Three-Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta-Analysis

被引:28
作者
Rong, Lisa Q. [1 ]
Hameed, Irbaz [2 ]
Salemi, Arash [2 ]
Rahouma, Mohamed [2 ]
Khan, Faiza M. [2 ]
Wijeysundera, Harindra C. [3 ]
Angiolillo, Dominick J. [4 ]
Shore-Lesserson, Linda [5 ]
Biondi-Zoccai, Giuseppe [6 ,7 ]
Girardi, Leonard N. [2 ]
Fremes, Stephen E. [3 ]
Gaudino, Mario [2 ]
机构
[1] Weill Cornell Med, Dept Anesthesiol, 525 East 68th St,M324, New York, NY 10065 USA
[2] Weill Cornell Med, Dept Cardiothorac Surg, New York, NY USA
[3] Univ Toronto, Schulich Heart Ctr, Sunnybrook Hlth Sci, Toronto, ON, Canada
[4] Univ Florida, Coll Med, Div Cardiol, Jacksonville, FL USA
[5] North Shore Univ Hosp, Dept Anesthesiol, Manhasset, NY USA
[6] Sapienza Univ Rome, Dept Medicosurg Sci & Biotechnol, Latina, Italy
[7] Mediterranea Cardioctr, Naples, Italy
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2019年 / 8卷 / 19期
关键词
multidetector row computed tomography; transesophageal echocardiography; transfemoral aortic valve implantation; MULTIDETECTOR COMPUTED-TOMOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ANNULUS; ACCURACY; ROOT; REGURGITATION; STENOSIS; CT; IMPLANTATION; SOFTWARE;
D O I
10.1161/JAHA.119.013463
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Transcatheter aortic valve replacement (TAVR) is the standard of care for many patients with severe symptomatic aortic stenosis and relies on accurate sizing of the aortic annulus. It has been suggested that 3-dimensional transesophageal echocardiography (3D TEE) may be used instead of multidetector computed tomography (MDCT) for TAVR planning. This systematic review and meta-analysis compared 3D TEE and MDCT for pre-TAVR measurements. Methods and Results-A systematic literature search was performed. The primary outcome was the correlation coefficient between 3D TEE- and MDCT-measured annular area. Secondary outcomes were correlation coefficients for mean annular diameter, annular perimeter, and left ventricular outflow tract area; interobserver and intraobserver agreements; mean differences between 3D TEE and MDCT measurements; and pooled sensitivities, specificities, and receiver operating characteristic area under curve values of 3D TEE and MDCT for discriminating post-TAVR paravalvular aortic regurgitation. A random effects model was used. Meta-regression and leave-one-out analysis for the primary outcome were performed. Nineteen studies with a total of 1599 patients were included. Correlations between 3D TEE and MDCT annular area, annular perimeter, annular diameter, and left ventricular outflow tract area measurements were strong (0.86 [95% CI, 0.80-0.90]; 0.89 [CI, 0.82-0.93]; 0.80 [CI, 0.70-0.87]; and 0.78 [CI, 0.61-0.88], respectively). Mean differences between 3D TEE and MDCT between measurements were small and nonsignificant. Interobserver and intraobserver agreement and discriminatory abilities for paravalvular aortic regurgitation were good for both 3D TEE and MDCT. Conclusions-For pre-TAVR planning, 3D TEE is comparable to MDCT. In patients with renal dysfunction, 3D TEE may be potentially advantageous for TAVR measurements because of the lack of contrast exposure.
引用
收藏
页数:34
相关论文
共 38 条
  • [1] High statistical heterogeneity is more frequent in meta-analysis of continuous than binary outcomes
    Alba, Ana C.
    Alexander, Paul E.
    Chang, Joanne
    Maclsaac, John
    DeFry, Samantha
    Guyatt, Gordon H.
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2016, 70 : 129 - 135
  • [2] Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation
    Altiok, Ertunc
    Koos, Ralf
    Schroeder, Joerg
    Brehmer, Kathrin
    Hamada, Sandra
    Becker, Michael
    Mahnken, Andreas H.
