEW OF THE CLINICAL-RESULTS OF PAST AND CURRENT DESIGNS [J].
BEEVERS, DJ ;
SEEDHOM, BB .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1995, 20B (02) :125-136
[6]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[7]  
CARTER DR, 1978, CLIN ORTHOP RELAT R, V135, P192
[8]   EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY [J].
CIARELLI, MJ ;
GOLDSTEIN, SA ;
KUHN, JL ;
CODY, DD ;
BROWN, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :674-682
[9]  
Cordey J, 1999, INJURY, V30, pS7
[10]   MECHANICAL AND TEXTURAL PROPERTIES OF PELVIC TRABECULAR BONE [J].
DALSTRA, M ;
HUISKES, R ;
ODGAARD, A ;
VANERNING, L .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :523-535