A DESCRIPTIVE STUDY OF THE RADIOGRAPHIC DENSITY OF IMPLANT RESTORATIVE CEMENTS

被引:63
作者
Wadhwani, Chandur [1 ]
Hess, Timothy
Faber, Thomas [2 ]
Pineyro, Alfonso [1 ]
Chen, Curtis S. K. [3 ]
机构
[1] Dept Restorat Dent, Bellevue, WA 98004 USA
[2] Univ Washington, Dept Periodontol, Seattle, WA 98195 USA
[3] Univ Washington, Div Radiol, Dept Oral Med, Seattle, WA 98195 USA
关键词
LUTING AGENTS; RADIODENSITY; RETENTION;
D O I
10.1016/S0022-3913(10)60062-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Cementation of implant prostheses is a common practice. Excess cement in the gingival sulcus may harm the periodontal tissues. Identification of the excess cement may be possible with the use of radiographs if the cement has sufficient radiopacity. Purpose. The purpose of this study was to compare the radiographic density of different cements used for implant prostheses. Material and methods. Eight different cements were compared: TempBond Original (TBO), TempBond NE (TBN), Fleck's (FL), Dycal (DY), RelyX Unicem (RXU), RelyX Luting (RXL), Improv (IM), and Premier Implant Cement (PIC). Specimen disks, 2 mm in thickness, were radiographed. Images were made using photostimulable phosphor (PSP) plates with standardized exposure values. The average grey level of the central area of each specimen disk was selected and measured in pixels using a software analysis program, ImageTool, providing an average grey level value representative of radiodensity for each of the 8 cements. The radiodensity was determined using the grey level values of the test materials, which were recorded and compared to a standard aluminum step wedge. An equivalent thickness of aluminum in millimeters was calculated using best straight line fit estimates. To assess contrast effects by varying the exposure settings, a second experiment using 1-mm-thick cement specimens radiographed at both 60 kVp and 70 kVp was conducted. The PSP plates with specimens were measured for a grey level value comparison to the standard aluminum step wedge, using the same software program. Results. The highest grey level values were recorded for the zinc cements (TBO, TBN, and FL), with the 1-mm specimen detectable at both 60- and 70-kVp settings. A lower grey level was recorded for DY, indicative of a lower radiodensity compared to the zinc cements, but higher than RXL and RXU. The implant-specific cements had the lowest grey level values. IM could only be detected in 2-mm-thick sections with a lower aluminum equivalence value than the previously mentioned cements. PIC could not be detected radiographically for either the 1-mm or 2-mm thicknesses at either of the kVp settings. Conclusions. Some types of cement commonly used for the cementation of implant-supported prostheses have poor radiodensity and may not be detectable following radiographic examination. (J Prosthet Dent 2010;103:295-302)
引用
收藏
页码:295 / 302
页数:8
相关论文
共 27 条
  • [1] Cement removal from restorations luted to titanium abutments with simulated subgingival margins
    Agar, JR
    Cameron, SM
    Hughbanks, JC
    Parker, MH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (01) : 43 - 47
  • [2] *AM DENT ASS, 2004, ADA FDA GUID PAT SEL
  • [3] Detection of small differences in mass using a direct digital dental X-ray system
    Chen, SK
    Hollender, L
    Omnell, KA
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1997, 26 (01) : 63 - 66
  • [4] De Rouck T, 2008, INT J ORAL MAX IMPL, V23, P897
  • [5] Devito Karina Lopes, 2004, J. Appl. Oral Sci., V12, P290, DOI 10.1590/S1678-77572004000400007
  • [6] Techniques to minimize excess luting agent in cement-retained implant restorations
    Dumbrigue, HB
    Abanomi, AA
    Cheng, LL
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (01) : 112 - 114
  • [7] Radiodensity of base, liner and luting dental materials
    Fonseca, Rodrigo Borges
    Branco, Carolina Assaf
    Soares, Paulo Vinicius
    Correr-Sobrinho, Louren O.
    Haiter-Neto, Francisco
    Fernandes-Neto, Alfredo Julio
    Soares, Carlos Jose
    [J]. CLINICAL ORAL INVESTIGATIONS, 2006, 10 (02) : 114 - 118
  • [8] Physical properties of resinous cements:: an in vitro study
    Fraga, RC
    Luca-Fraga, LRL
    Pimenta, LAF
    [J]. JOURNAL OF ORAL REHABILITATION, 2000, 27 (12) : 1064 - 1067
  • [9] Gapski R, 2008, INT J ORAL MAX IMPL, V23, P943
  • [10] Radiopacity of dental materials using a digital X-ray system
    Gu, Steven
    Rasimick, Brian J.
    Deutsch, Allan S.
    Musikant, Barry Lee
    [J]. DENTAL MATERIALS, 2006, 22 (08) : 765 - 770