Design and experimental evaluation of an automated catheter operating system

被引:15
|
作者
Norouzi-Ghazbi, Somayeh [1 ]
Mehrkish, Ali [2 ]
Abdulhafiz, Ibrahim [1 ]
Abbasi-Hashemi, Taha [1 ]
Mahdi, Anas [1 ]
Janabi-Sharifi, Farrokh [3 ]
机构
[1] Ryerson Univ, Biomed Engn, Toronto, ON, Canada
[2] Ryerson Univ, Mech & Ind Engn, Toronto, ON, Canada
[3] Ryerson Univ, Fac Biomed Engn, Toronto, ON, Canada
关键词
catheter-based interventions; continuum robot; design; medical robots; robot-assisted catheterization systems; CONTINUUM ROBOTS; ABLATION;
D O I
10.1111/aor.13870
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Manual catheter-based interventions (CBIs) suffer from exposure of the interventionalists to X-ray, and dependence of their performance on the expertise and fatigue level of the interventionalists. Robot-assisted catheterization systems (RACS) have been introduced in recent years to improve the efficiency of CBIs; however, using them is still associated with some difficulties such as set-up dependency to a specific type of intervention instrument, not being portable, and offering limited options of operation modes. The objective of this research is to develop a new RACS to address these shortcomings. We propose Althea II as an improvement for our previously introduced RACS, Althea I. Althea II is designed for both research purposes and clinical applications including catheter-based cardiovascular interventions. Althea II benefits from a novel structural design leading to a significantly reduced weight and making the device inclusive for a broader range of intervention instruments. Also, a tip detection algorithm is developed and integrated into the graphical user interface (GUI) to enable image-based navigation, and accordingly, fully automatic navigation. Althea II has improved the outcome of catheter-based interventions by increased accuracy and precision of the intervention. The system can navigate the catheter tip to a designated target with an accuracy higher than 90% in both velocity and positioning mode. The device is associated with an upgraded GUI equipped with a strong tip detection algorithm with an accuracy of 0.05 mm. Moreover, Althea II gains from a quicker assembly time (20 minutes, which equals five times faster). The independency from specific catheters, several modes of function, an imaged-based feedback control, portability, and a remote function should allow operation even from beginners and reduce X-ray exposure. The preliminary research studies verified the accuracy and repeatability of Althea II, demonstrated the feasibility and applicability of using the set-up in multiple applications, and highlighted the improved set-up capabilities over the currently available RACS.
引用
收藏
页码:E171 / E186
页数:16
相关论文
共 50 条
  • [31] Numerical simulation and experimental analysis of an LCPV/T system under real operating conditions
    Chen Haiping
    Liu Haowen
    Zhang Heng
    Liang Kai
    Guo Xinxin
    Yang Boran
    JOURNAL OF CLEANER PRODUCTION, 2019, 209 : 903 - 915
  • [32] Design and experimental study of a mower conditioner drive system
    Luo Yalan
    Zhao Chunhua
    MATERIALS SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2014, 488-489 : 1169 - 1172
  • [33] Evaluation of the safety and effectiveness of the CryoMedix cryoablation catheter system for the treatment of atrial flutter and fibrillation
    Feld, Gregory K.
    Yao, Biguang
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (01) : 37 - 44
  • [34] AUTOMATED FIXTURE DESIGN
    WILLY, A
    SADLER, JP
    SCHRAFT, RD
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 1995, 10 (01) : 27 - 35
  • [35] Influence of the irrigation flow pattern and catheter tip design on the lesion formation: an ex vivo experimental model
    Kuroda, Maiko
    Takeo, Ayaka
    Kobayashi, Hiroki
    Kuji, Rei
    Mori, Hitoshi
    Tsutsui, Kenta
    Fukunaga, Masato
    Nagashima, Michio
    Korai, Kengo
    Ando, Kenji
    Hiroshima, Kenichi
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (03) : 589 - 597
  • [36] Design and Operating for the Logistics Systems
    Wang, Yan-Ling
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 3101 - 3105
  • [37] Influence of design and operating conditions on the system performance of a two-stage adsorption chiller
    Alam, KCA
    Saha, BB
    Akisawa, A
    Kashiwagi, T
    CHEMICAL ENGINEERING COMMUNICATIONS, 2004, 191 (07) : 981 - 997
  • [39] Bayesian Optimization for Design of Multi-Actuator Soft Catheter Robots
    Ghoreishi, Seyede Fatemeh
    Sochol, Ryan D.
    Gandhi, Dheeraj
    Krieger, Axel
    Fuge, Mark
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2021, 3 (03): : 725 - 737
  • [40] Evaluation of a novel coupling system for various load conditions under different operating strategies
    Kang, Shushuo
    Li, Hongqiang
    Liu, Lifang
    Zeng, Rong
    Zhang, Guoqiang
    ENERGY CONVERSION AND MANAGEMENT, 2016, 109 : 40 - 50