Phase-resolved spectral-domain magnetomotive optical coherence tomography

被引:4
作者
Crecea, Vasilica [1 ,2 ]
Oldenburg, Amy L. [1 ,3 ]
Ralston, Tyler S. [1 ,3 ]
Boppart, Stephen A. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Biophoton Imaging Lab, Chicago, IL 60680 USA
[2] Univ Illinois, Dept Phys, Chicago, IL 60680 USA
[3] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL 60680 USA
[4] Univ Illinois, Dept Bioengn, Chicago, IL 60680 USA
[5] Univ Illinois, Dept Med, Chicago, IL 60680 USA
来源
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI | 2007年 / 6429卷
关键词
optical coherence tomography; phase detection; sensitivity; contrast agents; magnetic nanoparticles;
D O I
10.1117/12.702649
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We advance the magnetomotive-optical coherence tomography (MM-OCT) technique for detecting displacements of magnetic nanoparticles embedded in tissue-like phantoms by using apmplitude and phase-resolved methods with spectral-domain optical coherence tomography (SD-OCT). The magnetomotion is triggered by the external, noninvasive application of a magnetic field. We show that both amplitude and phase data are indicative of the presence and motion of light scatterers, and could potentially be used for studying the dynamics of magnetomotion. The magnetic field modulation is synchronized with data acquisition in a controlled, integrated system that includes a console for monitoring and initiating data acquisition, scanning devices, an electromagnet power supply, and the detection system. Using Fourier analysis, we show that the amplitude and phase modulations in the samples that contain magnetic contrast agents match the frequency of the applied magnetic field, while control samples do not respond to magnetic field activity. We vary the, strength of the magnetic field and show that the amplitude and phase steps between regions of zero-magnetic field and regions with non-zero magnetic field change accordingly. The phase is shown to be more sensitive.
引用
收藏
页数:10
相关论文
共 29 条
[1]   Optical probes and techniques for molecular contrast enhancement in coherence imaging [J].
Boppart, SA ;
Oldenburg, AL ;
Xu, CY ;
Marks, DL .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[2]   Spectral-domain phase microscopy [J].
Choma, MA ;
Ellerbee, AK ;
Yang, CH ;
Creazzo, TL ;
Izatt, JA .
OPTICS LETTERS, 2005, 30 (10) :1162-1164
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Doppler flow imaging of cytoplasmic streaming using spectral domain phase microscopy [J].
Choma, Michael A. ;
Ellerbee, Audrey K. ;
Yazdanfar, Siavash ;
Izatt, Joseph A. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
[5]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[6]   Double-shot depth-resolved displacement field measurement using phase-contrast spectral optical coherence tomography [J].
De la Torre-Ibarra, Manuel H. ;
Ruiz, Pablo D. ;
Huntley, Jonathan M. .
OPTICS EXPRESS, 2006, 14 (21) :9643-9656
[7]   Real-time phase-resolved optical coherence tomography and optical Doppler tomography [J].
Ding, ZH ;
Zhao, YH ;
Ren, HW ;
Nelson, JS ;
Chen, ZP .
OPTICS EXPRESS, 2002, 10 (05) :236-245
[8]  
FANGYEN C, 2004, OPT LETT, V29, P17
[9]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI 10.2184/lsj.31.635
[10]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181