Volume rendering in the presence of partial volume effects

被引:29
作者
Souza, A [1 ]
Udupa, JK [1 ]
Saha, PK [1 ]
机构
[1] Univ Penn, Dept Radiol, Med Image Proc Grp, Philadelphia, PA 19104 USA
关键词
computed tomography (CT); partial volume effect; 3-D visualization; volume rendering;
D O I
10.1109/TMI.2004.840295
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In tomographic imagery, partial volume effects (PVEs) cause several artifacts in volume renditions. In X-ray computed tomography (CT), for example, soft-tissue-like pseudo structures appear in bone-to-air and bone-to-fat interfaces. Further, skin, which is identical to soft tissue in terms of CT number, obscures the rendition of the latter. The purpose of this paper is to demonstrate these phenomena and to provide effective solutions that yield significantly improved renditions. We introduce two methods that detect and classify voxels with PVE in X-ray CT. Further, a method is described to automatically peel skin so that PVE-resolved renditions of bone and soft tissue reveal considerably more detail. In the first method to address PVE, called the fraction measure (FM) method, the fraction of each tissue material in each voxel v is estimated by taking into account the intensities of the voxels neighboring v. The second method, called uncertainty principle (UP) method, is based on the following postulate (Saha and Udupa, 2001): In any acquired image, voxels with the highest uncertainty occur in the vicinity of object boundaries. The removal of skin is achieved by means of mathematical morphology. Volume renditions have been created before and after applying the methods for several patient CT datasets. A mathematical phantom experiment involving different levels of PVE has been conducted by adding different degrees of noise and blurring. A quantitative evaluation is done utilizing the mathematical phantom and clinical CT data wherein an operator carefully masked out voxels with PVE in the segmented images. All results have demonstrated the enhanced quality of display of bone and soft tissue after applying the proposed methods. The quantitative evaluations indicate that more than 98% of the voxels with PVE are removed by the two methods and the second method performs slightly better than the first. Further, skin peeling vividly reveals fine details in the soft tissue structures.
引用
收藏
页码:223 / 235
页数:13
相关论文
共 29 条
[1]  
ACKERMAN MJ, 1995, VISIBLE HUMAN PROJEC
[2]  
Beier J, 1998, RADIOLOGE, V38, P860, DOI 10.1007/s001170050435
[3]  
DEBOER M, 1997, P IEEE VIS 1997, P1
[4]   Volume rendering [J].
Drebin, Robert A. ;
Carpenter, Loren ;
Hanrahan, Pat .
Computer Graphics (ACM), 1988, 22 (04) :65-74
[5]   An order of magnitude faster isosurface rendering in software on a PC than using dedicated, general purpose rendering hardware [J].
Grevera, GJ ;
Udupa, JK ;
Odhner, D .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2000, 6 (04) :335-345
[6]   Reduced partial volume artifacts using spiral computed tomography and an integrating interpolator [J].
Heuscher, DJ ;
Vembar, M .
MEDICAL PHYSICS, 1999, 26 (02) :276-286
[7]  
HOHNE KH, 1992, J COMPUT ASSIST TOMO, V16, P285, DOI 10.1097/00004728-199203000-00019
[8]   Semi-automatic generation of transfer functions for direct volume rendering [J].
Kindlmann, G ;
Durkin, JW .
IEEE SYMPOSIUM ON VOLUME VISUALIZATION, 1998, :79-+
[9]   Multidimensional transfer functions for interactive volume rendering [J].
Kniss, J ;
Kindlmann, G ;
Hansen, C .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2002, 8 (03) :270-285
[10]   Partial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms [J].
Laidlaw, DH ;
Fleischer, KW ;
Barr, AH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (01) :74-86