Direct in Vivo Electrochemical Detection of Resting Dopamine Using Poly(3,4-ethylenedioxythiophene)/Carbon Nanotube Functionalized Microelectrodes

被引:73
作者
Taylor, Ian Mitchell [1 ,2 ]
Patel, Nikita Anurag [1 ]
Freedman, Noah Chaim [1 ]
Castagnola, Elisa [1 ]
Cui, Xinyan Tracy [1 ]
机构
[1] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15261 USA
[2] St Vincent Coll, Dept Chem, Latrobe, PA 15650 USA
关键词
INCREASE EXTRACELLULAR DOPAMINE; RAT NUCLEUS-ACCUMBENS; QUANTITATIVE MICRODIALYSIS; INVIVO VOLTAMMETRY; MICE LACKING; STRIATUM; RELEASE; TRANSMISSION; AMPHETAMINE; COCAINE;
D O I
10.1021/acs.analchem.9b02904
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dopamine (DA) is a monoamine neurotransmitter responsible for the maintenance of a variety of vital life functions. In vivo DA signaling occurs over multiple time scales, from subsecond phasic release due to dopamine neuron firing to tonic release responsible for long-term DA concentration changes over minutes to hours. Due to the complex, multifaceted nature of DA signaling, analytical sensing technology must be capable of recording DA from multiple locations and over multiple time scales. Decades of research has focused on improving in vivo detection capabilities for subsecond phasic DA, but the accurate detection of absolute resting DA levels in real time has proven challenging. We have developed a poly(3,4-ethylenedioxythiophene) (PEDOT)-based nanocomposite coating that exhibits excellent DA sensing capabilities for resting DA. PEDOT/functionalized carbon nanotube (PEDOT/CNT)-coated carbon fiber microelectrodes (CFEs) are capable of directly measuring resting DA using square wave voltammetry (SWV) with high sensitivity and selectivity. Incorporation of a PEDOT/CNT coating significantly increases the sensitivity for the detection of resting DA by a factor of 422. SWV measurements performed at Article PEDOT/CNT-functionalized CFEs implanted in the rat dorsal striatum reveal the absolute basal DA concentration to be 82 +/- 6 nM. Systemic administration of the dopamine transporter inhibitor nomifensine increases resting DA to a maximum 207 +/- 16 nM at 28 +/- 2 min following injection. PEDOT/CNT was also functionalized onto individual gold electrode sites along silicon microelectrode arrays (MEAs) to produce a multisite DA sensing electrode. MEA implantation allows for the quantification of basal DA from different brain regions with excellent spatial resolution. SWV detection paired with PEDOT/CNT functionalization is highly adaptable and shows great promise for tonic DA detection with high spatial and temporal resolution.
引用
收藏
页码:12917 / 12927
页数:11
相关论文
共 72 条
[21]   MATHEMATICAL RESOLUTION OF MIXED INVIVO VOLTAMMETRY SIGNALS - MODELS, EQUIPMENT, ASSESSMENT BY SIMULTANEOUS MICRODIALYSIS SAMPLING [J].
GONZALEZMORA, JL ;
GUADALUPE, T ;
FUMERO, B ;
MAS, M .
JOURNAL OF NEUROSCIENCE METHODS, 1991, 39 (03) :231-244
[22]   PHASIC VERSUS TONIC DOPAMINE RELEASE AND THE MODULATION OF DOPAMINE SYSTEM RESPONSIVITY - A HYPOTHESIS FOR THE ETIOLOGY OF SCHIZOPHRENIA [J].
GRACE, AA .
NEUROSCIENCE, 1991, 41 (01) :1-24
[23]   Dysregulation of the dopamine system in the pathophysiology of schizophrenia and depression [J].
Grace, Anthony A. .
NATURE REVIEWS NEUROSCIENCE, 2016, 17 (08) :524-+
[24]   In Vivo Monitoring of Dopamine by Microdialysis with 1 min Temporal Resolution Using Online Capillary Liquid Chromatography with Electrochemical Detection [J].
Gu, Hui ;
Varner, Erika L. ;
Groskreutz, Stephen R. ;
Michael, Adrian C. ;
Weber, Stephen G. .
ANALYTICAL CHEMISTRY, 2015, 87 (12) :6088-6094
[25]   Hormone-neurotransmitter interactions in the control of sexual behavior [J].
Hull, EM ;
Lorrain, DS ;
Du, JF ;
Matuszewich, L ;
Lumley, LA ;
Putnam, SK ;
Moses, J .
BEHAVIOURAL BRAIN RESEARCH, 1999, 105 (01) :105-116
[26]   Effect of Dexamethasone on Gliosis, Ischemia, and Dopamine Extraction during Microdialysis Sampling in Brain Tissue [J].
Jaquins-Gerstl, Andrea ;
Shu, Zhan ;
Zhang, Jing ;
Liu, Yansheng ;
Weber, Stephen G. ;
Michael, Adrian C. .
ANALYTICAL CHEMISTRY, 2011, 83 (20) :7662-7667
[27]   Comparison of the brain penetration injury associated with microdialysis and voltammetry [J].
Jaquins-Gerstl, Andrea ;
Michael, Adrian C. .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 183 (02) :127-135
[28]   Measurement of Basal Neurotransmitter Levels Using Convolution-Based Nonfaradaic Current Removal [J].
Johnson, Justin A. ;
Rodeberg, Nathan T. ;
Wightman, R. Mark .
ANALYTICAL CHEMISTRY, 2018, 90 (12) :7181-7189
[29]   Removal of Differential Capacitive Interferences in Fast-Scan Cyclic Voltammetry [J].
Johnson, Justin A. ;
Hobbs, Caddy N. ;
Wightnian, R. Mark .
ANALYTICAL CHEMISTRY, 2017, 89 (11) :6167-6175
[30]   Implantable microelectrode arrays for simultaneous electrophysiological and neurochemical recordings [J].
Johnson, Matthew D. ;
Franklin, Robert K. ;
Gibson, Matthew D. ;
Brown, Richard B. ;
Kipke, Daryl R. .
JOURNAL OF NEUROSCIENCE METHODS, 2008, 174 (01) :62-70