Micropulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma

被引:168
作者
Tan, Anna M. [1 ]
Chockalingam, Muthuraman [2 ]
Aquino, Maria C. [1 ]
Lim, Zena I-L [3 ]
See, Jovina L-S [1 ]
Chew, Paul T. K. [1 ]
机构
[1] Natl Univ Singapore Hosp, Dept Ophthalmol, Singapore 119074, Singapore
[2] Uma Eye Clin, Madras, Tamil Nadu, India
[3] Singapore Natl Eye Ctr, Singapore, Singapore
关键词
micropulse laser; refractory glaucoma; transscleral diode cyclophotocoagulation; trans-pars plana; DIABETIC MACULAR EDEMA; INTRAOCULAR-PRESSURE; RETINAL PHOTOCOAGULATION; CYCLOCRYOTHERAPY; SECONDARY; EYES;
D O I
10.1111/j.1442-9071.2010.02238.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Transscleral diode laser cyclophotocoagulation (TSCPC) is an established method of treatment for refractory glaucoma, but is associated with significant complications. This study evaluates the efficacy and safety of a new form of TSCPC using micropulse diode laser and trans-pars plana treatment with a novel contact probe. Methods: Prospective interventional case series of 40 eyes of 38 consecutive patients with refractory glaucoma treated with micropulse TSCPC with a novel probe. Outcomes measured were success, hypotony and response rates. Results: The mean age of patients was 63.2 +/- 16.0 years. The mean follow-up period was 16.3 +/- 4.5 months. The mean intraocular pressure (IOP) before micropulse TSCPC was 39.3 +/- 12.6 mmHg. Mean IOP decreased to 31.1 +/- 13.4 mmHg at 1 day, 28.0 +/- 12.0 mmHg at 1 week, 27.4 +/- 12.7 mmHg at 1 month, 27.1 +/- 13.6 mmHg at 3 months, 25.8 +/- 14.5 mmHg at 6 months, 26.6 +/- 14.7 mmHg at 12 months and 26.2 +/- 14.3 mmHg at 18 months (P < 0.001 at all time points). No patient had hypotony or loss of best-corrected visual acuity. The overall success rate after a mean of 1.3 treatment sessions was 72.7%. Conclusion: Micropulse TSCPC is a safe and effective method of lowering IOP in cases of refractory glaucoma and is comparable with conventional TSCPC.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 32 条
[21]   Primary surgical management refractory glaucoma: tubes as initial surgery [J].
Nguyen, Quang H. .
CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (02) :122-125
[22]   Diode laser contact transscleral cyclophotocoagulation: Getting the most from the G-probe [J].
Noecker, R ;
Kelly, T ;
Patterson, E ;
Herrygers, LA .
OPHTHALMIC SURGERY LASERS & IMAGING, 2004, 35 (02) :124-130
[23]   Outcomes of trabeculectomy for primary open-angle glaucoma [J].
NouriMahdavi, K ;
Brigatti, L ;
Weitzman, M ;
Caprioli, J .
OPHTHALMOLOGY, 1995, 102 (12) :1760-1769
[24]   Comparison of acute structural and histopathological changes of the porcine ciliary processes after endoscopic cyclophotocoagulation and transscleral cyclophotocoagulation [J].
Pantcheva, Mina B. ;
Kahook, Malik Y. ;
Schuman, Joel S. ;
Rubin, Marc W. ;
Noecker, Robert J. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (03) :270-274
[25]   Subthreshold grid laser treatment of macular edema secondary to branch retinal vein occlusion with micropulse infrared (810 nanometer) diode laser [J].
Parodi, Maurizio Battaglia ;
Spasse, Sonela ;
Iacono, Pierluigi ;
Di Stefano, Giuseppe ;
Canziani, Tiziana ;
Ravalico, Giuseppe .
OPHTHALMOLOGY, 2006, 113 (12) :2237-2242
[26]   Tissue effects of subclinical diode laser treatment of the retina [J].
Pollack, JS ;
Kim, JE ;
Pulido, JS ;
Burke, JM .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (12) :1633-1639
[27]   The number of people with glaucoma worldwide in 2010 and 2020 [J].
Quigley, HA ;
Broman, AT .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (03) :262-267
[28]   Transscleral diode laser cyclophotocoagulation for the treatment of refractory glaucoma secondary to inflammatory eye diseases [J].
Schlote, T ;
Derse, M ;
Zierhut, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (09) :999-1003
[29]  
SCHUBERT HD, 1990, OPHTHALMIC SURG LAS, V21, P835
[30]   Subthreshold micropulse diode laser photocoagulation for clinically significant diabetic macular oedema: a three-year follow up [J].
Sivaprasad, Sobha ;
Sandhu, Ranjit ;
Tandon, Anamika ;
Sayed-Ahmed, Khalid ;
McHugh, Dominic A. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (07) :640-644