The Mark Coventry Award Articular Contact Estimation in TKA Using In Vivo Kinematics and Finite Element Analysis

被引:45
|
作者
Catani, Fabio [2 ]
Innocenti, Bernardo [1 ]
Belvedere, Claudio [3 ]
Labey, Luc [1 ]
Ensini, Andrea [2 ]
Leardini, Alberto [3 ]
机构
[1] Smith & Nephew, European Ctr Knee Res, Louvain, Belgium
[2] Ist Ortoped Rizzoli, Dept Orthoped Surg, Bologna, Italy
[3] Ist Ortoped Rizzoli, Movement Anal Lab, Bologna, Italy
关键词
TOTAL KNEE ARTHROPLASTY; ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS; CONDYLAR LIFT-OFF; FLUOROSCOPIC ANALYSIS; GAIT ANALYSIS; REPLACEMENT; MOTION; ROTATION;
D O I
10.1007/s11999-009-0941-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In vivo fluoroscopy is a well-known technique to analyze joint kinematics of the replaced knee. With this method, however, the contact areas between femoral and tibial components, fundamental for monitoring wear and validating design concepts, are hard to identify. We developed and tested a novel technique to assess condylar and post-cam contacts in TKA. The technique uses in vivo motion data of the replaced knee from standard fluoroscopy as input for finite element models of the prosthesis components. In these models, tibiofemoral contact patterns at the condyles and post-cam articulations were calculated during various activities. To test for feasibility, the technique was applied to a bicruciate posterior-stabilized prosthesis. Sensitivity of the finite element analysis, validation of the technique, and in vivo tests were performed. To test for potential in the clinical setting, five patients were preliminarily analyzed during chair rising-sitting, stair climbing, and step up-down. For each task and patient, the condylar contact points and contact line rotation were calculated. The results were repeatable and consistent with corresponding calculations from traditional fluoroscopic analysis. Specifically, natural knee kinematics, which shows rolling back and screw home, seemed replicated in all motor tasks. Post-cam contact was observed on both the anterior and posterior faces. Anterior contact is limited to flexion angle close to extension; posterior contact occurs in deeper flexion but is dependent on the motor task. The data suggest the proposed technique provides reliable information to analyze post-cam contacts.
引用
收藏
页码:19 / 28
页数:10
相关论文
共 6 条
  • [1] The Mark Coventry Award Diagnosis of Early Postoperative TKA Infection Using Synovial Fluid Analysis
    Bedair, Hany
    Ting, Nicholas
    Jacovides, Christina
    Saxena, Arjun
    Moric, Mario
    Parvizi, Javad
    Della Valle, Craig J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (01) : 34 - 40
  • [2] The 2011 ABJS']JS Nicolas Andry Award: 'Lab'-in-a-Knee: In Vivo Knee Forces, Kinematics, and Contact Analysis
    D'Lima, Darryl D.
    Patil, Shantanu
    Steklov, Nicolai
    Colwell, Clifford W., Jr.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (10) : 2953 - 2970
  • [3] The Influence of Talar Displacement on Articular Contact Mechanics: A 3D Finite Element Analysis Study Using Weightbearing Computed Tomography
    Peiffer, Matthias
    Lewis, Lauren
    Xie, Katherine
    Guild, Theodore T.
    Ashkani-Esfahani, Soheil
    Kwon, John
    FOOT & ANKLE INTERNATIONAL, 2024, 45 (04) : 393 - 405
  • [4] Optimization of parameters for femoral component implantation during TKA using finite element analysis and orthogonal array testing
    Mou, Zhifang
    Dong, Wanpeng
    Zhang, Zhen
    Wang, Aohan
    Hu, Guanghong
    Wang, Bing
    Dong, Yuefu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [5] Computational modeling of polyethylene wear in total hip arthroplasty using patient-specific kinematics-coupled finite element analysis
    Peng, Yun
    Arauz, Paul
    An, Shuai
    Kwon, Young-Min
    TRIBOLOGY INTERNATIONAL, 2019, 129 : 162 - 166
  • [6] Estimation of the effects of inset heights and slit configurations in an acetabular cup on the pull-out behavior of an artificial hip joint with a structure for preventing dislocation using finite element analysis
    Kawamura, Yuki
    Ohmasa, Mitsushi
    Kobayashi, Takayuki
    Matsufuji, Yoshihito
    Saito, Makoto
    Uwa, Yoshinori
    Washio, Saiji
    Yamamoto, Ei
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (10) : 2587 - 2601