Contrast-enhanced endoscopic ultrasonography with galactose microparticles: SHU508 A (Levovist)

被引:58
作者
Bhutani, MS
Hoffman, BJ
vanVelse, A
Hawes, RH
机构
[1] DEPT VET AFFAIRS MED CTR,DAYTON,OH
[2] MED UNIV S CAROLINA,CHARLESTON,SC 29425
关键词
D O I
10.1055/s-2007-1004270
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Study Aims: To evaluate the utility of a suspension of galactose microparticles available as SHU508A (Levovist) as a contrast agent during endoscopic ultrasonography (EUS). Materials and Methods: Three sets of experiments were performed on three 20-25 kg swine (Sus scrofa) under general anesthesia, Upper EUS was performed with an echo endoscope with color Doppler capability (Pentax FG-32 UA), The celiac artery, superior mesenteric artery, aorta, portal vein, pancreas, and gastrointestinal wall were imaged by EUS, Multiple intravenous bolus injections of 400 mg/ml of SHU508A were made, and their effect on color Doppler and gray-scale imaging during EUS was studied. Results: After contrast injection there was a significant, visually noticeable enhancement of the color Doppler signals from the celiac artery, superior mesenteric artery, and portal vein, Vessels with weak to no color Doppler signals before injection of SHU508 A for example, the celiac artery and superior mesenteric artery were observed to have strong color signals after injection, The effect of SHU508 A on color Doppler imaging was easily appreciated subjectively without the need for complex quantitative measurements, No visually noticeable color Doppler enhancement was seen in vessels such as the aorta that had a very pronounced color Doppler signal even prior to the injection of contrast, Movement of particulate matter was seen in the portal vein on the gray scale. Conclusion: Intravenous SHU508 A as a contrast agent significantly enhances color Doppler signals during EUS, Vascular contrast of this sort could potentially have a significant role in improving the accuracy of EUS in diagnosing malignant vascular invasion, the detection of occult pancreatic neoplasms, and the diagnosis of vascular thrombosis.
引用
收藏
页码:635 / 639
页数:5
相关论文
共 35 条
  • [31] DOPPLER COLOR FLOW IMAGING IN THE DETECTION AND QUANTITATIVE MEASUREMENT OF THE GASTRODUODENAL ARTERY BLOOD-FLOW
    UZAWA, M
    KARASAWA, E
    SUGIURA, N
    SAOTOME, N
    KITA, K
    FUKUDA, H
    MIKI, M
    TOGAWA, Y
    KONDOU, F
    MATSUTANI, S
    OHTO, M
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1993, 21 (01) : 9 - 17
  • [32] Vilmann P, 1996, GASTROINTEST ENDOSC, V43, P238
  • [33] ENDOSONOGRAPHY-GUIDED REAL-TIME FINE-NEEDLE ASPIRATION BIOPSY
    WIERSEMA, MJ
    KOCHMAN, ML
    CRAMER, HM
    TAO, LC
    WIERSEMA, LM
    [J]. GASTROINTESTINAL ENDOSCOPY, 1994, 40 (06) : 700 - 707
  • [34] Insulinoma: Finding the needle in a haystack
    Wiersema, MJ
    [J]. ENDOSCOPY, 1996, 28 (03) : 310 - 311
  • [35] YASUDA K, 1984, SCAND J GASTROENTERO, V19, P9