Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions

被引:31
作者
Garcia-Lazaro, Santiago [1 ]
Ferrer-Blasco, Teresa [1 ]
Madrid-Costa, David [1 ]
Albarran-Diego, Cesar [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, Optometry Res Grp GIO, E-46100 Burjassot, Valencia, Spain
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2015年 / 41卷 / 01期
关键词
Simultaneous-image multifocal contact lens; Visual performance; Glare; CONTRAST SENSITIVITY; PUPIL; CATARACT; SURGERY; LIGHT; LIFE;
D O I
10.1097/ICL.0000000000000060
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare. Methods: In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; Bausch & Lomb], Acuvue Oasys for Presbyopia [AOP; Johnson & Johnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wearing, each subject's binocular distance visual acuity (BDVA) and binocular distance contrast sensitivity (BDCS) were measured using the Functional Visual Analyzer (Stereo Optical Co., Inc.) under mesopic conditions (3 candela [cd]/m(2)) both with no glare and under the 2 levels of induced glare: 1.0 lux (glare 1) and 28 lux (glare 2). Results: Among the SIMCLs, in terms of BDVA, AOAM and PM outperformed BM and AOP. All contact lenses performed better at level without glare, followed by Glare 1, and with the worst results obtained under glare 2. Binocular distance contrast sensitivity revealed statistically significant differences for 12 cycles per degree (cpd). Among the SIMCLs, post hoc multiple comparison testing revealed that AOAM and PM provided the best BDCS at the three luminance levels. In both cases, BDVA and BDCS at 12 cpd, monofocal contact lenses outperformed all SIMCL ones at all lighting conditions. Conclusions: Air Optix Aqua Multifocal and PM provided better visual performance than BM and AOP for distance vision with low addition and under dim conditions, but they all provide worse performance than monofocal contact lenses.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 34 条
[1]  
Benjamin W J, 1991, J Am Optom Assoc, V62, P743
[2]  
BORISH IM, 1988, AM J OPTOM PHYS OPT, V65, P417
[3]  
Borish IM., 2006, CLIN REFRACTION, P99
[4]   EFFECTS OF TARGET DISTANCE AND PUPIL SIZE ON LETTER CONTRAST SENSITIVITY WITH SIMULTANEOUS VISION BIFOCAL CONTACT-LENSES [J].
BRADLEY, A ;
RAHMAN, HA ;
SONI, PS ;
ZHANG, XX .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (06) :476-481
[5]  
Chamberlain P, 2011, OPTOMETRY VISION SCI, V8, P334
[6]   Infrared pupillometry in presbyopes fitted with soft contact lenses [J].
Chateau, N ;
DeBrabander, J ;
Bouchard, F ;
Molenaar, H .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (12) :733-741
[7]  
Erickson P, 1988, J Am Optom Assoc, V59, P198
[8]  
ERICKSON P, 1985, AM J OPTOM PHYS OPT, V62, P702
[9]   Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses [J].
Garcia-Lazaro, Santiago ;
Albarran-Diego, Cesar ;
Ferrer-Blasco, Teresa ;
Radhakrishnan, Hema ;
Montes-Mico, Robert .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (01) :46-52
[10]  
Haegerstrom-Portnoy G, 1999, INVEST OPHTH VIS SCI, V38, P207