A novel adaptive wrist actigraphy algorithm for sleep-wake assessment in sleep apnea patients

被引:149
作者
Hedner, J
Pillar, G
Pittman, SD
Zou, D
Grote, L
White, DP
机构
[1] Sahlgrenska Univ Hosp, Sleep Lab, Gothenburg, Sweden
[2] Technion Israel Inst Technol, Rambam Med Ctr, Sleep Lab, Haifa, Israel
[3] Brigham & Womens Hosp, Sleep Div, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Boston, MA 02115 USA
关键词
actigraph; polysomnograph; Watch_PAT 100; sleep/wake;
D O I
10.1093/sleep/27.8.1560
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Current actigraphic algorithms are relatively less accurate in detecting sleep and wake in sleep apnea patients than in people without sleep apnea. In the current study, we attempted to validate a novel automatic algorithm, which was developed for actigraphic studies in normal subjects and patients with obstructive sleep apnea by comparing it on an epoch-by-epoch basis to standard polysomnography. Design: Prospective cohort study. Setting: Multicenter, university hospital, sleep laboratories. Participants: A total of 228 subjects from 3 different sleep centers (Skara, Boston, Haifa) participated. Intervention and Measurements: Simultaneous recording of polysomnography and Watch_PAT100, an ambulatory device that contains a built-in actigraph. The automatic sleep/wake algorithm is based on both the quantification of motion (magnitude and duration) and the various periodic movement patterns, such as those occurring in patients with moderate to severe obstructive sleep apnea. Results: The overall sensitivity and specificity to identify sleep was 89% and 69%, respectively. The agreement ranged from 86% in the normal subjects to 86%, 84%, and 80% in the patients with mild, moderate, and severe obstructive sleep apnea, respectively. There was a tight agreement between actigraphy and polysomnography in determining sleep efficiency (78.4 +/- 9.9 vs 78.8 +/- 13.4%), total sleep time (690 +/- 152 vs 690 +/- 154 epochs), and sleep latency (56.8 +/- 31.4 vs 43.3 +/- 45.4 epochs). While for most individuals the difference between the polysomnography and actigraphy was relatively small, for some there was a substantial disagreement. Conclusions: We conclude that this actigraphy algorithm provides a reasonably accurate estimation of sleep and wakefulness in normal subjects and patients with obstructive sleep apnea on an epoch-by-epoch basis. This simple method for assessment of total sleep time may provide a useful tool for the accurate quantification of obstructive sleep apnea in the home environment.
引用
收藏
页码:1560 / 1566
页数:7
相关论文
共 42 条
[1]   The role of actigraphy in the study of sleep and circadian rhythms [J].
Ancoli-Israel, S ;
Cole, R ;
Alessi, C ;
Chambers, M ;
Moorcroft, W ;
Pollak, CP .
SLEEP, 2003, 26 (03) :342-392
[2]   Use of wrist activity for monitoring sleep/wake in demented nursing-home patients [J].
AncoliIsrael, S ;
Clopton, P ;
Klauber, MR ;
Fell, R ;
Mason, W .
SLEEP, 1997, 20 (01) :24-27
[3]   AMBULATORY EVALUATION OF SLEEP DISTURBANCE AND THERAPEUTIC EFFECTS IN SLEEP-APNEA SYNDROME BY WRIST ACTIVITY MONITORING [J].
AUBERTTULKENS, G ;
CULEE, C ;
HARMANTVANRIJCKEVORSEL, K ;
RODENSTEIN, DO .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (04) :851-856
[4]   Heart rate variability in patients with sleep-related breathing disorders [J].
Bauer, T ;
Ewig, S ;
Schafer, H ;
Jelen, E ;
Omran, H ;
Luderitz, B .
CARDIOLOGY, 1996, 87 (06) :492-496
[5]  
Blood ML, 1997, SLEEP, V20, P388
[6]   Home assessment of sleep disorders by portable monitoring [J].
Broughton, R ;
Fleming, J ;
Fleetham, J .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1996, 13 (04) :272-284
[7]  
COLE M, 1992, CHILDRENS DEV SOCIAL, V1, P5
[8]   AMBULATORY MONITORING OF ARTERIAL OXYGEN-SATURATION [J].
DECKER, MJ ;
HOEKJE, PL ;
STROHL, KP .
CHEST, 1989, 95 (04) :717-722
[9]  
DVIR I, 2002, J SLEEP RES, V11, P109
[10]  
Elbaz M, 2002, SLEEP, V25, P527