Comparison between polystyrene and fiberglass roof insulation in warm and cold climates

被引:61
作者
Al-Sallal, KA [1 ]
机构
[1] United Arab Emirates Univ, Dept Architectural Engn, Al Ain, U Arab Emirates
关键词
life-cycle cost; payback time; law of diminishing returns; energy conservation; thermal resistance;
D O I
10.1016/S0960-1481(02)00065-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study clarifies the law of diminishing returns when improving the conservation level of residential buildings by using case studies simulation. It explores the effect of different climates on the decision of selecting the insulation type and thickness. It shows the importance of using the life-cycle cost model on the decision of adding more insulation levels and knowing when to stop. RENCON program was employed to estimate the annual heating and cooling requirements of a 108 m(2) house. The analysis was carried out for several cases of two types of roof insulation (polystyrene and fiberglass) in two different locations (College Station, Texas and Minneapolis, Minnesota.) R5 was found to be the most cost effective thermal resistance in polystyrene in both locations. In fiberglass, R10 was the most cost effective. It was found that investing money to improve the insulation levels in the cold climate house has better returns than that of the warm climate. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 4 条
[1]  
Balcomb J.D., 1984, PASSIVE SOLAR HEATIN
[2]  
DEGELMAN L, 1991, RENCON PROGRAM ENERG
[3]  
HOKE JR, 1988, ARCHITECTURAL GRAPHI
[4]  
Lechner N., 1991, HEATING COOLING LIGH