Water disinfection using silver nanoparticle impregnated activated carbon: Escherichia coli cell-killing in batch and continuous packed column operation over a long duration

被引:67
作者
Biswas, Pritam [1 ]
Bandyopadhyaya, Rajdip [1 ]
机构
[1] Indian Inst Technol, Dept Chem Engn, Bombay 400076, Maharashtra, India
关键词
Water disinfection; Silver nanoparticle; Activated carbon; Escherichia coli; Packed column; Drinking water; GENERATION; BEADS;
D O I
10.1016/j.watres.2016.04.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Silver nanoparticles (Ag-NP) were selectively impregnated on the external surface of plasma treated activated carbon (AC) granules (referred to as Ag-AC hybrid, having 0.8 wt% of Ag), for achieving continuous disinfection of water in a single flow-column set-up. First, Ag-NPs (28 nm mean size) were synthesized by UV reduction. Subsequently, Escherichia coli cell-killing experiments were performed in both shake flask (i.e. batch-mode) and flow-column (i.e. continuous-mode) operations, using E. coli K12 (MTCC 1302) as a model organism. Batch results using 8 mg Ag-AC hybrid/ml of cell suspension showed that, 10(4) CFU/ml of cells were killed within 25 min contact time, with cell concentration decaying exponentially in time. Maintaining almost the same contact time as in the batch experiments, three columns packed with Ag-AC (all having a height of 25 cm but increasing diameters of 1, 5 and 8 cm, respectively) were used for monitoring cell-killing performance over a long duration. For all columns, inlet water having 10(4) CFU/ml E. coli could be completely disinfected to produce treated, outlet water having zero cell count. Specifically for the 8 cm diameter column, a maximum throughput of treating 1.62 L of contaminated water per hour could be maintained for at least up to 16 days. Moreover, the Ag concentration in the outlet water was only up to 29.8 mu g/L at steady state, which is well within the recommended limit of 100 mu g/L for drinking water. Hence, water disinfection for potable quality water (zero E. coli count and <100 mu g/L Ag) can be achieved in a continuous manner over a long duration, with our packed Ag-AC column. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:105 / 115
页数:11
相关论文
共 26 条
[1]  
Acevedo S., 2014, J NANOMEDICINE RES, V1
[2]   Silver-embedded granular activated carbon as an antibacterial medium for water purification [J].
Bandyopadhyaya, Rajdip ;
Sivaiah, M. Venkata ;
Shankar, P. A. .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2008, 83 (08) :1177-1180
[3]  
Brennan J. K., 2010, COLLOID SURF A, V187-188, P539
[4]   The effects of UV disinfection on drinking water quality in distribution systems [J].
Choi, Yonkyu ;
Choi, Young-june .
WATER RESEARCH, 2010, 44 (01) :115-122
[5]   UV/H2O2 treatment of drinking water increases post-chlorination DBP formation [J].
Dotson, Aaron D. ;
Keen, Volha S. ;
Metz, Debbie ;
Linden, Karl G. .
WATER RESEARCH, 2010, 44 (12) :3703-3713
[6]   BIOFOULING ON MEMBRANES - A MICROBIOLOGICAL APPROACH [J].
FLEMMING, HC ;
SCHAULE, G .
DESALINATION, 1988, 70 (1-3) :95-119
[7]   Polymeric microspheres containing silver nanoparticles as a bactericidal agent for water disinfection [J].
Gangadharan, D. ;
Harshvardan, Kumar ;
Gnanasekar, G. ;
Dixit, Dhara ;
Popat, Kiritkumar Mangaldas ;
Anand, Pritpal Singh .
WATER RESEARCH, 2010, 44 (18) :5481-5487
[8]   Potential of silver nanoparticle-coated polyurethane foam as an antibacterial water filter [J].
Jain, P ;
Pradeep, T .
BIOTECHNOLOGY AND BIOENGINEERING, 2005, 90 (01) :59-63
[9]  
Krantzberg G., 2010, ADV WATER QUALITY CO, P41
[10]   IDENTIFICATION OF A CENTRAL REGULATOR OF STATIONARY-PHASE GENE-EXPRESSION IN ESCHERICHIA-COLI [J].
LANGE, R ;
HENGGEARONIS, R .
MOLECULAR MICROBIOLOGY, 1991, 5 (01) :49-59