Automated volumetry of solid pulmonary nodules in a phantom -: Accuracy across different CT scanner technologies

被引:40
作者
Das, Marco
Muehlenbruch, Georg
Katoh, Markus
Bakai, Annemarie
Salganicoff, Marcos
Stanzel, Sven
Mahnken, Andreas H.
Guenther, Rolf W.
Wildberger, Joachim E.
机构
[1] Univ Aachen, Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-52072 Aachen, Germany
[2] Siemens Med Solut, CT Div, Forchheim, Germany
[3] Siemens Med Solut, CAD Applicat, Malvern, PA USA
[4] Univ Aachen, Rhein Westfal TH Aachen, Inst Med Stat, D-52072 Aachen, Germany
[5] Univ Aachen, Rhein Westfal TH Aachen, Helmholtz Inst, D-52072 Aachen, Germany
关键词
pulmonary nodule; volumetry; computer-aided diagnosis; phantom; spiral CT; multidetector-row CT;
D O I
10.1097/01.rli.0000258683.20123.c4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The accuracy of automated volumetry for pulmonary nodules in a phantom using different CT scanner technologies from single-slice spiral CT (SSCT) to 64-slice multidetector-row CT (MDCT) was compared. Materials and Methods: A lung phantom with 5 different categories of pulmonary nodules was scanned using a single-slice spiral CT, a 4-slice MDCT, a 16-slice MDCT and a 64-slice MDCT. Each category comprised of 7-9 nodules each (total n = 40) with different known volumes. Standard dose and low dose protocols were performed using thin and thick collimation. Image data were reconstructed at the thinnest slice thickness. Data sets were analyzed with a dedicated volumetry software. Volumes of all nodules were calculated and compared. Results: Mean absolute percentage error (APE) for all nodules was 8.65% (+/- 7.29%) for the SSCT, 10.26% (+/- 8.25%) for the 4-slice MDCT, 8.19% (+/- 7.57%) for the 16-slice MDCT and 7.89% (+/- 7.39%) for the 64-slice MDCT. There was statistically significant influence of the scanner type, protocol, anatomic location, and nodule volume on APE, but overall, APEs were comparable. Conclusion: Computer-aided volumetry showed accurate measurements in all tested scanner types. This finding has important implications for nodule assessment and follow-up.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 26 条
  • [1] Interobserver and intraobserver variability in the assessment of pulmonary nodule size on CT using film and computer display methods
    Bogot, NR
    Kazerooni, EA
    Kelly, AM
    Quint, LE
    Desjardins, B
    Nan, B
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (08) : 948 - 956
  • [2] Volumetric assessment of pulmonary nodules with ECG-gated MDCT
    Boll, DT
    Gilkeson, RC
    Fleiter, TR
    Blackham, KA
    Duerk, JL
    Lewin, JS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) : 1217 - 1223
  • [3] Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs
    Bolte, H
    Riedel, C
    Jahnke, T
    Inan, N
    Freitag, S
    Kohl, G
    Heller, M
    Biederer, J
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (01) : 28 - 35
  • [4] Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers
    Diederich, S
    Wormanns, D
    Semik, M
    Thomas, M
    Lenzen, H
    Roos, N
    Heindel, W
    [J]. RADIOLOGY, 2002, 222 (03) : 773 - 781
  • [5] Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
    Erasmus, JJ
    Gladish, GW
    Broemeling, L
    Sabloff, BS
    Truong, MT
    Herbst, RS
    Munden, RF
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (13) : 2574 - 2582
  • [6] Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy
    Goo, JM
    Tongdee, T
    Tongdee, R
    Yeo, K
    Hildebolt, CF
    Bae, KT
    [J]. RADIOLOGY, 2005, 235 (03) : 850 - 856
  • [7] Henschke CI, 2001, CANCER, V92, P153, DOI 10.1002/1097-0142(20010701)92:1<153::AID-CNCR1303>3.0.CO
  • [8] 2-S
  • [9] Early Lung Cancer Action Project: overall design and findings from baseline screening
    Henschke, CI
    McCauley, DI
    Yankelevitz, DF
    Naidich, DP
    McGuinness, G
    Miettinen, OS
    Libby, DM
    Pasmantier, MW
    Koizumi, J
    Altorki, NK
    Smith, JP
    [J]. LANCET, 1999, 354 (9173) : 99 - 105
  • [10] Effect of blood vessels on measurement of nodule volume in a chest phantom
    Ko, JP
    Marcus, R
    Bomsztyk, E
    Babb, JS
    Stefanescu, C
    Kaur, M
    Naidich, DP
    Rusinek, H
    [J]. RADIOLOGY, 2006, 239 (01) : 79 - 85