Effects of various operating and initial conditions on cold start performance of polymer electrolyte membrane fuel cells

被引:126
作者
Jiao, Kui [1 ]
Li, Xianguo [1 ]
机构
[1] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cold start; Polymer electrolyte membrane fuel cell; Three-dimensional multiphase model; Heating-up time; Water freezing; THERMAL-MODEL; LIQUID WATER; PEMFC; PEFC;
D O I
10.1016/j.ijhydene.2009.07.102
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cold start is a challenging and important issue that hinders the commercialization of polymer electrolyte membrane fuel cell (PEMFC). In this study, a three-dimensional multiphase model has been developed to simulate the cold start processes in a PEMFC. Numerical simulations have been conducted for a single PEMFC starting at various operating and initial conditions, which are cell voltages, initial water contents and distributions, anode inlet relative humidity (RH), surrounding heat transfer coefficients, and cell temperatures. It is found that the heating-up time can be significantly reduced by decreasing the cell voltage and effective purge is critical for PEMFC cold start. The largest heating source at high cell voltages is the activational heat, and it becomes the ohmic heat at low cell voltages. The water freezing in the membrane is not observed when the cell is producing current due to the heat generation and the slow water diffusion into the membrane at subzero temperatures, and it is only observed after the cold start is failed, further confirming the importance of purge. Humidification of the supplied hydrogen has negligible effect on the cold start performance since only small amounts of water vapour can be taken by the gas streams at subzero temperatures. The surrounding heat transfer coefficients have significant influence on the heating-up time, indicating the importance of cell insulation or heating. The rate of cell heating up is reduced when the startup temperature is lowered due to the more sluggish electrochemical reaction kinetics. (c) 2009 Professor T. Nejat veziroglu. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:8171 / 8184
页数:14
相关论文
共 25 条
[11]   One-dimensional thermal model of cold-start in a polymer electrolyte fuel cell stack [J].
Khandelwal, Manish ;
Lee, Sungho ;
Mench, M. M. .
JOURNAL OF POWER SOURCES, 2007, 172 (02) :816-830
[12]  
Kurz W., 1986, Fundamentals of solidification, V4th
[13]   A multiphase model for cold start of polymer electrolyte fuel cells [J].
Mao, Leng ;
Wang, Chao-Yang ;
Tabuchi, Yuichiro .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2007, 154 (03) :B341-B351
[14]   Analysis of cold start in polymer electrolyte fuel cells [J].
Mao, Leng ;
Wang, Chao-Yang .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2007, 154 (02) :B139-B146
[15]   Numerical analyses of non-isothermal self-start behaviors of PEM fuel cells from subfreezing startup temperatures [J].
Meng, Hua .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2008, 33 (20) :5738-5747
[16]   A PEM fuel cell model for cold-start simulations [J].
Meng, Hua .
JOURNAL OF POWER SOURCES, 2008, 178 (01) :141-150
[17]   Heat effects and rates and molecular mechanisms of water sorption by perfluorinated polymer materials bearing functional groups [J].
Ostrovskii, VE ;
Gostev, BV .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 1996, 46 (02) :397-416
[18]   Low temperature operation and influence parameters on the cold start ability of portable PEMFCs [J].
Oszcipok, M ;
Zedda, M ;
Riemann, D ;
Geckeler, D .
JOURNAL OF POWER SOURCES, 2006, 154 (02) :404-411
[19]   Polymer electrolyte fuel cell stack thermal model to evaluate sub-freezing startup [J].
Sundaresan, M ;
Moore, RM .
JOURNAL OF POWER SOURCES, 2005, 145 (02) :534-545
[20]   Effects of operating and design parameters on PEFC cold start [J].
Tajiri, Kazuya ;
Tabuchi, Yuichiro ;
Kagami, Fumio ;
Takahashi, Shinichi ;
Yoshizawa, Koudai ;
Wang, Chao-Yang .
JOURNAL OF POWER SOURCES, 2007, 165 (01) :279-286