Design and experimental evaluation of an automated catheter operating system

被引:15
|
作者
Norouzi-Ghazbi, Somayeh [1 ]
Mehrkish, Ali [2 ]
Abdulhafiz, Ibrahim [1 ]
Abbasi-Hashemi, Taha [1 ]
Mahdi, Anas [1 ]
Janabi-Sharifi, Farrokh [3 ]
机构
[1] Ryerson Univ, Biomed Engn, Toronto, ON, Canada
[2] Ryerson Univ, Mech & Ind Engn, Toronto, ON, Canada
[3] Ryerson Univ, Fac Biomed Engn, Toronto, ON, Canada
关键词
catheter-based interventions; continuum robot; design; medical robots; robot-assisted catheterization systems; CONTINUUM ROBOTS; ABLATION;
D O I
10.1111/aor.13870
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Manual catheter-based interventions (CBIs) suffer from exposure of the interventionalists to X-ray, and dependence of their performance on the expertise and fatigue level of the interventionalists. Robot-assisted catheterization systems (RACS) have been introduced in recent years to improve the efficiency of CBIs; however, using them is still associated with some difficulties such as set-up dependency to a specific type of intervention instrument, not being portable, and offering limited options of operation modes. The objective of this research is to develop a new RACS to address these shortcomings. We propose Althea II as an improvement for our previously introduced RACS, Althea I. Althea II is designed for both research purposes and clinical applications including catheter-based cardiovascular interventions. Althea II benefits from a novel structural design leading to a significantly reduced weight and making the device inclusive for a broader range of intervention instruments. Also, a tip detection algorithm is developed and integrated into the graphical user interface (GUI) to enable image-based navigation, and accordingly, fully automatic navigation. Althea II has improved the outcome of catheter-based interventions by increased accuracy and precision of the intervention. The system can navigate the catheter tip to a designated target with an accuracy higher than 90% in both velocity and positioning mode. The device is associated with an upgraded GUI equipped with a strong tip detection algorithm with an accuracy of 0.05 mm. Moreover, Althea II gains from a quicker assembly time (20 minutes, which equals five times faster). The independency from specific catheters, several modes of function, an imaged-based feedback control, portability, and a remote function should allow operation even from beginners and reduce X-ray exposure. The preliminary research studies verified the accuracy and repeatability of Althea II, demonstrated the feasibility and applicability of using the set-up in multiple applications, and highlighted the improved set-up capabilities over the currently available RACS.
引用
收藏
页码:E171 / E186
页数:16
相关论文
共 50 条
  • [1] Performance evaluation of a robot-assisted catheter operating system with haptic feedback
    Song, Yu
    Guo, Shuxiang
    Yin, Xuanchun
    Zhang, Linshuai
    Hirata, Hideyuki
    Ishihara, Hidenori
    Tamiya, Takashi
    BIOMEDICAL MICRODEVICES, 2018, 20 (02)
  • [2] Design, development and evaluation of a compact telerobotic catheter navigation system
    Tavallaei, Mohammad Ali
    Gelman, Daniel
    Lavdas, Michael Konstantine
    Skanes, Allan C.
    Jones, Douglas L.
    Bax, Jeffrey S.
    Drangova, Maria
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (03) : 442 - 452
  • [3] Internet-based Robotic Catheter Surgery System -System Design and Performance Evaluation
    Xiao, Nan
    Guo, Shuxiang
    Gao, Baofeng
    Ma, Xu
    Tamiya, Takashi
    Kawanishi, Masahiko
    2012 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS (ICAL), 2012, : 634 - 640
  • [4] A Haptic Catheter Operating System Using Magnetorheological Fluids
    Yin, Xuanchun
    Guo, Shuxiang
    Yue, Chunfeng
    Wang, Yu
    2014 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2014), 2014, : 1631 - 1636
  • [5] Design and evaluation of safety operation VR training system for robotic catheter surgery
    Wang, Yu
    Guo, Shuxiang
    Li, Yaxin
    Tamiya, Takashi
    Song, Yu
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (01) : 25 - 35
  • [6] Performance evaluation of a strain-gauge force sensor for a haptic robot-assisted catheter operating system
    Zhang, Linshuai
    Guo, Shuxiang
    Yu, Huadong
    Song, Yu
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (10): : 5041 - 5050
  • [7] An automated system for product specification and design
    Wei, CC
    Liu, PH
    Chen, CB
    ASSEMBLY AUTOMATION, 2000, 20 (03) : 225 - 232
  • [8] Magnetorheological Fluids Actuated Haptic-Based Teleoperated Catheter Operating System
    Yin, Xuanchun
    Guo, Shuxiang
    Song, Yu
    MICROMACHINES, 2018, 9 (09)
  • [9] The Beam Theory-based Collision Force Detection of the Catheter Operating System
    Zhangchaonan
    Guo, Shuxiang
    Gao, Baofeng
    Jia, Feiyu
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 701 - 706
  • [10] Novel Design of Master Manipulator for Robotic Catheter System
    Moon, Youngjin
    Hu, Zhenkai
    Won, Jongseok
    Park, Sanghoon
    Lee, Hoyul
    You, Hyeonseok
    Nam, Gi-Byoung
    Choi, Jaesoon
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2018, 16 (06) : 2924 - 2934