A Three-Dimensional Variable-Density Spiral Spatial-Spectral RF Pulse With Rotated Gradients

被引:5
作者
Deng, Weiran [1 ]
Stenger, V. Andrew [1 ]
机构
[1] Univ Hawaii, UH QMC Magnet Resonance Res Ctr, John A Burns Sch Med, Dept Med, Honolulu, HI 96813 USA
基金
美国国家卫生研究院;
关键词
multi-dimensional RF pulses; spatial-spectral excitation; variable-density spirals; UNFOLD; lipid imaging; SELECTIVE EXCITATION; TRAJECTORIES; UNFOLD; SENSE; MRI;
D O I
10.1002/mrm.22209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional spatial-spectral radiofrequency pulses using a stack-of-spirals trajectory can achieve two-dimensional spatial localization and one-dimensional spectral selection simultaneously. These pulses are useful, for example, in reduced field-of-view applications that also require frequency specificity such as lipid imaging. A limitation of the pulse design is that the length of the spiral trajectory is fixed by the frequency separation of lipid and water. This restricts the highest possible excitation resolution of the spatial profile over a given field of excitation. In this work, we examine the use of periodically rotated variable-density spirals to increase the spatial excitation resolution without changing the frequency selectivity. Variable-density spirals are used to under-sample the high spatial frequencies such that higher excitation resolutions can be obtained with a small expense in increased aliasing of the slice profile. The periodic rotation of the spiral trajectories reduces the impact of the under-sampling by distributing the aliasing in the frequency domain. The technique is demonstrated with simulations, phantom studies, and imaging human leg muscle at 3 T. It was found in the human study that the spatial excitation resolution could be improved from 6 x 6 to 8 x 8 (matrix size over a fixed field of view) while decreasing aliasing by approximately 40-60%. Magn Reson Med 63:828-834, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:828 / 834
页数:7
相关论文
共 23 条
[1]   Semi-automated segmentation and quantification of adipose tissue in calf and thigh by MRI: A preliminary study in patients with monogenic metabolic syndrome [J].
Al-Attar S.A. ;
Pollex R.L. ;
Robinson J.F. ;
Miskie B.A. ;
Walcarius R. ;
Rutt B.K. ;
Hegele R.A. .
BMC Medical Imaging, 6 (1)
[2]   2D-RF-pulse-encoded curved-slice imaging [J].
Börnert, P .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2003, 16 (02) :86-92
[3]  
Goodpaster BH, 2004, AM J CLIN NUTR, V79, P748
[4]   SPATIAL LOCALIZATION IN 2 DIMENSIONS USING NMR DESIGNER PULSES [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03) :647-654
[5]   Transmit SENSE [J].
Katscher, U ;
Börnert, P ;
Leussler, C ;
van den Brink, JS .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :144-150
[6]  
Liang Z-P, 1992, REV MAGN RESON MED, V4, P67
[7]   Reduction of motion artifacts in cine MRI using variable-density spiral trajectories [J].
Liao, JR ;
Pauly, JM ;
Brosnan, TJ ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :569-575
[8]  
Madore B, 1999, MAGNET RESON MED, V42, P813, DOI 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO
[9]  
2-S
[10]   SIMULTANEOUS SPATIAL AND SPECTRAL SELECTIVE EXCITATION [J].
MEYER, CH ;
PAULY, JM ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (02) :287-304