Preparation and application of cryptand-coated piezoelectric crystal gas-chromatographic detector

被引:14
作者
Chang, P [1 ]
Shih, JS [1 ]
机构
[1] Natl Taiwan Normal Univ, Dept Chem, Taipei 11718, Taiwan
关键词
piezoelectric crystal; gas-chromatographic detector; cryptand; organic vapour sensor;
D O I
10.1016/S0003-2670(97)00691-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A re-usable and sensitive cryptand-22-coated quartz-crystal membrane piezoelectric sensor with a homemade computer interface for signal acquisition and data processing was prepared and applied as a gas-chromatographic (GC) detector for various organic molecules. The oscillating frequency of the quartz crystal decreased due to the adsorption of organic molecules on cryptand-22. Effects of functional group, molar mass, steric hindrance and polarity of organic molecules on frequency responses of the cryptand-coated piezoelectric crystal detector were investigated. The cryptand-coated piezoelectric crystal GC detector had demonstrated high sensitivity for various polar organic molecules and good reproducibility when reused. The frequency responses of the cryptand-coated crystal for various molecules were in the following order: carboxylic acids (RCOOH)>>primary amines (R-NH2)>alcohols (ROH)>secondary amines (R2NH)>tertiary amines (R3N)>ketones. More polar molecules exhibited better frequency responses. The effect of temperature and amount of coating on the frequency responses of cryptand-coated crystal GC detector were also investigated. The cryptand-coated piezoelectric crystal GC detector compared well with the commercial thermal conductivity detector (TCD). (C) 1998 Elsevier Science B.V.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 25 条
[1]   PIEZOELECTRIC-CRYSTALS FOR MASS AND CHEMICAL MEASUREMENTS - A REVIEW [J].
ALDER, JF ;
MCCALLUM, JJ .
ANALYST, 1983, 108 (1291) :1169-1189
[2]  
[Anonymous], 1989, SENSORS COMPREHENSIV
[3]   SELECTION OF ADSORBATES FOR CHEMICAL SENSOR ARRAYS BY PATTERN-RECOGNITION [J].
CAREY, WP ;
BEEBE, KR ;
KOWALSKI, BR ;
ILLMAN, DL ;
HIRSCHFELD, T .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :149-153
[4]   THE APPLICATION OF CRYPTAND 22 AS A BIFUNCTIONAL STATIONARY PHASE FOR ION CHROMATOGRAPHY [J].
CHEN, SJ ;
SHIH, JS .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1991, 38 (03) :211-216
[5]  
Cram D.J., 1978, J CHROMATOGR, V167, P307
[6]  
CURIE P, 1880, B SOC MINER FR, V3, P90
[7]   CONTINUOUS LIQUID-PHASE PIEZOELECTRIC BIOSENSOR FOR KINETIC IMMUNOASSAYS [J].
DAVIS, KA ;
LEARY, TR .
ANALYTICAL CHEMISTRY, 1989, 61 (11) :1227-1230
[8]  
DIETRICH B, 1969, TETRAHEDRON LETT, V34, P2885
[9]  
EMOSALAMY MAF, 1989, ANAL P, V26, P12
[10]  
Guilbault G. G., 1984, APPL PIEZOELECTRIC Q