Micropulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma

被引:168
作者
Tan, Anna M. [1 ]
Chockalingam, Muthuraman [2 ]
Aquino, Maria C. [1 ]
Lim, Zena I-L [3 ]
See, Jovina L-S [1 ]
Chew, Paul T. K. [1 ]
机构
[1] Natl Univ Singapore Hosp, Dept Ophthalmol, Singapore 119074, Singapore
[2] Uma Eye Clin, Madras, Tamil Nadu, India
[3] Singapore Natl Eye Ctr, Singapore, Singapore
关键词
micropulse laser; refractory glaucoma; transscleral diode cyclophotocoagulation; trans-pars plana; DIABETIC MACULAR EDEMA; INTRAOCULAR-PRESSURE; RETINAL PHOTOCOAGULATION; CYCLOCRYOTHERAPY; SECONDARY; EYES;
D O I
10.1111/j.1442-9071.2010.02238.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Transscleral diode laser cyclophotocoagulation (TSCPC) is an established method of treatment for refractory glaucoma, but is associated with significant complications. This study evaluates the efficacy and safety of a new form of TSCPC using micropulse diode laser and trans-pars plana treatment with a novel contact probe. Methods: Prospective interventional case series of 40 eyes of 38 consecutive patients with refractory glaucoma treated with micropulse TSCPC with a novel probe. Outcomes measured were success, hypotony and response rates. Results: The mean age of patients was 63.2 +/- 16.0 years. The mean follow-up period was 16.3 +/- 4.5 months. The mean intraocular pressure (IOP) before micropulse TSCPC was 39.3 +/- 12.6 mmHg. Mean IOP decreased to 31.1 +/- 13.4 mmHg at 1 day, 28.0 +/- 12.0 mmHg at 1 week, 27.4 +/- 12.7 mmHg at 1 month, 27.1 +/- 13.6 mmHg at 3 months, 25.8 +/- 14.5 mmHg at 6 months, 26.6 +/- 14.7 mmHg at 12 months and 26.2 +/- 14.3 mmHg at 18 months (P < 0.001 at all time points). No patient had hypotony or loss of best-corrected visual acuity. The overall success rate after a mean of 1.3 treatment sessions was 72.7%. Conclusion: Micropulse TSCPC is a safe and effective method of lowering IOP in cases of refractory glaucoma and is comparable with conventional TSCPC.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 32 条
  • [1] CYCLOCRYOTHERAPY - A REVIEW OF CASES OVER A 10-YEAR PERIOD
    BENSON, MT
    NELSON, ME
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1990, 74 (02) : 103 - 105
  • [2] Berger JW, 1997, LASER SURG MED, V20, P409, DOI 10.1002/(SICI)1096-9101(1997)20:4<409::AID-LSM6>3.0.CO
  • [3] 2-U
  • [4] ''Cyclodiode'' - Trans-scleral diode laser cyclophotocoagulation in the treatment of advanced refractory glaucoma
    Bloom, PA
    Tsai, JC
    Sharma, K
    Miller, MH
    Rice, NSC
    Hitchings, RA
    Khaw, PT
    [J]. OPHTHALMOLOGY, 1997, 104 (09) : 1508 - 1519
  • [5] CAPRIOLI J, 1985, OPHTHALMOLOGY, V92, P947
  • [6] CHONG LP, 1992, INVEST OPHTH VIS SCI, V33, P722
  • [7] Micropulse and continuous wave diode retinal photocoagulation: visible and subvisible lesion parameters
    Desmettre, T. J.
    Mordon, S. R.
    Buzawa, D. M.
    Mainster, M. A.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (06) : 709 - 712
  • [8] FELDMANN RM, 1997, J GLAUCOMA, V2, P139
  • [9] ALTERATION OF PULSE CONFIGURATION AFFECTS THE PAIN RESPONSE DURING DIODE-LASER PHOTOCOAGULATION
    FRIBERG, TR
    VENKATESH, S
    [J]. LASERS IN SURGERY AND MEDICINE, 1995, 16 (04) : 380 - 383
  • [10] Gupta N, 1997, J GLAUCOMA, V6, P426