Daylighting and energy analysis of multi-sectional facades

被引:24
作者
Chan, Ying-Chieh [1 ]
Tzempelikos, Athanasios [1 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
来源
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015) | 2015年 / 78卷
关键词
Dynamic facades; Shading; Light-redirect devices; Daylighting; Energy; CONTROL STRATEGIES; GLARE PROTECTION; ROLLER SHADES; PERFORMANCE; BLINDS; SYSTEM;
D O I
10.1016/j.egypro.2015.11.138
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Previous studies on dynamic facades have focused on a single type of section/shading, investigating its properties or control in order to improve comfort or reduce energy use for lighting and air-conditioning. Multi-sectional dynamic facade concepts are able to balance daylight provision and energy use reduction versus maintaining comfort levels. However, the overall potential of such systems needs to be investigated in an integrated manner. A typical multi-sectional facade consists of a top section, representing the non-viewing (daylighting) part, a main middle (viewing) section and a spandrel section. The top section can transmit daylight deeper into the space and the middle section should provide direct outside view (or privacy) and protect from glare and sunlight. The two sections may have different areas, glazing properties, and shading types and control options. This paper investigates the concept and quantifies the impact of combinations of solar protection and light redirecting devices. The analysis includes two climates and two orientations to serve as a preliminary study to assist in design guidelines for multi-sectional facades. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 2003, 150992003 ISO
[2]   A systematic method for selecting roller shade properties for glare protection [J].
Chan, Ying-Chieh ;
Tzempelikos, Athanasios ;
Konstantzos, Iason .
ENERGY AND BUILDINGS, 2015, 92 :81-94
[3]   Efficient venetian blind control strategies considering daylight utilization and glare protection [J].
Chan, Ying-Chieh ;
Tzempelikos, Athanasios .
SOLAR ENERGY, 2013, 98 :241-254
[4]   A hybrid ray-tracing and radiosity method for calculating radiation transport and illuminance distribution in spaces with venetian blinds [J].
Chan, Ying-Chieh ;
Tzempelikos, Athanasios .
SOLAR ENERGY, 2012, 86 (11) :3109-3124
[5]   PERFORMANCE OF LASER CUT LIGHT DEFLECTING PANELS IN DAYLIGHTING APPLICATIONS [J].
EDMONDS, IR .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 1993, 29 (01) :1-26
[6]  
Fernandes L.L., 2013, ENERGY BUILD, V61, P8
[7]   Daylighting and solar shading performances of an innovative automated reflective louvre system [J].
Hashemi, Arman .
ENERGY AND BUILDINGS, 2014, 82 :607-620
[8]   Illuminance-based slat angle selection model for automated control of split blinds [J].
Hu, Jia ;
Olbina, Svetlana .
BUILDING AND ENVIRONMENT, 2011, 46 (03) :786-796
[9]  
Kakham P, 2013, P 2013 INT C ALT EN
[10]  
Kotey NA, 2009, ASHRAE TRAN, V115, P145