IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults

被引:153
作者
Welchko, BA
Jahns, TM
Soong, WL
Nagashima, JA
机构
[1] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
[2] Univ Adelaide, Dept Elect & Elect Engn, Adelaide, SA 5005, Australia
[3] GM Corp, Ctr Adv Technol, Torrance, CA 90503 USA
关键词
interior permanent magnet synchronous machine; inverter shutdown; protection; short circuit fault; variable speed drive;
D O I
10.1109/TEC.2003.811746
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A closed-form solution is presented for the steady-state response of interior permanent magnet (IPM) synchronous machines to symmetrical short circuits including the effects of q-axis magnetic saturation. Machine response to single-phase asymmetrical short circuits is also investigated. Experimental data are presented to verify predicted behavior for both types of short circuits. It is shown that single-phase asymmetrical short circuit faults produce more severe fault responses with high pulsating torque and a significant threat of rotor demagnetization. A control strategy that purposely transitions such faults into symmetrical three-phase short circuits can minimize the fault severity and associated demagnetization risks. Implications for the design of IPM machines with improved fault tolerance are discussed.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 13 条
[1]  
ADNANES AK, 1991, PESC 91 RECORD, P695, DOI 10.1109/PESC.1991.162751
[2]  
BIANCHI N, 1996, P C REC POW EL SPEC, V2, P1542
[3]  
HWANG HH, 1969, IEEE T POWER AP SYST, VPA88, P67, DOI 10.1109/TPAS.1969.292339
[4]   A comparative study of permanent magnet and switched reluctance motors for high-performance fault-tolerant applications [J].
Jack, AG ;
Mecrow, BC ;
Haylock, JA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (04) :889-895
[5]   INTERIOR PERMANENT-MAGNET SYNCHRONOUS MOTORS FOR ADJUSTABLE-SPEED DRIVES [J].
JAHNS, TM ;
KLIMAN, GB ;
NEUMANN, TW .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1986, 22 (04) :738-747
[6]   Uncontrolled generator operation of interior PM synchronous machines following high-speed inverter shutdown [J].
Jahns, TM ;
Caliskan, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (06) :1347-1357
[7]  
Lovelace E., 2000, THESIS MIT CAMBRIDGE
[8]  
REDDY G, 1971, P I ELECTR ENG, V118, P161
[9]  
Soong W. L, 1993, THESIS U GLASGOW GLA
[10]   FIELD-WEAKENING PERFORMANCE OF BRUSHLESS SYNCHRONOUS AC MOTOR-DRIVES [J].
SOONG, WL ;
MILLER, TJE .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1994, 141 (06) :331-340