EVALUATION OF AUTOMATIC ATLAS-BASED LYMPH NODE SEGMENTATION FOR HEAD-AND-NECK CANCER

被引:119
作者
Stapleford, Liza J. [2 ]
Lawson, Joshua D. [2 ]
Perkins, Charles [2 ]
Edelman, Scott [2 ]
Davis, Lawrence [2 ]
McDonald, Mark W. [2 ,3 ]
Waller, Anthony [2 ]
Schreibmann, Eduard [2 ]
Fox, Tim [1 ,2 ]
机构
[1] Emory Univ, Sch Med, Winship Canc Ctr, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[3] Indiana Univ, Dept Radiat Oncol, Melvin & Bren Simon Canc Ctr, Indianapolis, IN 46204 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 77卷 / 03期
关键词
Auto-segmentation; Intensity-modulated radiotherapy; Deformable image registration; Interobserver variability; Neck nodal volumes; DEFORMABLE IMAGE REGISTRATION; MODULATED RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; VOLUME DELINEATION; TARGET; CT; VARIABILITY; DEFINITION; CARCINOMA; IMPACT;
D O I
10.1016/j.ijrobp.2009.09.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate if automatic atlas-based lymph node segmentation (INS) improves efficiency and decreases inter-observer variability while maintaining accuracy. Methods and Materials: Five physicians with head-and-neck IMRT experience used computed tomography (CT) data from 5 patients to create bilateral neck clinical target volumes covering specified nodal levels. A second contour set was automatically generated using a commercially available atlas. Physicians modified the automatic contours to make them acceptable for treatment planning. To assess contour variability, the Simultaneous Truth and Performance Level Estimation (STAPLE) algorithm was used to take collections of contours and calculate a probabilistic estimate of the "true" segmentation. Differences between the manual, automatic, and automatic-modified (AM) contours were analyzed using multiple metrics. Results: Compared with the "true" segmentation created from manual contours, the automatic contours had a high degree of accuracy, with sensitivity, Dice similarity coefficient, and mean/max surface disagreement values comparable to the average manual contour (86%, 76%, 3.3/17.4 nun automatic vs. 73%, 79%, 2.8/17 mm manual). The AM group was more consistent than the manual group for multiple metrics, most notably reducing the range of contour volume (106-430 mL manual vs. 176-347 mL AM) and percent false positivity (1-37% manual vs. 1-7% AM). Average contouring time savings with the automatic segmentation was 11.5 min per patient, a 35% reduction. Conclusions: Using the STAPLE algorithm to generate "true" contours from multiple physician contours, we demonstrated that, in comparison with manual segmentation, atlas-based automatic LNS for head-and-neck cancer is accurate, efficient, and reduces interobserver variability. (C) 2010 Elsevier Inc.
引用
收藏
页码:959 / 966
页数:8
相关论文
共 18 条
[1]   Reduce in variation and improve efficiency of target volume delineation by a computer-assisted system using a deformable image registration approach [J].
Chao, K. S. Clifford ;
Bhide, Shreerang ;
Chen, Hansen ;
Asper, Joshua ;
Bush, Steven ;
Franklin, Gregg ;
Kavadi, Vivek ;
Liengswangwong, Vichaivood ;
Gordon, William ;
Raben, Adam ;
Strasser, Jon ;
Koprowski, Christopher ;
Frank, Steven ;
Chronowski, Gregory ;
Ahamad, Anesa ;
Malyapa, Robert ;
Zhang, Lifei ;
Dong, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (05) :1512-1521
[2]   Intensity-modulated radiation therapy reduces late salivary toxicity without compromising tumor control in patients with oropharyngeal carcinoma: a comparisons with conventional techniques [J].
Chao, KSC ;
Majhail, N ;
Huang, CJ ;
Simpson, JR ;
Perez, CA ;
Haughey, B ;
Spector, G .
RADIOTHERAPY AND ONCOLOGY, 2001, 61 (03) :275-280
[3]   Determination and delineation of nodal target volumes for head-and-neck cancer based on patterns of failure in patients receiving definitive and postoperative IMRT [J].
Chao, KSC ;
Wippold, FJ ;
Ozyigit, G ;
Tran, BN ;
Dempsey, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1174-1184
[4]   An evaluation of the variability of tumor-shape definition derived by experienced observers from CT images of supraglottic carcinomas (ACRIN protocol 6658) [J].
Cooper, Jay S. ;
Mukherji, Suresh K. ;
Toledano, Alicia Y. ;
Beldon, Clifford ;
Schmalfuss, Ilona M. ;
Amdur, Robert ;
Sailer, Scott ;
Loevner, Laurie A. ;
Kousouboris, Phil ;
Ang, K. Kian ;
Cormack, Jean ;
Sicks, JoRean .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :972-975
[5]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[6]   Intensity-modulated radiation therapy for head and neck cancer: Emphasis on the selection and delineation of the targets [J].
Eisbruch, A ;
Foote, RL ;
O'Sullivan, B ;
Beitler, JJ ;
Vikram, B .
SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) :238-249
[7]   Quality of life and survival outcome for patients with nasopharyngeal carcinoma receiving three-dimensional conformal radiotherapy vs. intensity-modulated radiotherapy - A longitudinal study [J].
Fang, Fu-Min ;
Chien, Chih-Yen ;
Tsai, Wen-Ling ;
Chen, Hui-Chun ;
Hsu, Hsuan-Chih ;
Lui, Chun-Chung ;
Huang, Tai-Lin ;
Huang, Hsuan-Ying .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (02) :356-364
[8]   Future issues in highly conformal radiotherapy for head and neck cancer [J].
Feng, Mary ;
Eisbruch, Avraham .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (08) :1009-1013
[9]   CT-based delineation of lymph node levels and related CTVs in the node-negative neck:: DAHANCA, EORTC, GORTEC, NCIC, RTOG consensus guidelines [J].
Grégoire, V ;
Levendag, P ;
Ang, KK ;
Bernier, J ;
Braaksma, M ;
Budach, V ;
Chao, C ;
Coche, E ;
Cooper, JS ;
Cosnard, G ;
Eisbruch, A ;
El-Sayed, S ;
Emami, B ;
Grau, C ;
Hamoir, M ;
Lee, N ;
Maingon, P ;
Muller, K ;
Reychler, H .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :227-236
[10]   Laryngeal tumor volume measurements determined with CT: A study on intra- and interobserver variability [J].
Hermans, R ;
Feron, M ;
Bellon, E ;
Dupont, P ;
Van den Bogaert, W ;
Baert, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (03) :553-557