Optimization of the separation of malachite green in water by capillary electrophoresis Raman spectroscopy (CE-RS) based on the stacking and sweeping modes

被引:54
作者
Tsai, Chih-Hsin [1 ]
Lin, Jia-Der [1 ]
Lin, Cheng-Huang [1 ]
机构
[1] Natl Taiwan Normal Univ, Dept Chem, Taipei, Taiwan
关键词
capillary electrophoresis; Raman spectroscopy; malachite green; crystal violet; stacking; sweeping;
D O I
10.1016/j.talanta.2006.10.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary electrophoresis Raman spectroscopy (CE-RS) method based on the stacking and sweeping modes are described. A non-fluorescent compound (malachite green, MG; crystal violet, CV) and a doubled Nd:YAG laser (532 nm, 300 mW) were selected as the model compound and light source, respectively. In order to carry out a quantitative and analysis of MG, a monochromator was used to collect the specific Raman line at 1616 cm(-1) (the N-phi and C-C stretching, corresponding to 582 nm when the wavelength of the exciting source is 532 nm). The limit of detection (LOD) for MG was 1.6 x 10(-5) and 1.1 X 10(-5) M, respectively, based on the CZE and MEKC modes. This could be improved to 3.4 x 10(-7) and 5.3 x 10(-9) M, respectively, when the stacking and sweeping modes were applied. The method was also extended to the determination of MG in an actual sample. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:368 / 372
页数:5
相关论文
共 27 条
[1]   On-line focusing of flavin derivatives using dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection [J].
Britz-McKibbin, P ;
Otsuka, K ;
Terabe, S .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3736-3743
[2]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[3]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[4]   RAMAN-SPECTROSCOPIC DETECTION SYSTEM FOR CAPILLARY ZONE ELECTROPHORESIS [J].
CHEN, CY ;
MORRIS, MD .
APPLIED SPECTROSCOPY, 1988, 42 (03) :515-518
[5]  
Chien R. L., 1992, ANAL CHEM, V64, P489
[6]  
DeVault GL, 2001, ELECTROPHORESIS, V22, P2303, DOI 10.1002/1522-2683(20017)22:11<2303::AID-ELPS2303>3.0.CO
[7]  
2-A
[8]   Capillary electrophoresis coupled on-line with ultraviolet resonance Raman spectroscopy [J].
Dijkstra, RJ ;
Efremov, EV ;
Ariese, F ;
Brinkman, UAT ;
Gooijer, C .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5697-5702
[9]   On-line identification method in column liquid chromatography: UV resonance Raman spectroscopy [J].
Dijkstra, RJ ;
Martha, CT ;
Ariese, F ;
Brinkman, UAT ;
Gooijer, C .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4977-4982
[10]   On-line coupling of column liquid chromatography and raman spectroscopy using a liquid core waveguide [J].
Dijkstra, RJ ;
Bader, AN ;
Hoornweg, GP ;
Brinkman, UAT ;
Gooijer, C .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4575-4579