IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults

被引:149
作者
Welchko, BA
Jahns, TM
Soong, WL
Nagashima, JA
机构
[1] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
[2] Univ Adelaide, Dept Elect & Elect Engn, Adelaide, SA 5005, Australia
[3] GM Corp, Ctr Adv Technol, Torrance, CA 90503 USA
关键词
interior permanent magnet synchronous machine; inverter shutdown; protection; short circuit fault; variable speed drive;
D O I
10.1109/TEC.2003.811746
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A closed-form solution is presented for the steady-state response of interior permanent magnet (IPM) synchronous machines to symmetrical short circuits including the effects of q-axis magnetic saturation. Machine response to single-phase asymmetrical short circuits is also investigated. Experimental data are presented to verify predicted behavior for both types of short circuits. It is shown that single-phase asymmetrical short circuit faults produce more severe fault responses with high pulsating torque and a significant threat of rotor demagnetization. A control strategy that purposely transitions such faults into symmetrical three-phase short circuits can minimize the fault severity and associated demagnetization risks. Implications for the design of IPM machines with improved fault tolerance are discussed.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 13 条