Newly Developed Novel Ultrasound Technique, Defect Reperfusion Ultrasound Imaging, Using Sonazoid in the Management of Hepatocellular Carcinoma

被引:84
作者
Kudo, Masatoshi [1 ]
Hatanaka, Kinuyo [1 ]
Maekawa, Kiyoshi [2 ]
机构
[1] Kinki Univ, Sch Med, Dept Gastroenterol & Hepatol, Osaka 5898511, Japan
[2] Kinki Univ, Sch Med, Div Ultrasound, Osaka 5898511, Japan
关键词
Ultrasound; contrast-enhanced harmonic; Sonazoid; Hepatic tumors; Radiofrequency ablation; Guidance; treatment-assisted; Defect reperfusion imaging; Kupffer phase imaging; PERCUTANEOUS RADIOFREQUENCY ABLATION; INVERSION HARMONIC SONOGRAPHY; B-MODE SONOGRAPHY; DIFFERENTIAL-DIAGNOSIS; HEPATIC-TUMORS; PHASE; US; THERAPY; LESIONS; LIVER;
D O I
10.1159/000315229
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study is to clarify the usefulness of defect reperfusion ultrasound (US) imaging using Sonazoid in the management of hepatocellular carcinoma (HCC). A total of 33 HCC nodules and 34 local recurring nodules after radio-frequency ablation (RFA), which could not be identified by B-mode US but were depicted by dynamic CT, were studied by defect reperfusion US imaging with Sonazoid. In addition, Kupffer phase Sonazoid-enhanced US in combination with defect reperfusion US imaging were used for screening HCC in 262 consecutive cirrhotic patients. As a result, 33 US undetectable HCC nodules and 34 local recurring HCC nodules were successfully confirmed by Sonazoid-enhanced US with defect reperfusion imaging. Subsequently, RFA was successfully performed in all of 67 HCC nodules with a Sonazoid-enhanced US guidance. A total of 7 small HCCs were depicted and confirmed as HCCs by Kupffer phase surveillance and defect reperfusion US imaging. In conclusion, defect reperfusion US imaging is extremely useful in the depiction and confirmation of US undetectable HCCs as well as in the surveillance of HCC in cirrhotic patients. Copyright (C) 2010 S. Karger AG, Basel
引用
收藏
页码:40 / 45
页数:6
相关论文
共 15 条
[1]   Hepatocellular carcinoma: Depiction of tumor parenchymal flow with intermittent harmonic power Doppler US during the early arterial phase in dual-display model [J].
Ding, H ;
Kudo, M ;
Onda, H ;
Suetomi, Y ;
Minami, Y ;
Maekawa, K .
RADIOLOGY, 2001, 220 (02) :349-356
[2]   Evaluation of posttreatment response of hepatocellular carcinoma with contrast-enhanced coded phase-inversion harmonic US: Comparison with dynamic CT [J].
Ding, H ;
Kudo, M ;
Onda, H ;
Suetomi, Y ;
Minami, Y ;
Chung, H ;
Kawasaki, T ;
Maekawa, K .
RADIOLOGY, 2001, 221 (03) :721-730
[3]   Contrast-enhanced subtraction harmonic sonography for evaluating treatment response in patients with hepatocellular carcinoma [J].
Ding, H ;
Kudo, M ;
Onda, H ;
Suetomi, Y ;
Minami, Y ;
Maekawa, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (03) :661-666
[4]   Differential diagnosis of hepatic tumors: Value of contrast-enhanced harmonic Sonography using the newly developed contrast agent, Sonazoid [J].
Hatanaka, Kinuyo ;
Kudo, Masatoshi ;
Minami, Yasunori ;
Ueda, Taisuke ;
Tatsumi, Chie ;
Kitai, Satoshi ;
Takahashi, Shunsuke ;
Inoue, Tatsuo ;
Hagiwara, Satoru ;
Chung, Hobyung ;
Ueshima, Kazuomi ;
Maekawa, Kiyoshi .
INTERVIROLOGY, 2008, 51 :61-69
[5]  
Hatanaka Kinuyo, 2008, Oncology, V75 Suppl 1, P42, DOI 10.1159/000173423
[6]   Differential diagnosis of nodular lesions in cirrhotic liver by post-vascular phase contrast-enhanced US with Levovist: comparison with superparamagnetic iron oxide magnetic resonance images [J].
Inoue, T ;
Kudo, M ;
Watai, R ;
Pei, Z ;
Kawasaki, T ;
Minami, Y ;
Chung, H ;
Fukunaga, T ;
Awai, K ;
Maenishi, O .
JOURNAL OF GASTROENTEROLOGY, 2005, 40 (12) :1139-1147
[7]   Local ablation therapy for hepatocellular carcinoma: current status and future perspectives [J].
Kudo, M .
JOURNAL OF GASTROENTEROLOGY, 2004, 39 (03) :205-214
[8]  
Kudo M, 2007, KANZO, V48, P299
[9]  
KUDO M, 2003, CONTRAST HARMONIC IM, P1
[10]   Treatment of hepatocellular carcinoma with percutaneous radiofrequency ablation: Usefulness of contrast harmonic sonography for lesions poorly defined with B-mode sonography [J].
Minami, Y ;
Kudo, M ;
Kawasaki, T ;
Chung, H ;
Ogawa, C ;
Shiozaki, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (01) :153-156