POTENTIAL RISK FACTORS OF ATRIAL FIBRILLATION RECURRENCE AFTER CRYOBALLOON ABLATION

被引:0
|
作者
Novikov, I. A. [1 ]
Novikov, P. S. [1 ]
Mironov, N. U. [1 ]
Yu, Laiovich L. [1 ]
Malkina, T. A. [1 ]
Shariya, M. A. [1 ]
Sokolov, S. F. [1 ]
Maikov, E. B. [1 ]
机构
[1] Natl Med Res Ctr Cardiol, Moscow, Russia
关键词
Atrial fibrillation; cryoballoon ablation; risk factors; early recurrence; common pulmonary venous collector; antiarrhythmic drugs; PULMONARY VEIN ISOLATION; CATHETER ABLATION; PHARMACOLOGICAL CARDIOVERSION; PREDICTORS; CONSENSUS; OUTCOMES; SOCIETY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim To identify risk factors for recurrence of atrial fibrillation (AF) following cryoballoon ablation (CBA). Material and methods This prospective study included patients with paroxysmal AF who had undergone CBA (141 patients, median age 60 years, 3% men). The evaluation prior to CBA included clinical instrumental parameters (electrocardiography (ECG), 24-h ECG monitoring, echocardiography, contrast-enhanced cardiac multispiral computed tomography). Also, possible intraoperative indexes that could affect the CBA effectivity, were evaluated. The postoperative follow-up duration was 12 months. Effectivity was assessed during in-person visits at 3, 6, and 12 months, when questioning of patients and 24-h ECG monitoring were performed. CBA was considered ineffective if the patient had recurrences of any atrial tachyarrhythmia longer than 30 sec after the end of the 3-month "blind" period. Results During the 12-month follow-up, recurrences of atrial tachyarrhythmia were observed in 46 (32.6%) patients. Patients with ineffective CBA more frequently had AF during the first 3 months (71.7% vs. 11.6%; p<0.001). Such patients had a history of multiple ineffective treatments with antiarrhythmic drugs (AAD), common pulmonary venous (PV) collector (41.3 % vs. 20.0%; p=0.008), and stroke/recurrent ischemic attacks (15.2 % vs. 5.2%; p=0.047). Multifactorial regression analysis showed that the factors of AF recurrence included common PV collector (relative risk (RR) 2.35; 95 % confidence interval (CI) 1.29-4.25; p=0.005), multiple ineffective AADs (RR 1.42; 95% CI 1.08-1.86; p=0.011), and early AF recurrence (RR 7.57; 95% CI 3.84-14.90; p<0.001). Conclusion Common PV collector and multiple ineffective AADs are risk factors of ineffective CBA. Early recurrences during the first 3 postoperative months are a significant risk factor of long-term AF recurrences.
引用
收藏
页码:23 / 29
页数:7
相关论文
共 50 条
  • [11] Association of left atrial wall thickness with recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Yixuan Bai
    Ruikun Jia
    Xinmeng Wang
    Juan Chan
    Kaijun Cui
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 657 - 667
  • [12] Incremental value of left atrial strain to predict atrial fibrillation recurrence after cryoballoon ablation
    Motoc, Andreea
    Luchian, Maria-Luiza
    Scheirlynck, Esther
    Roosens, Bram
    Chameleva, Hadischat
    Galloo, Xavier
    von Kemp, Berlinde
    Ramak, Robbert
    Sieira, Juan
    de Amundis, Carlo
    Chierchia, Gian-Battista
    Magne, Julien
    Weytjens, Caroline
    Droogmans, Steven
    Cosyns, Bernard
    ACTA CARDIOLOGICA, 2023, 78 : 28 - 28
  • [13] Association of left atrial wall thickness with recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Bai, Yixuan
    Jia, Ruikun
    Wang, Xinmeng
    Chan, Juan
    Cui, Kaijun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (03) : 657 - 667
  • [14] Linear lesions for treating the recurrence of persistent atrial tachyarrhythmia after cryoballoon ablation of atrial fibrillation
    Hermida, Alexis
    Diouf, Momar
    Faya, Floriane
    Kubalaa, Maciej
    Burtina, Jacqueline
    Lallemand, Pierre-Marc
    Buiciuc, Otilia
    Zaitouni, Mustafa
    Lieu, Audrey
    Hermida, Jean-Sylvain
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2022, 115 (05) : 252 - 263
  • [15] Incremental value of left atrial strain to predict atrial fibrillation recurrence after cryoballoon ablation
    Motoc, A.
    Luchian, M. L.
    Scheirlynck, E.
    Roosens, B.
    Chameleva, H.
    Galloo, X.
    Von Kemp, B.
    Ramak, R.
    Sieira, J.
    De Asmundis, C.
    Chierchia, G. B.
    Magne, J.
    Weytjens, C.
    Droogmans, S.
    Cosyns, B.
    EUROPEAN HEART JOURNAL, 2022, 43 : 9 - 9
  • [16] Association of typical atrial flutter and cavotricuspid isthmus ablation on clinical recurrence after cryoballoon ablation for atrial fibrillation
    Jeong, Joo Hee
    Lee, Hyoung Seok
    Choi, Yun Young
    Kim, Yun Gi
    Choi, Jong-Il
    Kim, Young-Hoon
    Lim, Hong Euy
    Oh, Il-Young
    Cha, Myung-Jin
    Lee, So-Ryoung
    Kim, Ju Youn
    Kwon, Chang Hee
    Lee, Sung Ho
    Park, Junbeom
    Kim, Ki-Hun
    Yang, Pil-Sung
    Kim, Jun-Hyung
    Shim, Jaemin
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [17] Association of Typical Atrial Flutter and Cavotricuspid Isthmus Ablation on Clinical Recurrence after Cryoballoon Ablation for Atrial Fibrillation
    Jeong, Joo Hee
    Cha, Myung-Jin
    Kim, Ju Youn
    Kim, Jun-Hyung
    Kim, Ki-Hun
    Kwon, Chang Hee
    Lee, So-Ryoung
    Lee, Sung Ho
    Lim, Hong Euy
    Oh, Il-Young
    Park, Junbeom
    Yang, Pil-Sung
    Lee, Hyoung Seok
    Choi, Yun Young
    Kim, Yun Gi
    Choi, Jong-il
    Kim, Young Hoon
    Park, Yae Min
    Shim, Jaemin
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1276 - 1276
  • [18] Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?
    Marcus Wieczorek
    Kiarash Sassani
    Reinhard Hoeltgen
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 321 - 327
  • [19] Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?
    Wieczorek, Marcus
    Sassani, Kiarash
    Hoeltgen, Reinhard
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (02) : 321 - 327
  • [20] Risk factors of recurrence of paroxysmal atrial fibrillation after radiofrequency catheter ablation
    Zhang, X. L.
    Fu, H.
    Wei, X.
    Liang, Y. J.
    Tang, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 731 - 731