Study of near infrared technology for intracranial hematoma detection

被引:49
作者
Zhang, Q [1 ]
Ma, HY [1 ]
Nioka, S [1 ]
Chance, B [1 ]
机构
[1] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
关键词
intracranial hematomas; near infrared spectroscopy; continuous wave;
D O I
10.1117/1.429988
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although intracranial hematoma detection only requires the continuous wave technique of near infrared spectroscopy (NIRS), previous studies have shown that there are still some problems in obtaining very accurate, reliable hematoma detection. Several of the most important limitations of NIR technology for hematoma detection such as the dynamic range of detection, hair absorption, optical contact, layered structure of the head, and depth of detection are reported in this article, A pulsed light source of variable intensity was designed and studied in order to overcome hair absorption and to increase the dynamic range and depth of detection. An adaptive elastic optical probe was made to improve the optical contact and decrease contact noise. A new microcontroller operated portable hematoma detector was developed. Due to the layered structure of the human head, simulation on a layered medium was analyzed experimentally. Model inhomogeneity tests and animal hematoma tests showed the effectiveness of the improved hematoma detector for intracranial hematoma detection, (C) 2000 Society of Photo-Optical Instrumentation Engineers. [S1083-3668(00)01302-2].
引用
收藏
页码:206 / 213
页数:8
相关论文
共 23 条
  • [1] Estimation of the optical properties of two-layer tissue simulating phantoms from spatially resolved frequency-domain reflectance
    Alexandrakis, G
    Weersink, RA
    Bruulsema, JT
    Patterson, MS
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 155 - 163
  • [2] American National Standards Institute, 1993, Z1361 ANSI
  • [3] Boas D. A., 1996, THESIS U PENNSYLVANI
  • [4] Precision localization of hidden absorbers in body tissues with phased-array optical systems
    Chance, B
    Kang, KA
    He, LB
    Liu, HL
    Zhou, SM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (12) : 4324 - 4332
  • [5] Optical investigations of physiology: A study of intrinsic and extrinsic biomedical contrast
    Chance, B
    Luo, QM
    Nioka, S
    Alsop, DC
    Detre, JA
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1997, 352 (1354) : 707 - 716
  • [6] CHANCE B, 1991, ANNU REV BIOPHYS BIO, V20, P1
  • [7] Phase measurement of light absorption and scatter in human tissue
    Chance, B
    Cope, M
    Gratton, E
    Ramanujam, N
    Tromberg, B
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (10) : 3457 - 3481
  • [8] EFFECTS OF SOLUTES ON OPTICAL-PROPERTIES OF BIOLOGICAL-MATERIALS - MODELS, CELLS, AND TISSUES
    CHANCE, B
    LIU, HL
    KITAI, T
    ZHANG, YT
    [J]. ANALYTICAL BIOCHEMISTRY, 1995, 227 (02) : 351 - 362
  • [9] COGNITION-ACTIVATED LOW-FREQUENCY MODULATION OF LIGHT-ABSORPTION IN HUMAN BRAIN
    CHANCE, B
    ZHUANG, Z
    UNAH, C
    ALTER, C
    LIPTON, L
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (08) : 3770 - 3774
  • [10] THE RELATIONSHIP OF SURFACE REFLECTANCE MEASUREMENTS TO OPTICAL-PROPERTIES OF LAYERED BIOLOGICAL MEDIA
    CUI, WJ
    OSTRANDER, LE
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (02) : 194 - 201