Bioabsorbable anterior cervical plating - Initial multicenter clinical and radiographic experience

被引:25
作者
Aryan, Henry E.
Lu, Daniel C.
Acosta, Frank L., Jr.
Hartl, Roger
McCormick, Patrick W.
Ames, Christopher P.
机构
[1] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
[2] Cornell Univ, Dept Neurol Surg, Ithaca, NY 14853 USA
[3] Neurosurg Network Inc, Toledo, OH USA
关键词
anterior cervical discectomy; bioabsorbable; cervical; fusion; plate; polymer;
D O I
10.1097/01.brs.0000261489.66229.c1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Prospective clinical trial. Objective. The authors present their initial multicenter experience in the surgical management of 1-level degenerative disc disease of the cervical spine with anterior cervical discectomy and fusions (ACDF) using a bioabsorbable polymer plate. Summary of Background Data. The introduction of a radiolucent bioabsorbable polymer plate and screws for ACDF presents a novel opportunity to gain the some of the potential added benefit of stabilization with internal immobilization while possibly reducing some of the long-term complications and imaging artifacts associated with titanium instrumentation. We prospectively analyze 52 patients who were treated at 6 different institutions across the United States with bioabsorbable polymer plate and screws for ACDF surgery. Methods. Patients were prospectively enrolled. A retrospective review of patients' charts and imaging was performed to determine clinical and radiographic outcome following anterior cervical spine surgery. Specifically, the authors looked at need for additional surgeries, local reaction to bioabsorbable polymer, fusion rate, and complications. Surgeries involved the C4-C5, C5-C6, C6-C7, and/or C7-T1 levels. Cadaveric bone was used in 42 patients, polyetheretherketone ( PEEK) cages in 6 patients, and iliac crest autograft in 4 patients. The patients were observed for an average of 13.3 months. Results. Radiographic fusion was achieved in 98.1% ( 51 of 52 patients) of the cases at 6 months. One patient has evidence of nonunion on flexion-extension imaging but remains asymptomatic. A different patient developed mild kyphosis after surgery and had persistence of radicular symptoms but refused further surgery. There were no clinical signs or symptoms of reaction to the bioabsorbable material. Conclusions. The rates of fusion following single-level ACDF with internal fixation using bioabsorbable polymer plate and screws in this study match those previously reported in the literature with metallic implants and are superior to noninstrumented fusions. Preliminary results suggest that this newly available technology for anterior fusion may be as effective as traditional titanium plating systems in single-level disease. The bioabsorbable material appears to be well tolerated by patients. A larger, randomized, controlled study is necessary to bring the results to statistical significance.
引用
收藏
页码:1084 / 1088
页数:5
相关论文
共 21 条
[1]   Feasibility of a resorbable anterior cervical graft containment plate [J].
Ames, CP ;
Cornwall, GB ;
Crawford, NR ;
Nottmeier, E ;
Chamberlain, RH ;
Sonntag, VKH .
JOURNAL OF NEUROSURGERY, 2002, 97 (04) :440-446
[2]  
Anderson DG, 2002, ORTHOP CLIN N AM, V33, P317
[3]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[4]   LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[5]  
Ciccone W J 2nd, 2001, J Am Acad Orthop Surg, V9, P280
[6]   New bioresorbable pin for the reduction of small bony fragments: Design, mechanical properties and in vitro degradation [J].
Claes, LE ;
Ignatius, AA ;
Rehm, KE ;
Scholz, C .
BIOMATERIALS, 1996, 17 (16) :1621-1626
[7]  
Connolly PJ, 1996, J SPINAL DISORD, V9, P202
[8]   Resorbable plate fixation in pediatric craniofacial surgery [J].
Eppley, BL ;
Sadove, AM ;
Havlik, RJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (01) :1-7
[9]   Biomechanical evaluation of titanium, biodegradable plate and screw, and cyanoacrylate glue fixation systems in craniofacial surgery [J].
Gosain, AK ;
Song, LS ;
Corrao, MA ;
Pintar, FA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (03) :582-591
[10]   Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft [J].
Kaiser, MG ;
Haid, RW ;
Subach, BR ;
Barnes, B ;
Rodts, GE .
NEUROSURGERY, 2002, 50 (02) :229-236