Leveraging Device-Arterial Coupling to Determine Cardiac and Vascular State

被引:7
作者
Chang, Brian Y. [1 ]
Keller, Steven P. [1 ,2 ]
Edelman, Elazer R. [1 ,3 ]
机构
[1] MIT, Inst Med Engn & Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Harvard Med Sch, Brigham & Womens Hosp, Div Pulm & Crit Care Med, Boston, MA 02115 USA
[3] Harvard Med Sch, Brigham & Womens Hosp, Div Cardiovasc Dis, Boston, MA 02115 USA
关键词
Cardiac output; vascular resistance; mechanical circulatory support; cardiogenic shock; vascular coupling; MECHANICAL CIRCULATORY SUPPORT; ACUTE MYOCARDIAL-INFARCTION; CARDIOGENIC-SHOCK; FLUID RESPONSIVENESS; RESPIRATORY CHANGES; HEART; PUMP; MANAGEMENT; KNOWLEDGE; PRESSURE;
D O I
10.1109/TBME.2019.2895752
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Limitations in available diagnostic metrics restrict the efficacy of managing therapies for cardiogenic shock. In current clinical practice, cardiovascular state is inferred through measurement of pulmonary capillary wedge pressure and reliance on linear approximations between pressure and flow to estimate peripheral vascular resistance. Mechanical circulatory support devices residing within the left ventricle and aorta provide an opportunity for both determining cardiac and vascular state and offering therapeutic benefit. We leverage the controllable mode of operation and transvalvular position of an indwelling percutaneous ventricular assist device to assess vascular and, in turn, cardiac state through the effects of device-arterial coupling across different levels of device support. Methods: Vascular state is determined by measuring changes in the pressure waveforms induced through intentional variation in the device generated blood flow. We evaluate this impact by applying a lumped parameter model to quantify state-specific vascular resistance and compliance and calculate beat-to-beat stroke volume and cardiac output in both animal models and retrospective patient data without external calibration. Results: Vascular state was accurately predicted in patients and animals in both baseline and experimental conditions. In the animal, stroke volume was predicted within a total root mean square error of 3.71 mL (n = 482). Conclusion: We demonstrate that device-arterial coupling is a powerful tool for evaluating patient and state specific parameters of cardiovascular function. Significance: These insights may yield improved clinical care and support the development of next generation mechanical circulatory support devices that determine and operate in tandem with the supported organ.
引用
收藏
页码:2800 / 2808
页数:9
相关论文
共 45 条
[31]   Management of refractory cardiogenic shock [J].
Reyentovich, Alex ;
Barghash, Maya H. ;
Hochman, Judith S. .
NATURE REVIEWS CARDIOLOGY, 2016, 13 (08) :481-492
[32]   2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care [J].
Rihal, Charanjit S. ;
Naidu, Srihari S. ;
Givertz, Michael M. ;
Szeto, Wilson Y. ;
Burke, James A. ;
Kapur, Navin K. ;
Kern, Morton ;
Garratt, Kirk N. ;
Goldstein, James A. ;
Dimas, Vivian ;
Tu, Thomas .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (19) :E7-E26
[33]   Epidemiology of Heart Failure [J].
Roger, Veronique L. .
CIRCULATION RESEARCH, 2013, 113 (06) :646-659
[34]  
Ruschen Daniel, 2015, IFAC - Papers Online, V48, P569, DOI 10.1016/j.ifacol.2015.10.202
[35]   Options for temporary mechanical circulatory support [J].
Saffarzadeh, Areo ;
Bonde, Pramod .
JOURNAL OF THORACIC DISEASE, 2015, 7 (12) :2102-2111
[36]   TRANSLATION OF FRANK,OTTO PAPER THE BASIC SHAPE OF THE ARTERIAL PULSE - 1ST TREATISE - MATHEMATICAL-ANALYSIS - TRANSLATORS INTRODUCTION [J].
SAGAWA, K ;
LIE, RK ;
SCHAEFER, J .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1990, 22 (03) :253-254
[37]   The heart-pump interaction: Effects of a microaxial blood pump [J].
Stolinski, J ;
Rosenbaum, C ;
Flameng, W ;
Meyns, B .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (11) :1082-1088
[38]  
SURYANTO N, 2017, JAMA CARDIOL, P1
[39]   CATHETERIZATION OF HEART IN MAN WITH USE OF FLOW-DIRECTED BALLOON-TIPPED CATHETER [J].
SWAN, HJC ;
GANZ, W ;
FORRESTER, J ;
MARCUS, H ;
DIAMOND, G ;
CHONETTE, D .
NEW ENGLAND JOURNAL OF MEDICINE, 1970, 283 (09) :447-+
[40]   Improved survival after acute myocardial infarction complicated by cardiogenic shock with circulatory support and transplantation: Comparing aggressive intervention with conservative treatment [J].
Tayara, Wakkas ;
Starling, Randall C. ;
Yamani, Mohamad H. ;
Wazni, Oussama ;
Jubran, Fuad ;
Smedira, Nicholas .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (05) :504-509