Automated polyp measurement with CT colonography: Preliminary observations in a phantom colon model

被引:14
作者
Fletcher, Joel G.
Booya, Fargol
Melton, Zachary
Johnson, Kristina
Guendel, Lutz
Schmidt, Bernhard
McCollough, Cynthia H.
Young, Brett
Fidler, Jeff L.
Harmsen, William S.
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Siemens Med Solut, Malvern, PA USA
关键词
colon cancer; CT colonography; polyps;
D O I
10.2214/AJR.06.1169
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the accuracy and precision of polyp measurements obtained with an automated tool in a colon phantom containing polyps of multiple sizes, morphologic types, and locations. MATERIALS AND METHODS. A colon phantom was scanned at 12, 25, 50, and 100 mA with standard CT colonographic acquisition parameters. Four reviewers using manual 2D methods and an automated polyp measurement tool measured 24 polyps of varying sizes and morphologic types, some at a haustral fold tip and some not at a fold tip. The accuracy (difference from true value) of manual and automated methods was compared across polyp sizes, morphologic types, locations, and doses. Precision (closeness of different measures) was compared for intraobserver and interobserver measurements. RESULTS. The accuracy of automated polyp measurement was dependent on morphologic type (p <= 0.02), size (for three of four reviewers, p <= 0.05), and location of polyps with respect to haustral folds (two of four reviewers, p <= 0.01). For two of four reviewers, automated measures were less accurate for 5-mm polyps, flat polyps, and polyps at the tips of folds (p <= 0.04). Intraobserver precision was high, two automated measurements being within 0.1 mm of each other 82-93% of the time. Interobserver precision values for automated measures were more similar 85% of the time (82/96; p < 0.001). CONCLUSION. Accuracy of automated polyp measurements depends on polyp size, morphologic type, and location. When using an automated tool, radiologists should visually inspect automated polyp measurements, particularly for small and flat polyps and those located on folds, because manual measurements may be more accurate in this setting. Automated polyp measurements are more precise than manual measurements.
引用
收藏
页码:945 / 952
页数:8
相关论文
共 16 条
[11]   Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults [J].
Pickhardt, PJ ;
Choi, JR ;
Hwang, I ;
Butler, JA ;
Puckett, ML ;
Hildebrandt, HA ;
Wong, RK ;
Nugent, PA ;
Mysliwiec, PA ;
Schindler, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (23) :2191-2200
[12]  
Rockey DC, 2005, LANCET, V365, P305
[13]   Adenoma characteristics at first colonoscopy as predictors of adenoma recurrence and characteristics at follow-up [J].
van Stolk, RU ;
Beck, GJ ;
Baron, JA ;
Haile, R ;
Summers, R .
GASTROENTEROLOGY, 1998, 115 (01) :13-18
[14]   Comparison of supine and prone scanning separately and in combination at CT colonography [J].
Yee, J ;
Kumar, NN ;
Hung, RK ;
Akerkar, GA ;
Kumar, PRG ;
Wall, SD .
RADIOLOGY, 2003, 226 (03) :653-661
[15]   Polyp measurement with CT colonography: Multiple-reader, multiple-workstation comparison [J].
Young, Brett M. ;
Fletcher, J. G. ;
Paulsen, Scott R. ;
Booya, Fargol ;
Johnson, C. Daniel ;
Johnson, Kristina T. ;
Melton, Zackary ;
Rodysill, Drew ;
Mandrekar, Jay .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :122-129
[16]   CT colonography reporting and data system: A consensus proposal [J].
Zalis, ME ;
Barish, MA ;
Choi, JR ;
Dachman, AH ;
Fenlon, HM ;
Ferrucci, JT ;
Glick, SN ;
Laghi, A ;
Macari, M ;
McFarland, EG ;
Morrin, MM ;
Pickhardt, PJ ;
Soto, J ;
Yee, J .
RADIOLOGY, 2005, 236 (01) :3-9