Intramedullary nailing of the lower extremity: Biomechanics and biology

被引:151
作者
Bong, Matthew R.
Kummer, Frederick J.
Koval, Kenneth J.
Egol, Kenneth A.
机构
[1] NYU, Hosp Joint Dis, Musculoskeletal Res Ctr, New York, NY 10003 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Orthopaed Surg, Lebanon, NH 03766 USA
[3] NYU, Hosp Joint Dis, Dept Orthopaed Surg, Fracture Serv, New York, NY 10003 USA
关键词
BONE BLOOD-FLOW; TIBIAL SHAFT; FAT INTRAVASATION; FEMORAL-SHAFT; FRACTURE; PRESSURE; STRENGTH; FEMUR; STABILITY; DIAPHYSIS;
D O I
10.5435/00124635-200702000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The intramedullary nail or rod is commonly used for long-bone fracture fixation and has become the standard treatment of most long-bone diaphyseal and selected metaphyseal fractures. To best understand use of the intramedullary nail, a general knowledge of nail biomechanics and biology is helpful. These implants are introduced into the bone remote to the fracture site and share compressive, bending, and torsional loads with the surrounding osseous structures. Intramedullary nails function as internal splints that allow for secondary fracture healing. Like other metallic fracture fixation implants, a nail is subject to fatigue and can eventually break if bone healing does not occur. Intrinsic characteristics that affect nail biomechanics include its material properties, cross-sectional shape, anterior bow, and diameter. Extrinsic factors, such as reaming of the medullary canal, fracture stability (comminution), and the use and location of locking bolts also affect fixation biomechanics. Although reaming and the insertion of intramedullary nails can have early deleterious effects on endosteal and cortical blood flow, canal reaming appears to have several positive effects on the fracture site, such as increasing extraosseous circulation, which is important for bone healing.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 57 条
[41]   Effect of acute reamed versus unreamed intramedullary nailing on compartment pressure when treating closed tibial shaft fractures: A randomized prospective study [J].
Nassif, JM ;
Gorczyca, JT ;
Cole, JK ;
Pugh, KJ ;
Pienkowski, D .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (08) :554-558
[42]   Nailing versus plating in thoracic trauma: An experimental study in sheep [J].
Neudeck, F ;
Wozasek, GE ;
Obertacke, U ;
Thurnher, M ;
Schlag, G .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 40 (06) :980-984
[43]   INFLUENCES OF DIFFERENT METHODS OF INTRAMEDULLARY FEMORAL NAILING ON LUNG-FUNCTION IN PATIENTS WITH MULTIPLE TRAUMA [J].
PAPE, HC ;
REGEL, G ;
DWENGER, A ;
KRUMM, K ;
SCHWEITZER, G ;
KRETTEK, C ;
STURM, JA ;
TSCHERNE, H .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 35 (05) :709-716
[44]  
Powell JN, 2003, J BONE JOINT SURG AM, V85A, P2093
[45]  
Russell T A, 1991, J Orthop Trauma, V5, P332, DOI 10.1097/00005131-199109000-00013
[46]   CORTICAL BONE BLOOD-FLOW IN REAMED AND UNREAMED LOCKED INTRAMEDULLAR NAILING - A FRACTURED TIBIA MODEL IN SHEEP [J].
SCHEMITSCH, EH ;
KOWALSKI, MJ ;
SWIONTKOWSKI, MF ;
SENFT, D .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (05) :373-382
[47]   Soft-tissue blood flow following reamed versus unreamed locked intramedullary nailing: A fractured sheep tibia model [J].
Schemitsch, EH ;
Kowalski, MJ ;
Swiontkowski, MF .
ANNALS OF PLASTIC SURGERY, 1996, 36 (01) :70-75
[48]   COMPARISON OF THE EFFECT OF REAMED AND UNREAMED LOCKED INTRAMEDULLARY NAILING ON BLOOD-FLOW IN THE CALLUS AND STRENGTH OF UNION FOLLOWING FRACTURE OF THE SHEEP TIBIA [J].
SCHEMITSCH, EH ;
KOWALSKI, MJ ;
SWIONTKOWSKI, MF ;
HARRINGTON, RM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (03) :382-389
[49]   Bone morphogenetic protein-2 coating of titanium implants increases biomechanical strength and accelerates bone remodeling in fracture treatment: A biomechanical and histological study in rats [J].
Schmidmaier, G ;
Wildemann, B ;
Cromme, F ;
Kandziora, F ;
Haas, NP ;
Raschke, M .
BONE, 2002, 30 (06) :816-822
[50]  