The paper describes sensorless control of the permanent magnet motor at low speed. A rotor position is obtained by the HPI method, which uses test voltage steps. During test voltage step, no electromagnetic torque is produced. A special control method is required at low speed. This paper contains a description of impact of the control method on the electromagnetic torque. (Analysis of the starting torque in permanent magnet motor controlled by HPI method).