Does metal transfer differ on retrieved Biolox® Delta composites femoral heads? Surface investigation on three Biolox® generations from a biotribological point of view

被引:22
作者
Affatato, Saverio [1 ]
Ruggiero, Alessandro [2 ]
Merola, Massimiliano [2 ]
Logozzo, Silvia [3 ]
机构
[1] Rizzoli Orthopaed Inst, Med Technol Lab, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Univ Salerno, Dept Ind Engn, Salerno, Italy
[3] V GER Srl, Dept Res & Dev, Via Mori 6, Bologna, Italy
关键词
Biotribology; Biolox (R) Delta; Metal transfer; Digital surface analysis; Roughness; IN-VITRO; TRIBOLOGICAL BEHAVIOR; ROUGHNESS MEASUREMENT; PHASE-TRANSFORMATION; ACETABULAR CUP; CERAMIC HIP; STRIPE WEAR; ALUMINA; JOINT; MICROSEPARATION;
D O I
10.1016/j.compositesb.2017.01.026
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background: Currently, little is known about the effects that metal transfer affecting hip implants may have on roughness. The main aim of this study is to propose a metrological technique in order to better characterize this phenomenon on the surface of composite ceramic femoral heads, discussing its influence on the biotribological behaviour of the coupling. In addition, through the acquired data, we investigate whether the metal transfer extension and roughness alterations on a femoral head is correlated to the material, the follow-up of the implant and whether metal transfer is associated with changes in the roughness of alumina surface, considering different follow-ups. Methods: Three generations of femoral heads manufactured in ceramic (Biolox (R), Biolox (R) Forte, and Biolox (R) Delta) were retrieved from patients after different implantation periods (mean follow up = 6.9 years) and they were analysed using a roughness tester and an optical non-contact 3D scanner, in order to characterize the metal transfer on the bearing surface. Results: Surface area where the metal transfer was observed ranged between 29.6 mm(2) and 573.6 mm(2). The mean values of Sa (average roughness) were different between the Affected Zone (0.3 +/- 0.1 mu m) and Unaffected Zone (0.03 +/- 0.1 mu m). In particular, regions of metal transfer were rougher than the non-metal transfer regions of the articular surface and this is demonstrated by both the areal roughness parameters considered: Sa (arithmetic mean height) and St (maximum height of the surface) parameters (p = 0.002, Wilcoxon paired-test). St parameter acquired on the Biolox (R) Delta femoral heads showed the lowest mean value (11.92 mu m). Conclusion: We found no correlation between follow-up vs. roughness and total surface area of metal transfer. Furthermore, we found that the amount of areal coverage of metal transfer is correlated with the surface roughness. Finally, MT effect on composite ceramic implants caused lower height of peaks and valleys when compared to common ceramic. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:164 / 173
页数:10
相关论文
共 53 条
[1]   Effect of sintering temperature on properties of Al2O3 whisker reinforced 3 mol% Y2O3 stabilized tetragonal ZrO2 (TZ-3Y) nanocomposites [J].
Abdullah, Muhammad ;
Ahmad, Jamil ;
Mehmood, Mazhar .
COMPOSITES PART B-ENGINEERING, 2012, 43 (04) :1785-1790
[2]  
Abu-amer Y, 2007, ASEPTIC LOOSENING TO, V7, P1
[3]   The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints [J].
Affatato, S ;
Bersaglia, G ;
Yin, JQ ;
Traina, F ;
Toni, A ;
Viceconti, M .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H3) :457-464
[4]   Retrieval analysis of three generations of Biolox® femoral heads: Spectroscopic and SEM characterisation [J].
Affatato, S. ;
Modena, E. ;
Toni, A. ;
Taddei, P. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 13 :118-128
[5]   Alumina-on-alumina hip implants A WEAR STUDY OF RETRIEVED COMPONENTS [J].
Affatato, S. ;
Traina, F. ;
De Fine, M. ;
Carmignato, S. ;
Toni, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (01) :37-42
[6]   Mixed oxides prosthetic ceramic ball heads.: Part 3:: effect of the ZrO2 fraction on the wear of ceramic on ceramic hip joint prostheses.: A long-term in vitro wear study [J].
Affatato, S ;
Goldoni, M ;
Testoni, M ;
Toni, A .
BIOMATERIALS, 2001, 22 (07) :717-723
[7]   Does metal transfer affect the tribological behaviour of femoral heads? Roughness and phase transformation analyses on retrieved zirconia and Biolox® Delta composites [J].
Affatato, Saverio ;
Ruggiero, Alessandro ;
De Mattia, Jonathan Salvatore ;
Taddei, Paola .
COMPOSITES PART B-ENGINEERING, 2016, 92 :290-298
[8]   Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings [J].
Affatato, Saverio ;
Ruggiero, Alessandro ;
Merola, Massimiliano .
COMPOSITES PART B-ENGINEERING, 2015, 83 :276-283
[9]   In vitro wear performance of standard, crosslinked, and vitamin-E-blended UHMWPE [J].
Affatato, Saverio ;
Bracco, Pierangiola ;
Costa, Luigi ;
Villa, Tomaso ;
Quaglini, Virginio ;
Toni, Aldo .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (03) :554-560
[10]   Wear of metal-on-metal hip bearings: metallurgical considerations after hip simulator studies [J].
Affatato, Saverio ;
Traina, Francesco ;
Ruggeri, Oddone ;
Toni, Aldo .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (12) :1155-1164