Effect of phase transformation on ductility of additively manufactured Co-28Cr-6Mo alloy: An in situ synchrotron X-ray diffraction study during mechanical testing

被引:26
作者
Antunes, L. H. M. [1 ]
Hoyos, J. J. [2 ]
Fonseca, E. B. [1 ]
Beres, M. [3 ,4 ]
da Silva Farina, P. F. [1 ]
Lopes, E. S. N. [1 ]
Jardini, A. L. [3 ]
Maciel Filho, R. [3 ]
机构
[1] Univ Estadual Campinas, Sch Mech Engn, Rua Mendeleyev 200, BR-13083860 Campinas, SP, Brazil
[2] State Univ Ponta Grosso, Mat Engn Dept, Av Gen Carlos Cavalcanti 4748, BR-84030900 Ponta Grossa, Brazil
[3] Univ Estadual Campinas, Fac Chem Engn, Natl Inst Biofabricat, Av Albert Einstein 500, BR-13083852 Campinas, SP, Brazil
[4] Univ Fed Ceara, Dept Met & Mat Engn, Av Humberto Monte, BR-60445554 Fortaleza, CE, Brazil
来源
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING | 2019年 / 764卷
基金
巴西圣保罗研究基金会;
关键词
CoCrMo alloy; Selective laser melting; Strain induced martensitic transformation; Ductility; In-situ X-ray diffraction; Characterization; CR-MO ALLOY; INDUCED MARTENSITIC-TRANSFORMATION; DIRECT METAL LASER; EPSILON-MARTENSITE; TENSILE PROPERTIES; FATIGUE-STRENGTH; GRAIN-SIZE; MICROSTRUCTURES; TEMPERATURE; BEHAVIOR;
D O I
10.1016/j.msea.2019.138262
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The influence of strain-induced martensitic transformation on the mechanical properties of a Co-28Cr-6Mo alloy produced using the direct metal laser sintering additive manufacturing technique was analyzed. Both the as-built and solution heat-treated (ST) specimens were subjected to conventional tensile tests. Furthermore, X-ray diffraction spectra were simultaneously acquired using a synchrotron light source. In addition, electron backscatter diffraction analysis was performed on the specimens before and after tensile testing. Both techniques revealed the occurrence of the strain-induced gamma-face-centered cubic -> epsilon-hexagonal close-packed phase transformation. The higher microstrain and preferential grain orientation of the as-built specimen favored the onset of the phase transformation. Moreover, the ductility of the ST specimen was significantly higher than that of the as-built specimen. This behavior was attributed to the isotropic properties of the randomly-oriented and equiaxed grains, increase in resistance to necking, and reduction in internal stresses caused by the solution heat treatment.
引用
收藏
页数:8
相关论文
共 44 条
[1]  
[Anonymous], 1978, ELEMENTS XRAY DIFFRA
[2]  
ASTM, 2010, B96217 ASTM INT, P1, DOI 10.1520/B0822-10
[3]  
ASTM-American Society for Testing and Materials, 2014, F89511 ASTM, P1
[4]   Mechanical and phase transformation behaviour of biomedical Co-Cr-Mo alloy fabricated by direct metal laser sintering [J].
Beres, M. ;
Silva, C. C. ;
Sarvezuk, P. W. C. ;
Wu, L. ;
Antunes, L. H. M. ;
Jardini, A. L. ;
Feitosa, A. L. M. ;
Zilkova, J. ;
de Abreu, H. F. G. ;
Filho, R. M. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2018, 714 :36-42
[5]  
Bhadeshia H. K. D. H., 2006, STEELS MICROSTRUCTUR, P17, DOI [10.1016/B978-075068084-4/50004-2, DOI 10.1016/B978-075068084-4/50004-2]
[6]   An instrument for in situ time-resolved X-ray imaging and diffraction of laser powder bed fusion additive manufacturing processes [J].
Calta, Nicholas P. ;
Wang, Jenny ;
Kiss, Andrew M. ;
Martin, Aiden A. ;
Depond, Philip J. ;
Guss, Gabriel M. ;
Thampy, Vivek ;
Fong, Anthony Y. ;
Weker, Johanna Nelson ;
Stone, Kevin H. ;
Tassone, Christopher J. ;
Kramer, Matthew J. ;
Toney, Michael F. ;
Van Buuren, Anthony ;
Matthews, Manyalibo J. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (05)
[7]   A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty [J].
Cawley, J ;
Metcalf, JEP ;
Jones, AH ;
Band, TJ ;
Skupien, DS .
WEAR, 2003, 255 :999-1006
[8]   Microstructural Control of Additively Manufactured Metallic Materials [J].
Collins, P. C. ;
Brice, D. A. ;
Samimi, P. ;
Ghamarian, I. ;
Fraser, H. L. .
ANNUAL REVIEW OF MATERIALS RESEARCH, VOL 46, 2016, 46 :63-91
[9]   Material and structural tensile properties of the human medial patello-femoral ligament [J].
Criscenti, G. ;
De Maria, C. ;
Sebastiani, E. ;
Tei, M. ;
Placella, G. ;
Speziali, A. ;
Vozzi, G. ;
Cerulli, G. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 54 :141-148
[10]   Functionalization of Ti6Al4V scaffolds produced by direct metal laser for biomedical applications [J].
de Damborenea, Juan J. ;
Larosa, Maria Aparecida ;
Angeles Arenas, Maria ;
Manuel Hernandez-Lopez, Juan ;
Jardini, Andre Luiz ;
Ierardi, Maria Clara F. ;
Zavaglia, Cecilia A. C. ;
Maciel Filho, Rubens ;
Conde, Ana .
MATERIALS & DESIGN, 2015, 83 :6-13