Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction

被引:41
|
作者
Inoue, Tadahisa [1 ,2 ]
Naitoh, Itaru [3 ]
Okumura, Fumihiro [1 ]
Ozeki, Takanori [1 ]
Anbe, Kaiki [1 ]
Iwasaki, Hiroyasu [1 ]
Nishie, Hirotada [1 ]
Mizushima, Takashi [1 ]
Sano, Hitoshi [1 ]
Nakazawa, Takahiro [3 ]
Yoneda, Masashi [2 ]
Joh, Takashi [3 ]
机构
[1] Gifu Prefectural Tajimi Hosp, Dept Gastroenterol, Tajimi, Japan
[2] Aichi Med Univ, Sch Med, Dept Gastroenterol, Nagakute, Aichi, Japan
[3] Nagoya City Univ, Grad Sch Med Sci, Dept Gastroenterol & Metab, Nagoya, Aichi, Japan
关键词
malignant hilar biliary obstruction; recurrent biliary obstruction; reintervention; revisionary stent; self-expandable metallic stent; SIDE-BY-SIDE; DEPLOYMENT; DRAINAGE; CELL;
D O I
10.1111/den.12657
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Methods: Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Results: Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Conclusion: Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [41] Biopsy sampling during self-expandable metallic stent placement in acute malignant colorectal obstruction: a narrative review
    Bennedsgaard, Sigrid Skov
    Iversen, Lene Hjerrild
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2021, 19 (01)
  • [42] Uncovered Self-Expandable Metallic Stent with an Ultra-Thin Delivery Sheath in Unresectable Malignant Hilar Biliary Obstruction: A Multicenter Prospective Observational Study
    Takeshita, Kotaro
    Hijioka, Susumu
    Ikezawa, Kenji
    Ogura, Takeshi
    Kuwatani, Masaki
    Fujimori, Nao
    Doi, Shinpei
    Endo, Masato
    Matsubara, Saburo
    Yamada, Reiko
    Mashima, Hirosato
    Kataoka, Mikinori
    Takada, Ryoji
    Okuda, Atsushi
    Ohno, Akihisa
    Katsukura, Nobuhiro
    Suzuki, Hirosumi
    Tanaka, Takamitsu
    Sekine, Masanari
    Kitamura, Hidetoshi
    Okusaka, Takuji
    DIGESTIVE DISEASES AND SCIENCES, 2025, : 1560 - 1572
  • [43] Biliary self-expandable metallic stent combined with iodine-125 seeds in the treatment of malignant biliary obstruction (Bismuth type I or II)
    Chai, Jie
    Liu, Kaicai
    Xu, Beibei
    Wang, Lijun
    Yu, Huafeng
    Lv, Weifu
    Lu, Dong
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (10): : 7729 - 7737
  • [44] Evaluating optimal bilateral biliary stenting in endoscopic reintervention after initial plastic stent dysfunction for unresectable malignant hilar biliary obstruction: Retrospective cross-sectional study
    Okuno, Mitsuru
    Iwata, Keisuke
    Iwashita, Takuji
    Mukai, Tsuyoshi
    Shimojo, Kota
    Ohashi, Yosuke
    Iwasa, Yuhei
    Senju, Akihiko
    Iwata, Shota
    Tezuka, Ryuichi
    Ichikawa, Hironao
    Mita, Naoki
    Uemura, Shinya
    Yoshida, Kensaku
    Maruta, Akinori
    Tomita, Eiichi
    Yasuda, Ichiro
    Shimizu, Masahito
    DIGESTIVE ENDOSCOPY, 2024, 36 (10) : 1153 - 1163
  • [45] Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study
    Jiao, Dechao
    Huang, Kai
    Zhu, Ming
    Wu, Gang
    Ren, Jianzhuang
    Wang, Yanli
    Han, Xinwei
    DIGESTIVE DISEASES AND SCIENCES, 2017, 62 (01) : 253 - 263
  • [46] Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large can type stent
    Park, Jin Myung
    Lee, Sang Hyub
    Chung, Kwang Hyun
    Jang, Dong Kee
    Ryu, Ji Kon
    Kim, Yong-Tae
    Lee, Jae Min
    Paik, Woo Hyun
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2016, 15 (06) : 633 - 639
  • [47] Simultaneous Versus Sequential Side-by-Side Bilateral Metal Stent Placement for Malignant Hilar Biliary Obstructions
    Inoue, Tadahisa
    Ishii, Norimitsu
    Kobayashi, Yuji
    Kitano, Rena
    Sakamoto, Kazumasa
    Ohashi, Tomohiko
    Nakade, Yukiomi
    Sumida, Yoshio
    Ito, Kiyoaki
    Nakao, Haruhisa
    Yoneda, Masashi
    DIGESTIVE DISEASES AND SCIENCES, 2017, 62 (09) : 2542 - 2549
  • [48] Feasibility of the placement of a novel 6-mm diameter threaded fully covered self-expandable metal stent for malignant hilar biliary obstructions (with videos)
    Inoue, Tadahisa
    Okumura, Fumihiro
    Naitoh, Itaru
    Fukusada, Shigeki
    Kachi, Kenta
    Ozeki, Takanori
    Anbe, Kaiki
    Iwasaki, Hiroyasu
    Mizushima, Takashi
    Kobayashi, Yuji
    Ishii, Norimitsu
    Ito, Kiyoaki
    Kondo, Hiromu
    Hayashi, Kazuki
    Yoneda, Masashi
    Sano, Hitoshi
    GASTROINTESTINAL ENDOSCOPY, 2016, 84 (02) : 352 - 357
  • [49] Endoscopic ultrasound (EUS)-guided transhepatic anterograde self-expandable metal stent (SEMS) placement across malignant biliary obstruction
    Nguyen-Tang, T.
    Binmoeller, K. F.
    Sanchez-Yague, A.
    Shah, J. N.
    ENDOSCOPY, 2010, 42 (03) : 232 - 236
  • [50] Percutaneous stent placement for malignant hilar biliary obstruction: side-by-side versus stent-in-stent technique
    Zhou, Wei-Zhong
    Liu, Sheng
    Yang, Zheng-Qiang
    Xian, Yu-Tao
    Xu, Hong-dou
    Wu, Jun-zheng
    Shi, Hai-Bin
    BMC GASTROENTEROLOGY, 2020, 20 (01)