    Almalla, Mohammad
    Dohmen, Guido
    Autschbach, Ruediger
    Marx, Nikolaus
    Hoffmann, Rainer
    [J]. HEART, 2011, 97 (19) : 1578 - 1584
  • [3] [Anonymous], METAANALYSIS R
  • [4] [Anonymous], MET CORR
  • [5] [Anonymous], 2011, BMJ, V343, pd5928, DOI [DOI 10.1136/BMJ.D5928, 10.1136/bmj.d5928]
  • [6] ACC/AATS/AHA/ASE/EACTS/HVS/SCA/SCAI/SCCT/SCMR/STS 2017 Appropriate Use Criteria for the Treatment of Patients With Severe Aortic Stenosis
    Bonow, Robert O.
    Brown, Alan S.
    Gillam, Linda D.
    Kapadia, Samir R.
    Kavinsky, Clifford J.
    Lindman, Brian R.
    Mack, Michael J.
    Thourani, Vinod H.
    Dehmer, Gregory J.
    Bonow, Robert O.
    Lindman, Brian R.
    Beaver, Thomas M.
    Bradley, Steven M.
    Carabello, Blase A.
    Desai, Milind Y.
    George, Isaac
    Green, Philip
    Holmes, David R., Jr.
    Johnston, Douglas
    Leipsic, Jonathon
    Mick, Stephanie L.
    Passeri, Jonathan J.
    Piana, Robert N.
    Reichek, Nathaniel
    Ruiz, Carlos E.
    Taub, Cynthia C.
    Thomas, James D.
    Turi, Zoltan G.
    Doherty, John U.
    Dehmer, Gregory J.
    Bailey, Steven R.
    Bhave, Nicole M.
    Brown, Alan S.
    Daugherty, Stacie L.
    Dean, Larry S.
    Desai, Milind Y.
    Duvernoy, Claire S.
    Gillam, Linda D.
    Hendel, Robert C.
    Kramer, Christopher M.
    Lindsay, Bruce D.
    Manning, Warren J.
    Mehrotra, Praveen
    Patel, Manesh R.
    Sachdeva, Ritu
    Wann, L. Samuel
    Winchester, David E.
    Allen, Joseph M.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2018, 31 (02) : 117 - 147
  • [7] METAANALYSIS IN CLINICAL-TRIALS
    DERSIMONIAN, R
    LAIRD, N
    [J]. CONTROLLED CLINICAL TRIALS, 1986, 7 (03): : 177 - 188
  • [8] Three-dimensional transesophageal echocardiography is an attractive alternative to cardiac multi-detector computed tomography for aortic annular sizing: Systematic review and meta-analysis
    Elkaryoni, Ahmed
    Nanda, Navin C.
    Baweja, Paramdeep
    Arisha, Mohammed J.
    Zamir, Harris
    Elgebaly, Ahmed
    Altibi, Ahmed M. A.
    Sharma, Rishi
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (10): : 1626 - 1634
  • [9] Accuracy and reproducibility of novel echocardiographic three-dimensional automated software for the assessment of the aortic root in candidates for thanscatheter aortic valve replacement
    Garcia-Martin, Ana
    Lazaro-Rivera, Carla
    Fernandez-Golfin, Covadonga
    Salido-Tahoces, Luisa
    Moya-Mur, Jose-Luis
    Jimenez-Nacher, Jose-Julio
    Casas-Rojo, Eduardo
    Aquila, Iolanda
    Gonzalez-Gomez, Ariana
    Hernandez-Antolin, Rosana
    Luis Zamorano, Jose
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (07) : 772 - 778
  • [10] Three-Dimensional Echocardiography in Paravalvular Aortic Regurgitation Assessment after Transcatheter Aortic Valve Implantation
    Goncalves, Alexandra
    Almeria, Carlos
    Marcos-Alberca, Pedro
    Feltes, Gisela
    Hernandez-Antolin, Rosana
    Rodriguez, Enrique
    Silva Cardoso, Jose C.
    Macaya, Carlos
    Luis Zamorano, Jose
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 47 - 55