Three-Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta-Analysis

被引:28
作者
Rong, Lisa Q. [1 ]
Hameed, Irbaz [2 ]
Salemi, Arash [2 ]
Rahouma, Mohamed [2 ]
Khan, Faiza M. [2 ]
Wijeysundera, Harindra C. [3 ]
Angiolillo, Dominick J. [4 ]
Shore-Lesserson, Linda [5 ]
Biondi-Zoccai, Giuseppe [6 ,7 ]
Girardi, Leonard N. [2 ]
Fremes, Stephen E. [3 ]
Gaudino, Mario [2 ]
机构
[1] Weill Cornell Med, Dept Anesthesiol, 525 East 68th St,M324, New York, NY 10065 USA
[2] Weill Cornell Med, Dept Cardiothorac Surg, New York, NY USA
[3] Univ Toronto, Schulich Heart Ctr, Sunnybrook Hlth Sci, Toronto, ON, Canada
[4] Univ Florida, Coll Med, Div Cardiol, Jacksonville, FL USA
[5] North Shore Univ Hosp, Dept Anesthesiol, Manhasset, NY USA
[6] Sapienza Univ Rome, Dept Medicosurg Sci & Biotechnol, Latina, Italy
[7] Mediterranea Cardioctr, Naples, Italy
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2019年 / 8卷 / 19期
关键词
multidetector row computed tomography; transesophageal echocardiography; transfemoral aortic valve implantation; MULTIDETECTOR COMPUTED-TOMOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ANNULUS; ACCURACY; ROOT; REGURGITATION; STENOSIS; CT; IMPLANTATION; SOFTWARE;
D O I
10.1161/JAHA.119.013463
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Transcatheter aortic valve replacement (TAVR) is the standard of care for many patients with severe symptomatic aortic stenosis and relies on accurate sizing of the aortic annulus. It has been suggested that 3-dimensional transesophageal echocardiography (3D TEE) may be used instead of multidetector computed tomography (MDCT) for TAVR planning. This systematic review and meta-analysis compared 3D TEE and MDCT for pre-TAVR measurements. Methods and Results-A systematic literature search was performed. The primary outcome was the correlation coefficient between 3D TEE- and MDCT-measured annular area. Secondary outcomes were correlation coefficients for mean annular diameter, annular perimeter, and left ventricular outflow tract area; interobserver and intraobserver agreements; mean differences between 3D TEE and MDCT measurements; and pooled sensitivities, specificities, and receiver operating characteristic area under curve values of 3D TEE and MDCT for discriminating post-TAVR paravalvular aortic regurgitation. A random effects model was used. Meta-regression and leave-one-out analysis for the primary outcome were performed. Nineteen studies with a total of 1599 patients were included. Correlations between 3D TEE and MDCT annular area, annular perimeter, annular diameter, and left ventricular outflow tract area measurements were strong (0.86 [95% CI, 0.80-0.90]; 0.89 [CI, 0.82-0.93]; 0.80 [CI, 0.70-0.87]; and 0.78 [CI, 0.61-0.88], respectively). Mean differences between 3D TEE and MDCT between measurements were small and nonsignificant. Interobserver and intraobserver agreement and discriminatory abilities for paravalvular aortic regurgitation were good for both 3D TEE and MDCT. Conclusions-For pre-TAVR planning, 3D TEE is comparable to MDCT. In patients with renal dysfunction, 3D TEE may be potentially advantageous for TAVR measurements because of the lack of contrast exposure.
引用
收藏
页数:34
相关论文
共 38 条
  • [31] Transcatheter Aortic Valve Replacement 2016 A Modern-Day "Through the Looking-Glass" Adventure
    Vahl, Torsten P.
    Kodali, Susheel K.
    Leon, Martin B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (12) : 1472 - 1487
  • [32] Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing
    Vaquerizo, Beatriz
    Spaziano, Marco
    Alali, Juwairia
    Mylote, Darren
    Theriault-Lauzier, Pascal
    Alfagih, Rashed
    Martucci, Giuseppe
    Buithieu, Jean
    Piazza, Nicolo
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (01) : 15 - 23
  • [33] Conducting Meta-Analyses in R with the metafor Package
    Viechtbauer, Wolfgang
    [J]. JOURNAL OF STATISTICAL SOFTWARE, 2010, 36 (03): : 1 - 48
  • [34] Wells GA, 2000, NEWCASTLE OTTAWA SCA
  • [35] Intraprocedural TAVR Annulus Sizing Using 3D TEE and the "Turnaround Rule"
    Wiley, Brandon M.
    Kovacic, Jason C.
    Basnet, Sandeep
    Makoto, Amaki
    Chaudhry, Farooq A.
    Mini, Annapoorna S.
    Sharma, Samin K.
    Sengupta, Partho P.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2016, 9 (02) : 213 - 215
  • [36] 3-Dimensional Aortic Annular Assessment by Multidetector Computed Tomography Predicts Moderate or Severe Paravalvular Regurgitation After Transcatheter Aortic Valve Replacement A Multicenter Retrospective Analysis
    Willson, Alexander B.
    Webb, John G.
    LaBounty, Troy M.
    Achenbach, Stephan
    Moss, Robert
    Wheeler, Miriam
    Thompson, Christopher
    Min, James K.
    Gurvitch, Ronen
    Norgaard, Bjarne L.
    Hague, Cameron J.
    Toggweiler, Stefan
    Binder, Ronald
    Freeman, Melanie
    Poulter, Rohan
    Poulsen, Steen
    Wood, David A.
    Leipsic, Jonathon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) : 1287 - 1294
  • [37] Aortic Root Geometry in Patients with Aortic Stenosis Assessed by Real-Time Three-Dimensional Transesophageal Echocardiography
    Wu, Victor Chien-Chia
    Kaku, Kyoko
    Takeuchi, Masaaki
    Otani, Kyoko
    Yoshitani, Hidetoshi
    Tamura, Masahito
    Abe, Haruhiko
    Lin, Fen-Chiung
    Otsuji, Yutaka
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (01) : 32 - 41
  • [38] Incidence and Severity of Paravalvular Aortic Regurgitation With Multidetector Computed Tomography Nominal Area Oversizing or Undersizing After Transcatheter Heart Valve Replacement With the Sapien 3 A Comparison With the Sapien XT
    Yang, Tae-Hyun
    Webb, John G.
    Blanke, Philipp
    Dvir, Danny
    Hansson, Nicolaj C.
    Norgaard, Bjarne L.
    Thompson, Christopher R.
    Thomas, Martyn
    Wendler, Olaf
    Vahanian, Alec
    Himbert, Dominique
    Kodali, Susheel K.
    Hahn, Rebecca T.
    Thourani, Vinod H.
    Schymik, Gerhard
    Precious, Bruce
    Berger, Adam
    Wood, David A.
    Pibarot, Philippe
    Rodes-Cabau, Josep
    Jaber, Wael A.
    Leon, Martin B.
    Walther, Thomas
    Leipsic, Jonathon
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (03) : 462 - 471