In vivo Bone Position Measurement Using High-Frequency Ultrasound Validated with 3-D Optical Motion Capture Systems: A Feasibility Study

被引:25
作者
Giannetti, Romano [1 ]
Petrella, Anthony [2 ]
Bach, Joel [2 ]
Silverman, Anne K. [2 ]
Saenz-Nuno, M. A. [1 ]
Perez-Mallada, N. [1 ]
机构
[1] Pontifical Comillas Univ, Madrid, Spain
[2] Colorado Sch Mines, Golden, CO 80401 USA
关键词
Bone position; Skeletal position tracking; Biomechanical measurement; Biomedical transducers; Ultrasonic transducer; LOCALIZATION; MOVEMENT;
D O I
10.1007/s40846-017-0273-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate measurement of bone position in vivo during dynamic activities has the potential to improve our identification and understanding of injury mechanisms and enhance our ability to design protective equipment and/or devices for rehabilitation and human augmentation. Existing technologies such as skin-mounted reflective markers and fluoroscopy are limited either in accuracy or portability. The purpose of this study was to demonstrate a proof of concept for an ultrasound (US) sensor array to measure bone positions around a human joint in vivo. A single off-the-shelf US sensor was tested for repeatability and accuracy in measuring soft tissue depth between the skin surface and embedded bone with (a) a gelatinous analog for human tissue, and (b) a porcine leg specimen. In measuring the hydrogel analog the sensor was able to measure depth with a repeatability of 0.25 mm. In measuring the porcine leg specimen, measurement accuracy was compared to a Qualisys optical motion capture system with accuracy on the order of 0.5 mm, and the US measurement uncertainty was found to be 1.1 mm. An additional set of tests on a similar system performed on a human participant performing elbow flexion/extension confirms that the method is usable for evaluating both the bone position and the muscle volume during movement analysis measurements. This study demonstrates that low cost off-the-shelf US sensors have acceptable quality to measure bone positions accurately in vivo.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 18 条
  • [1] In vitro measurement of the restraining role of the anterior cruciate ligament during walking and stair ascent
    Ahmed, AM
    McLean, C
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (06): : 768 - 779
  • [2] Biomechanical ToolKit: Open-source framework to visualize and process biomechanical data
    Barre, Arnaud
    Armand, Stephane
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 114 (01) : 80 - 87
  • [3] Comparative analysis of speed's impact on muscle demands during partial body weight support motor-assisted elliptical training
    Burnfield, Judith M.
    Irons, Sonya L.
    Buster, Thad W.
    Taylor, Adam P.
    Hildner, Gretchen A.
    Shu, Yu
    [J]. GAIT & POSTURE, 2014, 39 (01) : 314 - 320
  • [4] Carson P., 2000, CATEGORICAL COURSE D, P9
  • [5] IMPEDANCE AND ATTENUATION PROFILE ESTIMATION OF MULTILAYERED MATERIAL FROM REFLECTED ULTRASOUND
    CHEN, TS
    HO, B
    ZAPP, HR
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (04) : 787 - 791
  • [6] Comparison of different calculations of three-dimensional joint kinematics from video-based system data
    Chèze, L
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (12) : 1695 - 1699
  • [7] EXPERIMENTAL-DATA ACQUISITION-SYSTEM FOR ULTRASOUND IMAGING
    CHOW, CK
    WANG, SSM
    KANEKO, T
    PERRY, TR
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1979, 28 (01) : 79 - 83
  • [8] Low-Frequency Ultrasound in Medicine: An In Vivo Evaluation
    Fiorillo, Antonino S.
    Grimaldi, Domenico
    Paolino, Donatella
    Pullano, Salvatore A.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (06) : 1658 - 1663
  • [9] Giannetti R, 2015, IEEE IMTC P, P762, DOI 10.1109/I2MTC.2015.7151364
  • [10] Giaquinto N., 2015, P 2015 INT INSTR MEA, P178