Noise in restaurants: Levels and mathematical model

被引:11
作者
To, Wai Ming [1 ]
Chung, Andy W. L. [2 ]
机构
[1] Macao Polytech Inst, Sch Business, Taipa, Peoples R China
[2] EDMS Hong Kong Ltd, Dept Environm Sci, Hong Kong, Hong Kong, Peoples R China
关键词
Indoor noise levels; occupational exposure; restaurants; SOUND PRESSURE LEVELS; INDOOR AIR-QUALITY; SMOKE; EXPOSURE; COOKING; WORKERS; CITIES; SAFETY; HEALTH; MUSIC;
D O I
10.4103/1463-1741.144412
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Noise affects the dining atmosphere and is an occupational hazard to restaurant service employees worldwide. This paper examines the levels of noise in dining areas during peak hours in different types of restaurants in Hong Kong SAR, China. A mathematical model that describes the noise level in a restaurant is presented. The 1-h equivalent continuous noise level (L-eq,L-1-h) was measured using a Type-1 precision integral sound level meter while the occupancy density, the floor area of the dining area, and the ceiling height of each of the surveyed restaurants were recorded. It was found that the measured noise levels using L-eq,L-1-h ranged from 67.6 to 79.3 dBA in Chinese restaurants, from 69.1 to 79.1 dBA in fast food restaurants, and from 66.7 to 82.6 dBA in Western restaurants. Results of the analysis of variance show that there were no significant differences between means of the measured noise levels among different types of restaurants. A stepwise multiple regression analysis was employed to determine the relationships between geometrical and operational parameters and the measured noise levels. Results of the regression analysis show that the measured noise levels depended on the levels of occupancy density only. By reconciling the measured noise levels and the mathematical model, it was found that people in restaurants increased their voice levels when the occupancy density increased. Nevertheless, the maximum measured hourly noise level indicated that the noise exposure experienced by restaurant service employees was below the regulated daily noise exposure value level of 85 dBA.
引用
收藏
页码:368 / 373
页数:6
相关论文
共 41 条
[1]   An international survey of indoor air quality, ventilation, and smoking activity in restaurants:: a pilot study [J].
Bohanan, HR ;
Piadé, JJ ;
Schorp, MK ;
Saint-Jalm, Y .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2003, 13 (05) :378-392
[2]  
Bulter G, 2010, THE OREGONIAN 0625
[3]   An inter-comparison of VOC types and distribution in different indoor environments in a university campus [J].
Chan, Daniel W. T. ;
Tam, Cinnie S. Y. ;
Jones, A. P. .
INDOOR AND BUILT ENVIRONMENT, 2007, 16 (04) :376-382
[4]   Carcinogenic potential, levels and sources of polycyclic aromatic hydrocarbon mixtures in indoor and outdoor environments and their implications for air quality standards [J].
Delgado-Saborit, Juana Maria ;
Stark, Christopher ;
Harrison, Roy M. .
ENVIRONMENT INTERNATIONAL, 2011, 37 (02) :383-392
[5]  
Finz S, 2008, SAN FRANCISCO C 0604
[6]   Promoting Health and Safety in San Francisco's Chinatown Restaurants: Findings and Lessons Learned from a Pilot Observational Checklist [J].
Gaydos, Megan ;
Bhatia, Rajiv ;
Morales, Alvaro ;
Lee, Pam Tau ;
Liu, Shaw San ;
Chang, Charlotte ;
Salvatore, Alicia L. ;
Krause, Niklas ;
Minkler, Meredith .
PUBLIC HEALTH REPORTS, 2011, 126 :62-69
[7]  
Hong Kong Census and Statistics Department, 2011, KEY STAT BUS PERF OP
[8]  
Hong Kong Food and Environmental Hygiene Department, 2012, GUID APPL REST LIC
[9]  
Ising H, 2004, Noise Health, V6, P5
[10]   Dangerous Dining Health and Safety in the New York City Restaurant Industry [J].
Jayaraman, Saru ;
Dropkin, Jonathan ;
Siby, Sekou ;
Alston, Laine Romero ;
Markowitz, Steven .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2011, 53 (12) :1418-1424