Innovative seismic and energy retrofitting of wall envelopes using prefabricated textile-reinforced concrete panels with an embedded capillary tube system

被引:34
作者
Baek, E. [1 ]
Pohoryles, D. A. [2 ]
Kallioras, S. [2 ]
Bournas, D. A. [2 ,3 ]
Choi, H. [1 ]
Kim, T. [1 ]
机构
[1] Korea Construct & Transport Engn Dev Collaboratory, Yongin 17058, Gyeonggi Do, South Korea
[2] European Commiss, Joint Res Ctr JRC, Ispra, Italy
[3] European Commiss, JRC, Ispra, VA, Italy
关键词
Textile reinforced mortar (TRM); Textile capillary tube panel (TCP); Integrated seismic and energy retrofit; Infilled reinforced concrete (RC) frame; Unreinforced masonry (URM) wall; OF-THE-ART; INSULATION MATERIALS; MASONRY STRUCTURES; TRM; RC; MORTAR; FRP; BUILDINGS; COMPOSITES; BEHAVIOR;
D O I
10.1016/j.engstruct.2022.114453
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the experimental seismic performance of an innovative seismic-plus-energy retrofit solution for RC and URM structures. The intervention aims to simultaneously improve thermal efficiency and seismic safety of buildings with a light, cost-effective, and sustainable approach. The proposed hybrid retrofit system consists of prefabricated textile capillary-tube panels, mechanically connected through mortar or adhesives to existing building envelopes. This study assesses for the first time the seismic behaviour of such a system through quasi-static in-plane cyclic tests on three 3/5-scaled masonry-infilled RC frames. First, the response of a frame retrofitted with textile capillary-tube elements is compared with its two counterparts: a non-retrofitted frame and a frame retrofitted with textile-reinforced mortar and extruded polystyrene boards. Next, the paper demonstrates the application of the panels on three squat URM piers and presents preliminary but promising results from in-plane cyclic shear-compression tests. Overall, the retrofitted specimens exhibited considerably greater stiffness, strength, and displacement capacity than bare configurations. Furthermore, the panels proved to be equally effective in improving overall seismic response and controlling damage with established retrofit techniques based on textile-reinforced mortars. Finally, the thermal performance of the proposed integrated retrofitting system was assessed through in-situ experimentation on a real residential masonry building wall, exhibiting high efficiency.
引用
收藏
页数:16
相关论文
共 54 条
[1]   In-plane behavior of cavity masonry infills and strengthening with textile reinforced mortar [J].
Akhoundi, Farhad ;
Vasconcelos, Graca ;
Lourenco, Paulo ;
Silva, Luis M. ;
Cunha, Fernando ;
Fangueiro, Raul .
ENGINEERING STRUCTURES, 2018, 156 :145-160
[2]  
[Anonymous], 2020, ASTM E519/E519M-15, DOI DOI 10.1520/E0519_E0519M-15
[3]  
[Anonymous], 2017, L51052017 KAST KS
[4]   Life cycle analysis in the construction sector: Guiding the optimization of conventional Italian buildings [J].
Asdrubali, Francesco ;
Baldassarri, Catia ;
Fthenakis, Vasilis .
ENERGY AND BUILDINGS, 2013, 64 :73-89
[5]   Energy performance analysis of textile and capillary tube composite panel system by computational fluid dynamics and real-scale experiments [J].
Bae, Sangmu ;
Oh, Jinhwan ;
Kim, Jaemin ;
Baek, Eun-Rim ;
Nam, Yujin .
ENERGY AND BUILDINGS, 2022, 258
[6]   Numerical and experimental study on the use of microencapsulated phase change materials (PCMs) in textile reinforced concrete panels for energy storage [J].
Bahrar, Myriam ;
Djamai, Zakaria Ilyes ;
El Mankibi, Mohamed ;
Larbi, Amir Si ;
Salvia, Michelle .
SUSTAINABLE CITIES AND SOCIETY, 2018, 41 :455-468
[7]   Does seismic risk affect the environmental impact of existing buildings? [J].
Belleri, Andrea ;
Marini, Alessandra .
ENERGY AND BUILDINGS, 2016, 110 :149-158
[8]   A high-resolution geospatial assessment of the rooftop solar photovoltaic potential in the European Union [J].
Bodis, Katalin ;
Kougias, Ioannis ;
Jager-Waldau, Arnulf ;
Taylor, Nigel ;
Szabo, Sandor .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2019, 114
[9]   Concurrent seismic and energy retrofitting of RC and masonry building envelopes using inorganic textile-based composites combined with insulation materials: A new concept [J].
Bournas, Dionysios A. .
COMPOSITES PART B-ENGINEERING, 2018, 148 :166-179
[10]  
Calvi G.M., 2016, Multi-hazard Approaches to Civil Infrastructure Engineering, P165, DOI [10.1007/978-3-319-29713-2_9, DOI 10.1007/978-3-319-29713-2_9]